What is inverter condensing unit?

Condensing Unit

Inverter condensing unit uses variable-speed control to adjust compressor output based on the actual cooling load.
Instead of running at one fixed speed all the time, it changes capacity as room demand changes.

This helps the system keep room temperature more stable, reduce frequent start-stop cycles, and improve efficiency during part-load operation.
It works especially well in cold rooms with changing load, frequent door opening, day-night temperature swings, or strict temperature control needs.

Use Inverter Condensing Unit or Not?

Inverter condensing units work best in projects with changing load, long daily running hours, or higher temperature control requirements.
They don’t fit every cold room project, so correct selection matters.

Suitable ApplicationsWhy It FitsLess Suitable ApplicationsWhy It Not Fit
Cold rooms with frequent door openingLoad changes often during the day, so inverter compressor helps the unit adjust fasterProjects with very stable load all dayA non-inverter unit can offer a simpler solution
Fresh produce storageBetter temperature stability helps protect product qualityProjects with very tight initial budgetThe buyer may focus more on first cost than operating efficiency
Food processing roomsRoom load changes with workflow, people, and door trafficSimple replacement jobs with limited control upgradeThe site may not support the full value of inverter system
Distribution and logistics cold roomsThe system often faces variable cooling demandRemote areas with weak service supportBuyers may prefer simpler components and easier service
Multi-purpose cold roomsDifferent products and room use can create fluctuating demandSmall projects with short daily running timeEnergy-saving return may not be strong enough
Projects with high electricity costBetter part-load performance can improve operating costBuyers who want only the lowest purchase priceProduct value may not match the buying target
Projects that require lower noiseInverter operation can reduce noise under part-load conditionsProjects with fixed operating condition and simple control targetThe system may not need variable capacity control
Projects that need tighter temperature controlThe unit can adjust capacity more smoothlySites with unstable power quality and no proper protection planThe project may need extra electrical review before selection

Why Choose Our Inverter Series?

Select models faster by temperature range, project type, and application.

Choose standard models for regular orders or OEM options for custom projects.

Adjust cooling output more smoothly under changing room load.

Improve operating efficiency when the cold room doesn’t run at full load.

Match local voltage, phase, and frequency for different export markets.

Handle hot climate projects with suitable high ambient systems.

Match the unit with room temperature, evaporator, and site condition more easily.

Fit the needs of distributors, installers, contractors, and project buyers.

Inverter Condensing Unit Series

Choose the right inverter condensing unit series by room temperature, cooling load, ambient condition, refrigerant, and project type.
A correct selection helps you balance temperature, energy performance, installation cost, and long-term service support.

High Temp Inverter Unit

For applications that need stable cooling in the 0°C to +15°C range.

ModelHPRoom TempRefrigerantPower SupplyKey AdvantageSuitable For
SWICDU2H2HP+5°C to +15°CR290/R404A220V/1Ph/50/60HzCompact size, low noiseBeverage room, flower room
SWICDU3H3HP+2°C to +12°CR290/R404A220V/1Ph/50/60HzStable temperature controlFresh food room, dairy room
SWICDU5H5HP0°C to +10°CR290/R404A380V/3Ph/50/60HzBetter part-load efficiencyProduce room, food prep room
SWICDU8H8HP0°C to +10°CR290/R404A380V/3Ph/50/60HzStronger cooling for larger roomsProcessing room, commercial storage
SWICDU10H10HP0°C to +8°CR290/R404A380V/3Ph/50/60HzGood for long daily operationLarge fresh storage projects
hermetic condensing unit-with logo 1

Basic Parameters

  • Model Range: Inverter condensing unit models

  • Compressor Series: Inverter rotary / scroll compressor 

  • Horsepower Range: 2HP to 10HP

  • Evaporating Temperature: +5°C to -10°C

  • Application Temperature: High temperature 

  • Room Temperature Range: 0°C to +15°C

  • Ambient Temperature: Up to +43°C, high ambient option available

  • Voltage: 220V / 380V

  • Power Supply: 1Ph / 3Ph, 50Hz / 60Hz

  • Refrigerants: R290a / R404A / R448A / R449A

  • Installation Type: Floor mounted / outdoor

  • Unit Type: Air cooled inverter condensing unit

  • Condenser Type: Air cooled finned coil condenser

  • Control Option: LED digital controller

  • Defrost Matching: Electric defrost or Hot gas defrost

  • Dimensions: Depend on compressor HP and condenser size

Medium Temp Inverter Unit

For standard cold room applications in the -10°C to +5°C range.

Model

HPRoom TempRefrigerantPower SupplyKey AdvantageSuitable For
SWICDU2M2HP0°C to +5°CR290/R404A220V/1Ph/50/60HzSmall footprint, easy installationSmall cold room
SWICDU3M3HP-2°C to +5°CR290/R404A220V/1Ph/50/60HzStable operation for daily useConvenience cold room
SWICDU5M5HP-10°C to +5°CR290/R404A380V/3Ph/50/60HzBetter load matchingMeat prep room, produce room
SWICDU8M8HP-10°C to +5°CR290/R404A380V/3Ph/50/60HzHigher efficiency in long-hour useMedium commercial cold room
SWICDU10M10HP-10°C to +5°CR290/R404A380V/3Ph/50/60HzStrong cooling outputLarge cold storage room
SWICDU12M12HP-10°C to +5°CR290/R404A380V/3Ph/50/60HzGood for project matchingFood processing and storage
hermetic condensing unit-with logo

Basic Parameters

  • Model Range: Inverter condensing unit models

  • Compressor Series: Inverter rotary / scroll compressor

  • Horsepower Range: 2HP to 12HP

  • Evaporating Temperature: 0°C to -20°C

  • Application Temperature: Medium temperature

  • Room Temperature Range: -10°C to +5°C

  • Ambient Temperature: Up to +43°C, high ambient option available

  • Voltage: 220V / 380V 

  • Power Supply: 1Ph / 3Ph, 50Hz / 60Hz

  • Refrigerants: R290a / R404A / R448A / R449A

  • Installation Type: Outdoor

  • Unit Type: Air cooled inverter condensing unit

  • Condenser Type: Air cooled finned coil condenser

  • Control Option: LED digital controller

  • Defrost Matching: Electric defrost or hot gas defrost

  • Dimensions: Depend on compressor HP and condenser size

Low Temp Inverter Unit

For freezer rooms and frozen storage in the -18°C to -25°C range.

ModelHPRoom TempRefrigerantPower SupplyKey AdvantageSuitable For
SWICDU3L3HP-18°C to -20°CR404A/R448A380V/3Ph/50/60HzReliable entry model for freezer roomsSmall freezer room
SWICDU5L5HP-18°C to -22°CR404A/R448A380V/3Ph/50/60HzStable low-temp coolingFrozen meat room
SWICDU8L8HP-20°C to -25°CR404A/R448A380V/3Ph/50/60HzBetter performance for heavier loadSeafood freezer room
SWICDU10L10HP-20°C to -25°CR404A/R448A380V/3Ph/50/60HzStronger output for large roomsFrozen food warehouse
SWICDU12L12HP-20°C to -25°CR404A/R448A380V/3Ph/50/60HzGood for long-hour freezer useDistribution freezer room
SWICDU15L15HP-20°C to -25°CR404A/R448A380V/3Ph/50/60HzProject-ready for larger systemsIndustrial cold storage
hermetic condensing unit-with logo 3

Basic Parameters

  • Model Range: Inverter condensing unit models

  • Compressor Series: Inverter scroll compressor

  • Horsepower Range: 3HP to 15HP

  • Evaporating Temperature: -15°C to -35°C

  • Application Temperature: Low temperature

  • Room Temperature Range: -18°C to -25°C

  • Ambient Temperature: Up to +43°C, high ambient option available

  • Voltage: 380V / 415V / 460V

  • Power Supply: 3Ph, 50Hz / 60Hz

  • Refrigerants: R404A / R507 / R448A / R449A

  • Installation Type: Outdoor

  • Unit Type: Air cooled inverter condensing unit

  • Condenser Type: Air cooled finned coil condenser

  • Control Option: LED digital controller

  • Defrost Matching: Electric defrost or hot gas defrost

  • Dimensions: Depend on compressor HP and condenser size

OEM Inverter Unit

For buyers who need custom system and project, brand labeling, or project-based design.

ModelHPRoom TempRefrigerantPower SupplyKey AdvantageSuitable For
SWICDU3O3HPHigh/medium/lowR290/R404A/CustomCustomFlexible entry OEM optionLocal distributors
SWICDU5O5HP High/medium/lowR290/R404A/CustomCustomGood for repeat OEM ordersBrand owners
SWICDU8O8HP High/medium/lowR290/R404A/CustomCustomBetter for project matchingContractors
SWICDU10O10HP High/medium/lowR290/R404A/CustomCustomSupports more configuration optionsCold room builders
SWICDU12O12HP High/medium/lowR290/R404A/CustomCustomGood for engineering projectsProject contractors
SWICDU15O15HP High/medium/lowR290/R404A/CustomCustomSuitable for larger OEM demandIndustrial buyers
semi-hermetic condensing unit 04

Basic Parameters

  • Model Range: OEM inverter condensing unit models

  • Compressor Series: Inverter piston/scroll compressor

  • Horsepower Range: 3HP to 15HP

  • Evaporating Temperature: +5°C to -35°C

  • Application Temperature: High  / medium / low temperature

  • Room Temperature Range: Custom

  • Ambient Temperature: Up to +43°C, high ambient option available

  • Voltage: 220V / 380V / 415V / 460V

  • Power Supply: 1Ph / 3Ph, 50Hz / 60Hz

  • Refrigerants: R290a / R404A / R448A / R449A

  • Installation Type: Floor mounted 

  • Unit Type: Air cooled inverter condensing unit

  • Condenser Type: Air cooled finned coil condenser

  • Control Option: LED digital controller

  • Defrost Matching: Electric defrost or hot gas defrost

  • Dimensions: Depend on compressor HP and condenser size

Find the right inverter condensing unit for your project

By Room Temperature

  • Chiller Room: 0°C to +10°C, for produce, dairy, beverages, and fresh storage

  • Freezer Room: -18°C to -15°C, for frozen food, meat, and seafood

  • Deep Freezer Room: -25°C to -35°C, for deep frozen products and long-term low-temperature storage

By Cooling Method

  • Air-Cooled: easy installation, practical for most standard cold room projects

  • Water-Cooled: better fit for hot climates and indoor mechanical rooms

  • Evaporative Type: stronger heat rejection for larger and more demanding projects

By Structure

  • Open Type (Semi-hermetic): easier service access for project installations

  • Box Type: compact cabinet design for outdoor use and better protection

  • Compact Outdoor Type: space-saving layout for standard cold room applications

By Refrigerant

  • R404A: for many low-temperature and replacement applications

  • R448A / R449A: for compliance-focused and retrofit projects

  • Other Options: available for selected markets and project needs

By Buyer Type

  • For Distributors: standard models, OEM branding, spare parts planning

  • For Installers: easier matching, wiring, and commissioning

  • For Contractors: flexible project configuration and technical support

  • For OEM Buyers: stable specification, custom labeling, and repeat production

Custom Condensing Unit

Excellent Energy-Save Condensing Unit

Inverter condensing unit can save max 50% energy and cooling time, most suitable for voltage un-stable area, never damage compressor

Inverter CDU

Condensing Unit Inverter Board

Custom Display

Custom Display Board

Unique Design 5HP Inverter Board

Superior Inverter Drive Board

Custom Inveter Board

Custom Inverter Main Board

Sight Glass

Sight Glass

Filter Drier 1

Filter Dryer

Oil Separator 1

Oil Separator

Expansion Valve 1

Danfoss TXV Valve

Our Inverter Condensing Unit Unique Features

DesignValues
High efficiency oil separator and precise oil return capillaryReduce the amount of compressor refrigerant oil entering the refrigeration system in-order-to improve refrigeration efficiency, avoid oil-deficient operation, ensure lifetime of compressor and protect compressor safety
Dual electronic expansion valveFast adjustment response, precise storage temperature control, and high temperature protection to ensure compressor optimal operating state
Gas-Liquid SeparatorAvoid liquid refrigerant entering the compression chamber and damage compressor when the ambient temperature and cold storage temperature are low
High-precision sensorAdapt different working conditions of high or low temperature or different items stored, with temperature control accuracy of ±0.5℃
High and low pressure sensorMonitor compressor operation to effectively avoid compressor overload while ensuring the optimal compressor and refrigeration status under any conditions, and adaptively adjust the compressor and motor speed operating parameters according to the refrigerant evaporation efficiency
CFD air duct design 480㎜ diameter fanLow noise, large air volume, high heat exchange efficiency
Brushless DC Motor with Stepless Speed ControlMore energy-saving, more precise load control of the inverter unit, automatic adjustment of the speed according to load demand to ensure optimal condensing efficiency and increase cooling capacity
Display board can customize your company informationCustomize the information based on your demand, help customers improve their market visibility, and make potential customers easier to find your company information
Special low back pressure (LBP) low temperature inverter compressorHigh compression ratio can ensure durability, and guarantee the whole unit durable and stable under high ambient temperature and low storage temperature or low ambient temperature and low storage temperature conditions
Diaphragm single-way check valve designWhen cold room reaches the set temperature, prevent refrigerant in the condenser flowing back into compressor and causing liquid slug to damage the compressor when it starts again

Information Required for Quotation

To get a fast and accurate quotation, please share the following project information:

Information NeededWhat the Customer Should ProvideWhy It Matters
Room SizeLength, width, and height of the cold roomWe use this to estimate the cooling load and select a suitable capacity model.
Room TemperatureTarget room temperature, such as +5°C, -18°C, or -25°CThis helps us choose the right series and operating range.
Product TypeWhat the room will store, such as vegetables, meat, seafood, dairy, or frozen foodDifferent products need different storage conditions and cooling demand.
Ambient TemperatureLocal outdoor temperature or summer design temperature, for example, some Middle east countries max outdoor temp +50°C in summerThis helps us confirm condenser performance and model suitability.
Power SupplyVoltage, phase, and frequency, such as 220V/1Ph 50/60Hz or 380V/3Ph 50/60HzWe need this to match the unit with local electrical standards.
Refrigerant RequirementPreferred refrigerant, if any, such as R290, R404A, R448A, R507, or R449AThis helps us match local regulations and project requirements.
Installation LocationIndoor or outdoor installation, and project country or regionThis affects unit configuration, protection level, and market requirements.
Application TypeNew project, replacement project, distributor order, or OEM orderThis helps us recommend the right configuration and support scope.
Evaporator InformationExisting evaporator model or required matching, if availableThis helps us check system compatibility and avoid mismatch.
Special RequirementsHigh ambient option, anti-corrosion coating, custom branding, special voltage, or controller requirement, etcThis helps us prepare a more accurate quotation and solution.

FAQs

Please send us your room size, room temperature, product type, ambient temperature, power supply, and installation condition. If you have drawings or BOQ (Bill of Quantity), you can send them with your inquiry. Our team can recommend a suitable series and model based on your project.

High temp series usually fits applications from 0°C to +15°C. Medium temp series usually fits applications from -10°C to +5°C. Low temp series usually fits freezer room applications from -18°C to -25°C. If you are not sure which series fits your project, send us your room temperature and use case.

Yes. Inverter condensing units can work well in freezer room applications when the model matches the required room temperature, refrigerant, and cooling load. Low temp series usually suits frozen food, meat, and seafood storage projects.

Not in every project. Energy performance depends on room insulation, evaporator selection, ambient condition, control setting, door opening frequency, and daily load changes. Inverter units usually show more value in projects with variable load and long daily running hours.

Yes. We can select a matching solution based on evaporator model, room temperature, refrigerant, and project condition. This helps reduce capacity mismatch and supports more stable system performance.

Yes, in many cases. But we need to check refrigerant, room temperature, evaporator model, piping condition, power supply, and cooling capacity first. A replacement project needs full system matching, not only compressor HP matching.

We support common export power supply options such as 220V, 380V, 415V, and 460V, with 1Ph or 3Ph, 50Hz or 60Hz, depend on the model and project requirement. If your market uses a special power standard, please tell us before order confirmation.

Yes. We can offer units for hot climate projects and high ambient (>+45°C) outdoor installation. Please send your local ambient temperature, room temperature, and installation location before quotation.

Yes. We can support OEM branding, nameplate, packaging, voltage, refrigerant, structure type, and other project-based configurations. This option fits distributors, contractors, and customers with repeat orders or non-standard project requirements.

Please send your room size, target room temperature, product type, ambient temperature, power supply, refrigerant requirement, and installation location. If you already have drawings, BOQ, or evaporator information, please include them in your inquiry. Clear project information helps us recommend the right model and prepare a faster quotation.

Request A Free Quote

Ready to Start Your Project Wth Us?

Send us your project details, and our team will recommend a suitable model and quotation.

Related Refrigeration Products

Cold Room Condensing Unit

Box Type Condensing Unit

Walk-in Freezer

Hermetic Condensing Unit

Semi Hemetic Condensing Unit

Monoblock Refrigeration Unit

Don’t Miss Out the Best Partner!

Ready to Work With Us?

We customize the superior refrigeration products based on your idea or suggestion since 2010

Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.