Medium and high evaporating temperature condensing units for walk-in coolers, chiller rooms, refrigerated display cabinets, and beverage coolers.
Speedway Refrigeration manufactures HBP MBP condensing units in China, with refrigerant options including R404/507/448/449/290, depending on the model. Share your application, required cooling capacity, design evaporating temperature, ambient temperature, and power supply with our engineers to get a suitable unit selection and quotation.
HBP stands for High Back Pressure and covers higher evaporating temperatures, such as beverage coolers and refrigerated display cabinets. MBP stands for Medium Back Pressure and covers medium evaporating temperatures, such as walk-in coolers and chiller rooms. The exact operating range depends on the unit model, refrigerant, and refrigeration system.
| Selection | HBP — High Back Pressure | MBP — Medium Back Pressure |
|---|---|---|
| Evaporating temperature | −5°C to +15°C (23°F to 59°F) | −20°C to 0°C (−4°F to 32°F) |
| Applications | Beverage coolers, refrigerated display cabinets, and liquid cooling | Walk-in coolers, chiller rooms, and chilled goods storage |
| Capacity change from 25°C to 38°C ambient | About 16.3% lower at +5°C evaporating temperature | About 17.1% lower at −10°C evaporating temperature |
| Checklist when selecting a unit | Cooling capacity at the design point and compressor operating limits at higher suction pressures | Cooling capacity at the cooler design point and evaporator sizing |
Notice: The typical ranges overlap from −5°C to 0°C (23°F to 32°F). Use the project’s design evaporating temperature to read the performance table. Then check the specific condensing unit’s operating range and cooling capacity at your design ambient temperature and refrigerant.
For Chiller room and Walk-in chiller HBP Application
Model Range: Hermetic condensing unit
Compressor Series: Inverter rotary / scroll compressor
Horsepower Range: 4HP ~ 10HP
Evaporating Temperature: -5°C ~ +15°C
Application: HBP
Room Temperature Range: 0°C ~ +10°C
Ambient Temperature: Up to +42°C
Voltage: 220V / 380V
Power Supply: 1Ph / 3Ph, 50Hz / 60Hz
Refrigerants: R290 / R404 / R448 / R449
Condenser Type: Air cooled finned copper coil condenser
Control Option: LED digital controller
Defrost Matching: Electric defrost or Hot gas defrost
For Refrigerated Cabnet and Chiller Room MBP Application
Model Range: Inverter condensing unit
Compressor Series: Inverter rotary / scroll compressor
Horsepower Range: 2HP ~ 5HP
Evaporating Temperature: +5°C ~ -15°C
Application: MBP
Room Temperature Range: 0°C ~ -10°C
Ambient Temperature: Up to +43°C
Voltage: 220V
Power Supply: 1Ph / 3Ph, 50Hz / 60Hz
Refrigerants: R290 / R404 / R448 / R449
Condenser Type: Air cooled finned copper coil condenser
Control Option: LED digital controller
Defrost Matching: Electric defrost or Hot gas defrost
For Walk-in Cooler, Beverage cooler and Chiller Room HBP MBP Application
Model Range: Box type condensing unit
Compressor Series: Non-inverter rotary / scroll compressor
Horsepower Range: 8HP ~ 45HP
Evaporating Temperature: +10°C ~ -20°C
Application: HBP, MBP
Room Temperature Range: +5°C ~ -18°C
Ambient Temperature: Up to +45°C
Voltage: 220V / 380V
Power Supply: 1Ph / 3Ph, 50Hz / 60Hz
Refrigerants: R290 / R404 / R448 / R449
Condenser Type: Air cooled finned copper coil condenser
Control Option: LED digital controller
Defrost Matching: Electric defrost or Hot gas defrost
For Walk-in cooler and Chiller Room HBP MBP Application
Model Range: H type condensing unit
Compressor Series: Non-inverter rotary / scroll compressor
Horsepower Range: 3HP ~ 20HP
Evaporating Temperature: +5°C ~ -20°C
Application: HBP, MBP
Room Temperature Range: +0°C ~ -15°C
Ambient Temperature: Up to +43°C
Voltage: 220V / 380V
Power Supply: 1Ph / 3Ph, 50Hz / 60Hz
Refrigerants: R290 / R404 / R448 / R449
Condenser Type: Air cooled finned copper coil condenser
Control Option: LED digital controller
Defrost Matching: Electric defrost or Hot gas defrost
For Chiller room and Walk-in chiller HBP Application
Model Range: Semi-hermetic condensing unit
Compressor Series: Non-inverter scroll compressor
Horsepower Range: 2HP ~ 40HP
Evaporating Temperature: +15°C ~ -5°C
Application: HBP
Room Temperature Range: 0°C ~ +15°C
Ambient Temperature: Up to +45°C
Voltage: 220V / 380V
Power Supply: 1Ph / 3Ph, 50Hz / 60Hz
Refrigerants: R290 / R404 / R448 / R449
Condenser Type: Air cooled finned copper coil condenser
Control Option: LED digital controller
Defrost Matching: Electric defrost or Hot gas defrost
For Refrigerated cooler room and Walk-in chiller HBP MBP Application
Model Range: V Type condensing unit
Compressor Series: Non-inverter scroll compressor
Horsepower Range: 5HP ~ 45HP
Evaporating Temperature: +10°C ~ -20°C
Application: HBP, MBP
Room Temperature Range: +10°C ~ -18°C
Ambient Temperature: Up to +45°C
Voltage: 380V
Power Supply: 3Ph, 50Hz / 60Hz
Refrigerants: R290 / R404 / R448 / R449
Condenser Type: Air cooled finned copper coil condenser
Control Option: LED digital controller
Defrost Matching: Electric defrost or Hot gas defrost
Speedway supplies HBP and MBP condensing units for walk-in coolers, chiller rooms, refrigerated display cabinets, beverage coolers, and chilled storage warehouses.
Walk-In Coolers and Chiller Rooms | MBP
MBP units suit fresh produce, dairy, and chilled food storage in supermarkets and foodservice facilities. Size the unit for the cooling load from incoming products, frequent door openings, and daily operating conditions.
Refrigerated Display Cabinets and Beverage Coolers | HBP or MBP
HBP and MBP units serve beverage coolers and chilled display cabinets, depending on the design evaporating temperature. Check cooling capacity, compressor operating limits, and condenser ventilation for the cabinet’s installation conditions.
Chilled Warehouses and Distribution Centers | MBP
MBP units support chilled goods storage and distribution. Calculate each zone’s cooling load, account for product deliveries and loading activity, and check simultaneous demand when multiple evaporators share a refrigeration system.
Select models faster by temperature range, project type, and application.
Choose standard models for regular orders or OEM options for custom projects.
Adjust cooling output more smoothly under changing room load.
Improve operating efficiency when the cold room doesn’t run at full load.
Match local voltage, phase, and frequency for different export markets.
Handle hot climate projects with suitable high ambient systems.
Use energy-saving Copeland/Sanyo/Highly compressor, to save you bill forever
We understand your market and match refrigeration equipment to local operating conditions and customer requirements.
High-efficiency Cold Room Condenser
Speedway cold room condenser copper coil combines durable copper tubing with precision-formed aluminum fins. Uniform fin spacing promotes even airflow, while tight contact between the tubes and fins ensures efficient heat transfer (30% higher than other suppleirs) and reliable heat rejection.
Embraco/Bitzer/Copeland/Dorin Compressor
We offer world famous compressor options for HBP and MBP condensing units, and match each compressor to the required cooling capacity, refrigerant, evaporating temperature, and ambient conditions to support reliable operation.
Solid Condensing Unit Casing
Speedway rigid casing protects key components during handling and installation. Secure mounting points hold the compressor and condenser copper coil in position, while removable panels give technicians direct access for inspection and routine maintenance.
Cold Room Evaporators in Multiple Sizes
Speedway offer evaporators with fan diameters from 300 to 800 mm and fin spacing from 4 to 16 mm. We match copper coil capacity and airflow to the cooling load and operating temperature of each walk-in cooler or chiller room.
Smart Inverter Board with Self-Diagnostics
Speedway inverter board adjusts compressor speed to match cooling demand and monitors operating conditions in real time. Its self-diagnostics flag faults, helping technicians troubleshoot during commissioning and reduce downtime during service.
Accurate Temp Control
Our thermostat monitors cold room temperature and regulates cooling around the selected setpoint. This precise control limits temperature fluctuations and helps maintain stable conditions for both chilled and frozen products.
Speedway technicians assemble the refrigerant circuit and electrical controls, then inspect brazed joints, wiring connections, and component mounts. Before shipment, we conduct pressure hold tests and leak checks to verify refrigerant circuit integrity. We run the units to confirm compressor, fan, and control operation, then secure them for handling and transport.
Keep Pressure and Anti-leak
Packed Condensing Unit-Ready to Ship
Condensing Unit Parameter Test at Pre-shipment
1.Enhanced Vapor Injection
Enhanced Vapor Injection(EVI) use plate heat exchanger subcools the liquid refrigerant in the main circuit while vaporizing refrigerant in a separate branch. The resulting intermediate-pressure vapor enters the compressor through a dedicated injection port.
In cold rooms, EVI increases cooling capacity at low evaporating temperatures, making it particularly suitable for walk-in freezers. It can also improve energy efficiency when the unit matches the operating conditions.
2.Variable-Speed Compressor
Speedway inverter condensing units automatically adjust compressor speed to match the cold room’s cooling load. After large deliveries or frequent door openings, they can increase cooling output to help the room return to its setpoint faster. At lower loads, they can run at reduced speed to reduce on/off cycling, limit temperature fluctuations, and cut part-load energy use.
3.High-Ambient Performance
We match the condenser and fans to maintain effective heat rejection in hot weather. Select models operate at outdoor ambient temperatures up to 50 °C. We size each unit for the project’s peak outdoor temperature to help maintain the target cold room temperature during the hottest periods.
4.Hot Gas Defrost
Hot gas defrost is a method that directs hot refrigerant vapor from the compressor discharge through the evaporator coil to melt frost on the coil surface. Speedway condensing units use hot refrigerant vapor from the compressor to warm the evaporator coil from within and melt frost, reducing reliance on electric coil heaters. When we match the condensing unit to the evaporator, hot gas defrost can shorten cooling interruptions, restore airflow and cooling sooner, and limit the rise in cold room temperature during defrost.
HBP stands for High Back Pressure and covers higher evaporating temperatures. MBP stands for Medium Back Pressure and serves medium-temperature refrigeration. Select a unit by its operating range, refrigerant, and cooling capacity at your design conditions.
HBP units serve applications such as beverage cooling, refrigerated display cabinets, and liquid cooling. MBP units commonly serve walk-in coolers, chiller rooms, and chilled warehouses. Some applications overlap, so confirm the required evaporating temperature before selecting a model.
No. Room temperature provides a starting point. Also confirm the design evaporating temperature, cooling load, and peak ambient temperature. The evaporator’s temperature difference and the product’s humidity requirements also influence unit selection.
Yes, when the compressor’s operating range covers both duty points. Check cooling capacity and power consumption at each point using the project’s refrigerant, evaporating temperature, and ambient temperature.
Start with the calculated cooling load in kW. Share the target temperature, insulation thickness, product load, door-opening frequency, and ambient conditions. Our engineers use these details to select a unit that meets the project’s cooling demand.
Refrigerant options depend on the compressor and unit model, can choose from R404/507/448/449/290 and more.
YES.A suitable system can serve multiple evaporators when its capacity, piping, and controls match the application. Share each evaporator’s cooling load, operating temperature, and usage schedule so our engineers can review simultaneous demand and capacity control.
We offer standard and OEM refrigeration system. Share your destination market, voltage, phase, frequency, and any limits on cold room size or connection location. For repeat orders, ask us to confirm the model code and component list so you can re-order the same system.
Q9.Yes. Send the evaporator model, performance sheet, refrigerant, and expansion valve details. We check capacity at the same design evaporating temperature and review airflow, refrigerant control, and defrost requirements for your application.
Consider how much the cooling load changes during operation. Inverter units adjust compressor speed as demand changes. Non-inverter units use on/off control. Compare capacity, part-load operation, controls, and service requirements for your project.
Partner with us to increase your brand reputation, get an impressive experience for your clients to remember you lifelong, and help you stand out in the competitive market !
Correct calculation can reduce your cold room budget
Note: Preliminary reference only. Consult a professional for final design.
We customize the superior refrigeration products based on your idea or suggestion since 2010