Logo żużla

China HBP MBP Condensing Unit Manufacturer

Medium and high evaporating temperature condensing units for walk-in coolers, pomieszczenia chłodnicze, refrigerated display cabinets, and beverage coolers.

Speedway Refrigeration manufactures HBP MBP condensing units in China, with refrigerant options including R404/507/448/449/290, depending on the model. Share your application, required cooling capacity, design evaporating temperature, temperatura otoczenia, and power supply with our engineers to get a suitable unit selection and quotation.

Nasz partner

Silnik wentylatora Panasonica
Kompresor Maneurop
Logo Embraco
Kompresor Blaita
Wysoko
Kompresor tecumseh
Copelanda
Danfoss
sprężarka refcomp
SANYO
logo bitzera

What is the Difference Between HBP and MBP?

HBP stands for High Back Pressure i pokrywa wyższe temperatury parowania, such as beverage coolers and refrigerated display cabinets. MBP oznacza Średnie ciśnienie wsteczne and covers medium evaporating temperatures, such as walk-in coolers and chiller rooms. Dokładny zakres pracy zależy od modelu urządzenia, chłodziwo, i układ chłodniczy.

WybórHBP — High Back PressureMBP — średnie przeciwciśnienie
Temperatura parowania−5°C to +15°C (23°F to 59°F)−20°C to 0°C (−4°F to 32°F)
ZastosowaniaBeverage coolers, refrigerated display cabinets, and liquid coolingWalk-in coolers, pomieszczenia chłodnicze, and chilled goods storage
Capacity change from 25°C to 38°C ambientO 16.3% lower at +5°C evaporating temperatureO 17.1% lower at −10°C evaporating temperature
Lista kontrolna przy wyborze jednostkiCooling capacity at the design point and compressor operating limits at higher suction pressuresWydajność chłodnicza w punkcie projektowym chłodnicy i dobór parownika

Ogłoszenie: The typical ranges overlap from −5°C to 0°C (23°F to 32°F). Aby przeczytać tabelę wydajności, użyj projektowanej temperatury parowania projektu. Then check the specific condensing unit’s operating range and cooling capacity at your design ambient temperature and refrigerant.

HBP and MBP Models and Specifications

hermetyczny agregat skraplający-z logo

For Chiller room and Walk-in chiller HBP Application

  • Zakres modeli: Hermetyczny agregat skraplający

  • Seria kompresorów: Falownik obrotowy / sprężarka spiralna

  • Zakres mocy: 4KM ~ 10KM

  • Temperatura parowania: -5°C ~ +15°C

  • Aplikacja: HBP

  • Zakres temperatury pokojowej: 0°C ~ +10°C

  • Temperatura otoczenia: Do +42°C

  • Napięcie: 220V / 380V

  • Zasilacz: 1Doktorat / 3Doktorat, 50Hz / 60Hz

  • Czynniki chłodnicze: 290 zł / R404 / R448 / R449

  • Typ skraplacza: Chłodzony powietrzem skraplacz z wężownicą miedzianą

  • Opcja sterowania: Cyfrowy kontroler LED

  • Dopasowanie rozmrażania: Odszranianie elektryczne lub odszranianie gorącym gazem

hermetyczny agregat skraplający-z logo 1

For Refrigerated Cabnet and Chiller Room MBP Application

  • Zakres modeli: Inwerterowy agregat skraplający

  • Seria kompresorów: Falownik obrotowy / sprężarka spiralna

  • Zakres mocy: 2HP ~ 5HP

  • Temperatura parowania: +5°C ~ -15°C

  • Aplikacja: MBP

  • Zakres temperatury pokojowej: 0° C ~ -10 ° C.

  • Temperatura otoczenia: Do +43°C

  • Napięcie: 220V

  • Zasilacz: 1Doktorat / 3Doktorat, 50Hz / 60Hz

  • Czynniki chłodnicze: 290 zł / R404 / R448 / R449

  • Typ skraplacza: Chłodzony powietrzem skraplacz z wężownicą miedzianą

  • Opcja sterowania: Cyfrowy kontroler LED

  • Dopasowanie rozmrażania: Odszranianie elektryczne lub odszranianie gorącym gazem

hermetyczny agregat skraplający-z logo 3

For Walk-in Cooler, Beverage cooler and Chiller Room HBP MBP Application

  • Zakres modeli: Agregat skraplający typu skrzynkowego

  • Seria kompresorów: Obrotowe bez inwertera / sprężarka spiralna

  • Zakres mocy: 8KM ~ 45KM

  • Temperatura parowania: +10°C ~ -20°C

  • Aplikacja: HBP, MBP

  • Zakres temperatury pokojowej: +5°C ~ -18°C

  • Temperatura otoczenia: Do +45°C

  • Napięcie: 220V / 380V

  • Zasilacz: 1Doktorat / 3Doktorat, 50Hz / 60Hz

  • Czynniki chłodnicze: 290 zł / R404 / R448 / R449

  • Typ skraplacza: Chłodzony powietrzem skraplacz z wężownicą miedzianą

  • Opcja sterowania: Cyfrowy kontroler LED

  • Dopasowanie rozmrażania: Odszranianie elektryczne lub odszranianie gorącym gazem

Typ H Agregat skraplający

For Walk-in cooler and Chiller Room HBP MBP Application

  • Zakres modeli: Agregat skraplający typu H

  • Seria kompresorów: Obrotowe bez inwertera / sprężarka spiralna

  • Zakres mocy: 3KM ~ 20KM

  • Temperatura parowania: +5°C ~ -20°C

  • Aplikacja: HBP, MBP

  • Zakres temperatury pokojowej: +0°C ~ -15°C

  • Temperatura otoczenia: Do +43°C

  • Napięcie: 220V / 380V

  • Zasilacz: 1Doktorat / 3Doktorat, 50Hz / 60Hz

  • Czynniki chłodnicze: 290 zł / R404 / R448 / R449

  • Typ skraplacza: Chłodzony powietrzem skraplacz z wężownicą miedzianą

  • Opcja sterowania: Cyfrowy kontroler LED

  • Dopasowanie rozmrażania: Odszranianie elektryczne lub odszranianie gorącym gazem

półhermetyczny agregat skraplający 03

For Chiller room and Walk-in chiller HBP Application

  • Zakres modeli: Półhermetyczny agregat skraplający

  • Seria kompresorów: Sprężarka spiralna bez inwertera

  • Zakres mocy: 2KM ~ 40KM

  • Temperatura parowania: +15°C ~ -5°C

  • Aplikacja: HBP

  • Zakres temperatury pokojowej: 0°C ~ +15°C

  • Temperatura otoczenia: Do +45°C

  • Napięcie: 220V / 380V

  • Zasilacz: 1Doktorat / 3Doktorat, 50Hz / 60Hz

  • Czynniki chłodnicze: 290 zł / R404 / R448 / R449

  • Typ skraplacza: Chłodzony powietrzem skraplacz z wężownicą miedzianą

  • Opcja sterowania: Cyfrowy kontroler LED

  • Dopasowanie rozmrażania: Odszranianie elektryczne lub odszranianie gorącym gazem

Typ V Agregat skraplający

For Refrigerated cooler room and Walk-in chiller HBP MBP Application

  • Zakres modeli: Agregat skraplający typu V

  • Seria kompresorów: Sprężarka spiralna bez inwertera

  • Zakres mocy: 5KM ~ 45KM

  • Temperatura parowania: +10°C ~ -20°C

  • Aplikacja: HBP, MBP

  • Zakres temperatury pokojowej: +10°C ~ -18°C

  • Temperatura otoczenia: Do +45°C

  • Napięcie: 380V

  • Zasilacz: 3Doktorat, 50Hz / 60Hz

  • Czynniki chłodnicze: 290 zł / R404 / R448 / R449

  • Typ skraplacza: Chłodzony powietrzem skraplacz z wężownicą miedzianą

  • Opcja sterowania: Cyfrowy kontroler LED

  • Dopasowanie rozmrażania: Odszranianie elektryczne lub odszranianie gorącym gazem

HBP & MBP Condensing Unit Applications

Speedway supplies HBP and MBP condensing units for walk-in coolers, pomieszczenia chłodnicze, refrigerated display cabinets, chłodziarki do napojów, and chilled storage warehouses.

Walk-In Coolers and Chiller Rooms | MBP

MBP units suit fresh produce, mleczarnia, and chilled food storage in supermarkets and foodservice facilities. Size the unit for the cooling load from incoming products, frequent door openings, and daily operating conditions.

Refrigerated Display Cabinets and Beverage Coolers | HBP or MBP

HBP and MBP units serve beverage coolers and chilled display cabinets, depending on the design evaporating temperature. Check cooling capacity, compressor operating limits, and condenser ventilation for the cabinet’s installation conditions.

Chilled Warehouses and Distribution Centers | MBP

MBP units support chilled goods storage and distribution. Calculate each zone’s cooling load, account for product deliveries and loading activity, and check simultaneous demand when multiple evaporators share a refrigeration system.

Supermarket 2
Owoce w skrzynkach przechowywane w komercyjnej chłodni
zasięgowa zamrażarka 2

Dlaczego warto wybrać nasz agregat skraplający?

Szybciej wybieraj modele według zakresu temperatur, typ projektu, i zastosowanie.

Wybierz standardowe modele w przypadku regularnych zamówień lub opcje OEM w przypadku niestandardowych projektów.

Płynniej reguluj moc chłodzenia w zależności od zmieniającego się obciążenia pomieszczenia.

Popraw wydajność operacyjną, gdy komora chłodnicza nie pracuje przy pełnym obciążeniu.

Dopasuj napięcie lokalne, faza, i częstotliwość dla różnych rynków eksportowych.

Realizuj projekty w gorącym klimacie za pomocą odpowiednich systemów o wysokiej temperaturze otoczenia.

Stosuj energooszczędną sprężarkę Copeland/Sanyo/Highly, aby zaoszczędzić rachunki na zawsze

Rozumiemy Twój rynek i dopasowujemy urządzenia chłodnicze do lokalnych warunków pracy i wymagań klientów.

Components with optimal Performance

Cold room condenser

High-efficiency Cold Room Condenser

Speedway cold room condenser copper coil combines durable copper tubing with precision-formed aluminum fins. Uniform fin spacing promotes even airflow, while tight contact between the tubes and fins ensures efficient heat transfer (30% higher than other suppleirs) and reliable heat rejection.

Embraco/Bitzer/Copeland/Dorin Compressor

We offer world famous compressor options for HBP and MBP condensing units, and match each compressor to the required cooling capacity, chłodziwo, temperatura parowania, and ambient conditions to support reliable operation.

Kompresor Copeland Emerson

Solid Condensing Unit Casing

Speedway rigid casing protects key components during handling and installation. Secure mounting points hold the compressor and condenser copper coil in position, while removable panels give technicians direct access for inspection and routine maintenance.

Cold Room Evaporators in Multiple Sizes

Speedway offer evaporators with fan diameters from 300 Do 800 mm and fin spacing from 4 Do 16 mm. We match copper coil capacity and airflow to the cooling load and operating temperature of each walk-in cooler or chiller room.

parownik chłodniczy
Unikalna konstrukcja płyty falownika 5HP

Smart Inverter Board with Self-Diagnostics

Speedway inverter board adjusts compressor speed to match cooling demand and monitors operating conditions in real time. Its self-diagnostics flag faults, helping technicians troubleshoot during commissioning and reduce downtime during service.

Accurate Temp Control

Our thermostat monitors cold room temperature and regulates cooling around the selected setpoint. This precise control limits temperature fluctuations and helps maintain stable conditions for both chilled and frozen products.

Thermostat for cold room

Production Workshop and Pre-Shipment Inspection

Żużel technicians assemble the refrigerant circuit and electrical controls, then inspect brazed joints, wiring connections, and component mounts. Przed wysyłką, we conduct pressure hold tests and leak checks to verify refrigerant circuit integrity. We run the units to confirm compressor, wentylator, and control operation, then secure them for handling and transport.

condensing unit inverter board

Keep Pressure and Anti-leak

Packed Condensing unit-ready to ship

Packed Condensing Unit-Ready to Ship

CDU Running Test before shippment

Condensing Unit Parameter Test at Pre-shipment

Key Technology and Performance Benefits

1.Enhanced Vapor Injection

Enhanced Vapor Injection(EVI) use plate heat exchanger subcools the liquid refrigerant in the main circuit while vaporizing refrigerant in a separate branch. The resulting intermediate-pressure vapor enters the compressor through a dedicated injection port.

In cold rooms, EVI increases cooling capacity at low evaporating temperatures, making it particularly suitable for walk-in freezers. It can also improve energy efficiency when the unit matches the operating conditions.

2.Variable-Speed Compressor

Speedway inverter condensing units automatically adjust compressor speed to match the cold room’s cooling load. After large deliveries or frequent door openings, they can increase cooling output to help the room return to its setpoint faster. At lower loads, they can run at reduced speed to reduce on/off cycling, limit temperature fluctuations, and cut part-load energy use.

3.High-Ambient Performance

We match the condenser and fans to maintain effective heat rejection in hot weather. Select models operate at outdoor ambient temperatures up to 50 °C. We size each unit for the project’s peak outdoor temperature to help maintain the target cold room temperature during the hottest periods.

4.Odszranianie gorącym gazem

Odszranianie gorącym gazem is a method that directs hot refrigerant vapor from the compressor discharge through the evaporator coil to melt frost on the coil surface. Speedway condensing units use hot refrigerant vapor from the compressor to warm the evaporator coil from within and melt frost, reducing reliance on electric coil heaters. When we match the condensing unit to the evaporator, hot gas defrost can shorten cooling interruptions, restore airflow and cooling sooner, and limit the rise in cold room temperature during defrost.

Często zadawane pytania

HBP stands for High Back Pressure i pokrywa wyższe temperatury parowania. MBP oznacza Średnie ciśnienie wsteczne and serves medium-temperature refrigeration. Select a unit by its operating range, chłodziwo, and cooling capacity at your design conditions.

HBP units serve applications such as beverage cooling, refrigerated display cabinets, and liquid cooling. MBP units commonly serve walk-in coolers, pomieszczenia chłodnicze, and chilled warehouses. Some applications overlap, so confirm the required evaporating temperature before selecting a model.

NIE. Room temperature provides a starting point. Also confirm the design evaporating temperature, obciążenie chłodnicze, and peak ambient temperature. The evaporator’s temperature difference and the product’s humidity requirements also influence unit selection.

Tak, when the compressor’s operating range covers both duty points. Check cooling capacity and power consumption at each point using the project’s refrigerant, temperatura parowania, and ambient temperature.

Start with the calculated cooling load in kW. Share the target temperature, insulation thickness, obciążenie produktu, door-opening frequency, i warunki otoczenia. Our engineers use these details to select a unit that meets the project’s cooling demand.

Refrigerant options depend on the compressor and unit model, can choose from R404/507/448/449/290 and more.

YES.A suitable system can serve multiple evaporators when its capacity, rurociąg, and controls match the application. Share each evaporator’s cooling load, operating temperature, and usage schedule so our engineers can review simultaneous demand and capacity control.

We offer standard and OEM refrigeration system. Share your destination market, Napięcie, faza, częstotliwość, and any limits on cold room size or connection location. W przypadku powtarzających się zamówień, ask us to confirm the model code and component list so you can re-order the same system.

Q9.Yes. Send the evaporator model, performance sheet, chłodziwo, and expansion valve details. We check capacity at the same design evaporating temperature and review airflow, refrigerant control, and defrost requirements for your application.

Consider how much the cooling load changes during operation. Inverter units adjust compressor speed as demand changes. Non-inverter units use on/off control. Compare capacity, part-load operation, sterownica, and service requirements for your project.

Poproś o bezpłatną wycenę

Gotowy do rozpoczęcia projektu z nami?

Współpracuj z nami, aby zwiększyć reputację swojej marki, uzyskaj imponujące wrażenia, aby Twoi klienci zapamiętali Cię na całe życie, i pomóc wyróżnić się na konkurencyjnym rynku !

Powiązane produkty chłodnicze

Hermetyczny agregat skraplający

Inwerterowy agregat skraplający

Agregat skraplający typu skrzynkowego

Półhemetyczny agregat skraplający

Jednostka monoblokowa inwertera

Agregat skraplający do chłodni

Prawidłowe obliczenia mogą zmniejszyć budżet chłodni

Kalkulator chłodzenia chłodni

Kalkulator przechowywania w chłodni

Oszacuj wydajność chłodzenia & grubość panelu na podstawie wymiarów pomieszczenia
Wymiary pokoju
M
M
M
Temperatura przechowywania
Scenariusz użycia
Całkowita objętość
0 M³
Wydajność chłodnicza
0 kW
Moc sprężarki
0 HP
Grubość panelu
0 mm

Zalecenia

  • ✓Płyta: ...
  • ✓Kompresor: ...
  • ✓Parownik: ...
  • ✓Skraplacz: ...

Notatka: Tylko wstępne odniesienie. Aby uzyskać ostateczny projekt, skonsultuj się ze specjalistą.

Nie przegap najlepszego partnera!

Gotowy do pracy z nami?

Od tego czasu dostosowujemy najwyższej jakości produkty chłodnicze w oparciu o Twój pomysł lub sugestię 2010