We produce most types of cold room door with custom sizes, thickness, and materials. Door thickness: 75/100/120/150/200mm or customize.
Cold room door (Also called cold storage door) refers to a door that installed in a freezing environment such as freezer or chiller for thermal insulation and airtightness.
Cold Room insulation design is mainly to block the heat transfer between the cold room and outside. High-quality cold room door will greatly enhance the thermal insulation effect of the cold room. And generally coordinate with air curtains, cold room door can effectively reduce the cooling loss of cold room.
Automatic Sliding Door
Never Flammable Door (PU Core)
There are 2 methods to produce cold room door core:
#1. Polyurethane (PU) Injection
Use PU pressure injection molding machine to produce. The polyurethane structure is dense, no shrink, and the door is smooth and beautiful.
#2. Thermal Insulation Panel
PU thermal insulation panel not only has a high strength but also has good thermal insulation effect; There is a safety device on the cold room door to escape easily once people are accidentally closed in the cold room.
Both sides skin uses stainless steel, color steel, alluminum alloy,etc.
The guide rails are made of rust-proof aluminum alloy, and have an anti-icing system. All screws are galvanized, with 2.0mm thickness stainless steel (or custom your material) edge seamless welded door frame, durable and non-deformation.
Guide Rail
Door Frame
Screw
Door Press
Door Opener
Door Escape Device
Cold room door mainly used for cold chain logistics, food processing, shopping malls, supermarkets, hotels and aviation catering, biopharmaceuticals, fine chemicals, precision electronics and other industries. Meanwhile, used for the production, storage and logistics of food, medicine and other commodities that require a constant temperature environment.
Sea Food
Cold Chain
Supermarket
Aviation Catering
Biomedicine
Fine Chemicals
Food Processing
Precision Electronics
Temperature range: +10°C to -30°C.
Door thickness: 50/75/100/120/150 mm.
Opening method: Manual sliding.
Recommended for: Medium and large cold rooms, food processing rooms, freezer rooms, and back-of-house storage.
Opening frequency: Max 10–30 openings per day.
Size range: Custom sizes for wider clear openings and pallet access.
Optional features: Vision window, heater wire, escape release, stainless steel cladding, kick plate.
Not recommended for: Very high-traffic areas or projects that need automatic opening.
Temperature range: +10°C to -35°C.
Door thickness: 50/75/100/120/150 mm.
Opening method: Manual sliding.
Recommended for: Food factories, hospitality cold rooms, pharmaceutical rooms, and work areas that need visibility.
Opening frequency: Max 10–30 openings per day.
Size range: Custom sizes for personnel and pallet movement.
Optional features: Heated window, anti-fog glass, heater wire, internal escape device, stainless steel surface.
Not recommended for: High-frequency access points or unmanned operation areas.
Temperature range: +10°C to -35°C.
Door thickness: 50/75/100/120/150 mm.
Opening method: Electric sliding.
Power Supply: 220~240V 50/60Hz, 380~440V 50/60Hz
Recommended for: Forklift traffic, busy cold rooms, distribution centers, seafood processing, and central kitchens.
Opening frequency: Max 30–80 openings per day.
Size range: Custom large openings for carts, pallets, and forklifts.
Optional features: Double leaf, remote control, anti-fog window, safety sensor, warning light, heater wire, manual release.
Not recommended for: Small cold rooms with low daily usage or sites with limited power supply.
Temperature range: +10°C to -25°C.
Door thickness: 50/75/100/120/150/200 mm.
Opening method: Hinged.
Recommended for: Small cold rooms, dairy rooms, hotel cold storage, fruit and vegetable rooms, and pharmaceutical support rooms.
Opening frequency: Up to 10 openings per day.
Size range: Best for standard personnel door openings.
Optional features: Door closer, vision panel, heater frame, stainless steel hardware, single or double leaf.
Not recommended for: Wide openings, forklift routes, or high-frequency access areas.
Temperature range: +10°C to -25°C.
Door thickness: 50/75/100/120/150/200 mm.
Opening method: Hinged.
Recommended for: Clean-looking installations, integrated wall finishes, and standard personnel access areas.
Opening frequency: Up to 10 openings per day.
Size range: Standard and custom personnel access sizes.
Optional features: Stainless steel frame, door closer, vision window, heater, double leaf configuration.
Not recommended for: Large openings, forklift traffic, or heavy industrial use.
Temperature range: +15°C to -25°C
Opening method: High-speed rolling.
Power Supply: 220~240V 50/60Hz, 380~440V 50/60Hz
Recommended for: Distribution centers, supermarket backrooms, production transfer zones, and frequent in-and-out passages.
Opening frequency: Max 80+ openings per day.
Size range: Custom sizes for people, carts, and forklift passage.
Optional features: Radar sensor, geomagnetic loop, remote control, impact-resistant curtain, safety photo eye.
Not recommended for: Deep-freeze rooms that need thick insulated door leaves, especially blast freezer applications.
Due to the temperature difference between inside and outside of the cold room, when open the door, the hot air passes through the gap to generate strong convection, resulting in cooling loss.
The amount of hot air entering the cold room is related to the height and width of the door, the temperature difference between inside and outside of the room, and of course the time and frequency of opening the door.
You should select a cold room door which opens and closes quickly, meanwhile had better set an air curtain.
#1. Select according to the temperature
If you choose a thinner thickness door for low-temperature cold room, it won’t achieve the ideal insulation effect, but will frost the door, and damage the door.
Chiller temperature is -15℃~+10℃, you can choose 100mm (10cm) thickness door; Freezer is -30 ~ -15℃, choose 150mm (15cm) thickness door; Blast freezer is -30℃~-45℃, you should choose 200mm (20cm) thickness door.
According to the temperature difference, the cold room door thickness can select from 50, 75, 100, 120, 150, 200, 250 mm.
#2. Select according to size
The cold room door size is not fixed, can be made of various sizes according to custom requirements. It can be divided into manual or electric one-leaf, double-leaves sliding door or hinged door, please choose the appropriate size and type of cold room door according to cold room application.
For example, if need forklift to enter and exit, you should choose an electric cold room door to facilitate entry and exit. For small cold room, only few people enter and exit, so can choose manually operate door.
Meanwhile, when installation, you must also understand the specific location of the cold room door. If choosing a sliding door, you need to have enough space to place the slide.
#3. Select according to the material
The cold room door frame can be made of aluminum alloy, stainless steel, color steel or PVC plastic. PVC is a poor conductor of heat, which can’t only effectively ensure a constant temperature, but also strengthen the load-bearing capacity of the door frame and guide rails. It can still be used at low temperatures.
Cold room door wrapping adopts stainless steel seamless welding or glass fiber reinforced plastic (FRP) which is impermeable, strong heat insulation and corrosion resistance.
The inner core of cold room door is generally made of polyurethane (PU) , PIR, or XPS material. XPS has good moisture resistance, high compressive strength, moderate price, stable performance and long service life. It is the best choice for cold room insulation materials.
| Project Condition | Hinged Door | Manual Sliding Door | Industrial Sliding Door with Window | Electric Sliding Door | Rolling Door |
|---|---|---|---|---|---|
| Temperature range: +10°C to -5°C | Yes | Yes | Yes | Yes | Yes |
| Temperature range: -5°C to -25°C | Yes | Yes | Yes | Yes | Yes |
| Temperature range: -25°C to -45°C | No | Best | Best | Best | No |
| Opening frequency: Up to 10 openings per day | Best | Yes | Yes | Yes | No |
| Opening frequency: 10–30 openings per day | No | Best | Best | Yes | Yes |
| Opening frequency: 30–80 openings per day | No | No | No | Best | Yes |
| Opening frequency: 80+ openings per day | No | No | No | Yes | Best |
| Forklift traffic | No | Yes | Yes | Best | Best |
| Personnel traffic only | Best | Yes | Yes | Yes | Yes |
| Small door opening | Best | Yes | Yes | Yes | No |
| Medium door opening | Yes | Best | Best | Best | Yes |
| Large door opening | No | Best | Best | Best | Best |
| Humid environment / icing risk | Yes | Yes | Yes | Yes | Yes |
| Clean or hygiene-sensitive area | Yes | Yes | Best | Yes | No |
| Need visibility through the door | Yes | Yes | Best | Best | No |
| Need automatic opening | No | No | No | Best | Best |
| Need lower equipment cost | Best | Best | Yes | No | No |
| Need faster traffic flow | No | Yes | Yes | Best | Best |
| Component name | Characteristics |
|---|---|
| Door panel | Completely enclosed frame-free structure, polyurethane and panel whole foaming, panel is made of color steel, stainless steel or aluminum sheet, has good thermal insulation performance. |
| Door frame | Made of aluminum alloy or C-shape steel covered by stainless steel, tidy appearance and durable, not like wooden door frame which is easy corrosion. |
| Guide rail device | Made of aluminum alloy, its guides wheel device acts together with compression wheel so that the door can separate with door frame when opening and press against door frame and floor when closing. |
| Electric control system | Adopt turbine-worn reducer and synchronous belt to transfer the movement. Meanwhile, has electromagnetic clutch to automatically realize the conversion between pad and manual, which ensures the safety of the electric door. |
| Sealing stripe | Low temp resistance, oil resistance, made of high elastic EPDM, ambient temp: -50°C ~ +130 °C can work properly. |
| Heating wire | Automatic constant temp, 220V or 36V, low voltage heating. |
| Fittings | Metal parts of door panel are of high precision stainless steel. |
| Door thickness | 75/100/150/200mm |
| Component name | Characteristics |
|---|---|
| Door panel | Stainless steel/aluminum/steel material and panel combine to the casing, with integrated foaming of polyurethane, without Cold bridge phenomenon, extremely good heat preservation performance. |
| Door frame | Has electric heating stripe for self-temperature control, no need temperature control device or manual switch power source. |
| Sealing stripe | Flexiable plastic built-in magnetic stripes, can modify even small error caused by fabrication. |
| Escape device | With escape and safety devices, and also has internal handle. |
| Fittings | Use stainless steel or high strength Zinc alloy material. |
| Door thickness | 50/75/100/150/200mm |
| Information Needed | What to Provide |
|---|---|
| Opening size | Width × height of the clear opening |
| Room temperature | Chiller, freezer, or exact working temperature |
| Door type | Hinged, manual sliding, electric sliding, or rolling door |
| Operation type | Manual or electric |
| Skin material | Color steel, stainless steel, aluminum, or other |
| Project country | Installation country or destination market |
| Quantity | Required number of doors |
We build doors to match your size, material, and project requirements.
We inspect materials, assembly, and finished products before shipment.
We match door thickness to chiller, freezer, and blast freezer applications.
We review your requirements and quote with clear product specifications in 24 hours.
We offer multiple door types for different temperature and traffic conditions.
We support branded production and flexible customization for distributors and contractors.
We help with model selection, drawings, and installation-related questions.
We support spare parts, technical questions, and repeat project requirements.
Frequently Asked Questions About Cold Room Door
Choose the door by room temperature, opening frequency, traffic type, opening size, and automation needs. Hinged doors fit small low-use rooms, sliding doors fit wider openings, and electric or rolling doors fit frequent traffic.
Match door thickness to the working temperature. Chiller rooms usually use 50/75/100 mm thickness doors, freezer rooms need 100/150/200 mm thickness doors, and blast freezer projects often require heavier door structures.
Speedway is committed to quality across all aspects of our business – our people, processes and products. We call this ‘SPEEDWAY standard’.
Choose a hinged door for small openings and low daily use. Choose a sliding door for wider openings, better sealing, and easier access for carts or forklifts.
We welcome any sample order before big quantity purchase, that means 1pc is acceptable. For mass order quantity is 20pcs for total.
Choose an electric door when the door opens frequently, when forklifts pass through, or when you need faster and easier operation. Electric doors also help improve workflow in busy cold room areas.
Yes. We support custom opening sizes, door thickness, surface materials, hardware, windows, and optional safety features to match different project requirements.
We have own factory to produce the main cold room door products, but we also do trading for other related products because we have resource to supply good quality and service.
Yes,we have 3 senior engineers, 10 professional r & D team, 55 professional production personnel.
Send your opening size, room temperature, preferred door type, manual or electric option, surface material, quantity, and project country. Clear project details help us recommend the right model and quote faster.
You can add vision windows, heater wire, escape release, anti-fog glass, door closers, safety sensors, radar opening, and other project-based options. We match the system to your application and operating conditions.
We support payment through wire transfer, like T/T, L/C, Western Union. Also accpet Paypal payment for sample piece order.
Yes. We support product selection, drawings, technical questions, and spare parts service. We help buyers, installers, and contractors solve project issues more efficiently.
First, we need starting the business to understand each other, if things move smoothly and you meet our “distributor request”, then we will sign the formal contract and agreement to ensure your rights in your market.
Contact our salesman for more details please.
Partner with us to increase your brand reputation, get an impressive experience for your clients to remember you lifelong, and help you stand out in the competitive market !
We customize the superior refrigeration products based on your idea or suggestion since 2010