Medium and high evaporating temperature condensing units for walk-in coolers, ห้องเย็น, refrigerated display cabinets, and beverage coolers.
Speedway Refrigeration manufactures HBP MBP condensing units in China, with refrigerant options including R404/507/448/449/290, depending on the model. Share your application, required cooling capacity, design evaporating temperature, อุณหภูมิโดยรอบ, and power supply with our engineers to get a suitable unit selection and quotation.
HBP stands for High Back Pressure and covers higher evaporating temperatures, such as beverage coolers and refrigerated display cabinets. MBP stands for Medium Back Pressure and covers medium evaporating temperatures, such as walk-in coolers and chiller rooms. The exact operating range depends on the unit model, สารทำความเย็น, และระบบทำความเย็น.
| Selection | HBP — High Back Pressure | MBP — Medium Back Pressure |
|---|---|---|
| อุณหภูมิระเหย | −5°C to +15°C (23°F to 59°F) | −20°C to 0°C (−4°F to 32°F) |
| แอปพลิเคชัน | Beverage coolers, refrigerated display cabinets, and liquid cooling | Walk-in coolers, ห้องเย็น, and chilled goods storage |
| Capacity change from 25°C to 38°C ambient | เกี่ยวกับ 16.3% lower at +5°C evaporating temperature | เกี่ยวกับ 17.1% lower at −10°C evaporating temperature |
| Checklist when selecting a unit | Cooling capacity at the design point and compressor operating limits at higher suction pressures | Cooling capacity at the cooler design point and evaporator sizing |
สังเกต: The typical ranges overlap from −5°C to 0°C (23°F to 32°F). Use the project’s design evaporating temperature to read the performance table. Then check the specific condensing unit’s operating range and cooling capacity at your design ambient temperature and refrigerant.
For Chiller room and Walk-in chiller HBP Application
ช่วงโมเดล: Hermetic condensing unit
ซีรี่ส์คอมเพรสเซอร์: อินเวอร์เตอร์แบบหมุน / คอมเพรสเซอร์แบบเลื่อน
ช่วงแรงม้า: 4HP ~ 10HP
อุณหภูมิการระเหย: -5°C ~ +15°C
แอปพลิเคชัน: เอชบีพี
ช่วงอุณหภูมิห้อง: 0°C ~ +10°C
อุณหภูมิโดยรอบ: Up to +42°C
แรงดันไฟฟ้า: 220วี / 380วี
พาวเวอร์ซัพพลาย: 1ปริญญาเอก / 3ปริญญาเอก, 50เฮิรตซ์ / 60เฮิรตซ์
สารทำความเย็น: R290 / R404 / อาร์448 / R449
ประเภทคอนเดนเซอร์: Air cooled finned copper coil condenser
ตัวเลือกการควบคุม: คอนโทรลเลอร์ดิจิตอล LED
การจับคู่การละลายน้ำแข็ง: การละลายน้ำแข็งด้วยไฟฟ้าหรือการละลายน้ำแข็งด้วยแก๊สร้อน
For Refrigerated Cabnet and Chiller Room MBP Application
ช่วงโมเดล: หน่วยกลั่นตัวอินเวอร์เตอร์
ซีรี่ส์คอมเพรสเซอร์: อินเวอร์เตอร์แบบหมุน / คอมเพรสเซอร์แบบเลื่อน
ช่วงแรงม้า: 2HP ~ 5HP
อุณหภูมิการระเหย: +5องศาเซลเซียส ~ -15 องศาเซลเซียส
แอปพลิเคชัน: เอ็มบีพี
ช่วงอุณหภูมิห้อง: 0° C ~ -10 ° C
อุณหภูมิโดยรอบ: สูงถึง +43°C
แรงดันไฟฟ้า: 220วี
พาวเวอร์ซัพพลาย: 1ปริญญาเอก / 3ปริญญาเอก, 50เฮิรตซ์ / 60เฮิรตซ์
สารทำความเย็น: R290 / R404 / อาร์448 / R449
ประเภทคอนเดนเซอร์: Air cooled finned copper coil condenser
ตัวเลือกการควบคุม: คอนโทรลเลอร์ดิจิตอล LED
การจับคู่การละลายน้ำแข็ง: การละลายน้ำแข็งด้วยไฟฟ้าหรือการละลายน้ำแข็งด้วยแก๊สร้อน
For Walk-in Cooler, Beverage cooler and Chiller Room HBP MBP Application
ช่วงโมเดล: Box type condensing unit
ซีรี่ส์คอมเพรสเซอร์: Non-inverter rotary / คอมเพรสเซอร์แบบเลื่อน
ช่วงแรงม้า: 8HP ~ 45HP
อุณหภูมิการระเหย: +10°C ~ -20°C
แอปพลิเคชัน: เอชบีพี, เอ็มบีพี
ช่วงอุณหภูมิห้อง: +5องศาเซลเซียส ~ -18 องศาเซลเซียส
อุณหภูมิโดยรอบ: สูงถึง +45°C
แรงดันไฟฟ้า: 220วี / 380วี
พาวเวอร์ซัพพลาย: 1ปริญญาเอก / 3ปริญญาเอก, 50เฮิรตซ์ / 60เฮิรตซ์
สารทำความเย็น: R290 / R404 / อาร์448 / R449
ประเภทคอนเดนเซอร์: Air cooled finned copper coil condenser
ตัวเลือกการควบคุม: คอนโทรลเลอร์ดิจิตอล LED
การจับคู่การละลายน้ำแข็ง: การละลายน้ำแข็งด้วยไฟฟ้าหรือการละลายน้ำแข็งด้วยแก๊สร้อน
For Walk-in cooler and Chiller Room HBP MBP Application
ช่วงโมเดล: H type condensing unit
ซีรี่ส์คอมเพรสเซอร์: Non-inverter rotary / คอมเพรสเซอร์แบบเลื่อน
ช่วงแรงม้า: 3HP ~ 20HP
อุณหภูมิการระเหย: +5°C ~ -20°C
แอปพลิเคชัน: เอชบีพี, เอ็มบีพี
ช่วงอุณหภูมิห้อง: +0องศาเซลเซียส ~ -15 องศาเซลเซียส
อุณหภูมิโดยรอบ: สูงถึง +43°C
แรงดันไฟฟ้า: 220วี / 380วี
พาวเวอร์ซัพพลาย: 1ปริญญาเอก / 3ปริญญาเอก, 50เฮิรตซ์ / 60เฮิรตซ์
สารทำความเย็น: R290 / R404 / อาร์448 / R449
ประเภทคอนเดนเซอร์: Air cooled finned copper coil condenser
ตัวเลือกการควบคุม: คอนโทรลเลอร์ดิจิตอล LED
การจับคู่การละลายน้ำแข็ง: การละลายน้ำแข็งด้วยไฟฟ้าหรือการละลายน้ำแข็งด้วยแก๊สร้อน
For Chiller room and Walk-in chiller HBP Application
ช่วงโมเดล: หน่วยควบแน่นกึ่งสุญญากาศ
ซีรี่ส์คอมเพรสเซอร์: Non-inverter scroll compressor
ช่วงแรงม้า: 2HP ~ 40HP
อุณหภูมิการระเหย: +15°ซ ~ -5°ซ
แอปพลิเคชัน: เอชบีพี
ช่วงอุณหภูมิห้อง: 0°C ~ +15°C
อุณหภูมิโดยรอบ: สูงถึง +45°C
แรงดันไฟฟ้า: 220วี / 380วี
พาวเวอร์ซัพพลาย: 1ปริญญาเอก / 3ปริญญาเอก, 50เฮิรตซ์ / 60เฮิรตซ์
สารทำความเย็น: R290 / R404 / อาร์448 / R449
ประเภทคอนเดนเซอร์: Air cooled finned copper coil condenser
ตัวเลือกการควบคุม: คอนโทรลเลอร์ดิจิตอล LED
การจับคู่การละลายน้ำแข็ง: การละลายน้ำแข็งด้วยไฟฟ้าหรือการละลายน้ำแข็งด้วยแก๊สร้อน
For Refrigerated cooler room and Walk-in chiller HBP MBP Application
ช่วงโมเดล: V Type condensing unit
ซีรี่ส์คอมเพรสเซอร์: Non-inverter scroll compressor
ช่วงแรงม้า: 5HP ~ 45HP
อุณหภูมิการระเหย: +10°C ~ -20°C
แอปพลิเคชัน: เอชบีพี, เอ็มบีพี
ช่วงอุณหภูมิห้อง: +10องศาเซลเซียส ~ -18 องศาเซลเซียส
อุณหภูมิโดยรอบ: สูงถึง +45°C
แรงดันไฟฟ้า: 380วี
พาวเวอร์ซัพพลาย: 3ปริญญาเอก, 50เฮิรตซ์ / 60เฮิรตซ์
สารทำความเย็น: R290 / R404 / อาร์448 / R449
ประเภทคอนเดนเซอร์: Air cooled finned copper coil condenser
ตัวเลือกการควบคุม: คอนโทรลเลอร์ดิจิตอล LED
การจับคู่การละลายน้ำแข็ง: การละลายน้ำแข็งด้วยไฟฟ้าหรือการละลายน้ำแข็งด้วยแก๊สร้อน
Speedway supplies HBP and MBP condensing units for walk-in coolers, ห้องเย็น, refrigerated display cabinets, ตู้แช่เครื่องดื่ม, and chilled storage warehouses.
Walk-In Coolers and Chiller Rooms | เอ็มบีพี
MBP units suit fresh produce, ผลิตภัณฑ์นม, and chilled food storage in supermarkets and foodservice facilities. Size the unit for the cooling load from incoming products, frequent door openings, and daily operating conditions.
Refrigerated Display Cabinets and Beverage Coolers | HBP or MBP
HBP and MBP units serve beverage coolers and chilled display cabinets, depending on the design evaporating temperature. Check cooling capacity, compressor operating limits, and condenser ventilation for the cabinet’s installation conditions.
Chilled Warehouses and Distribution Centers | เอ็มบีพี
MBP units support chilled goods storage and distribution. Calculate each zone’s cooling load, account for product deliveries and loading activity, and check simultaneous demand when multiple evaporators share a refrigeration system.
เลือกรุ่นได้เร็วขึ้นตามช่วงอุณหภูมิ, ประเภทโครงการ, และการประยุกต์ใช้.
เลือกรุ่นมาตรฐานสำหรับการสั่งซื้อปกติหรือตัวเลือก OEM สำหรับโครงการที่กำหนดเอง.
ปรับเอาต์พุตการทำความเย็นได้ราบรื่นยิ่งขึ้นภายใต้ภาระห้องเปลี่ยน.
ปรับปรุงประสิทธิภาพการทำงานเมื่อห้องเย็นไม่ทำงานเต็มที่.
จับคู่แรงดันไฟฟ้าท้องถิ่น, เฟส, และความถี่ของตลาดส่งออกต่างๆ.
จัดการโครงการที่มีอากาศร้อนด้วยระบบสภาพแวดล้อมสูงที่เหมาะสม.
Use energy-saving Copeland/Sanyo/Highly compressor, to save you bill forever
We understand your market and match refrigeration equipment to local operating conditions and customer requirements.
High-efficiency Cold Room Condenser
Speedway cold room condenser copper coil combines durable copper tubing with precision-formed aluminum fins. Uniform fin spacing promotes even airflow, while tight contact between the tubes and fins ensures efficient heat transfer (30% higher than other suppleirs) and reliable heat rejection.
Embraco/Bitzer/Copeland/Dorin Compressor
We offer world famous compressor options for HBP and MBP condensing units, and match each compressor to the required cooling capacity, สารทำความเย็น, อุณหภูมิการระเหย, and ambient conditions to support reliable operation.
Solid Condensing Unit Casing
Speedway rigid casing protects key components during handling and installation. Secure mounting points hold the compressor and condenser copper coil in position, while removable panels give technicians direct access for inspection and routine maintenance.
Cold Room Evaporators in Multiple Sizes
Speedway offer evaporators with fan diameters from 300 ถึง 800 mm and fin spacing from 4 ถึง 16 มม. We match copper coil capacity and airflow to the cooling load and operating temperature of each walk-in cooler or chiller room.
Smart Inverter Board with Self-Diagnostics
Speedway inverter board adjusts compressor speed to match cooling demand and monitors operating conditions in real time. Its self-diagnostics flag faults, helping technicians troubleshoot during commissioning and reduce downtime during service.
Accurate Temp Control
Our thermostat monitors cold room temperature and regulates cooling around the selected setpoint. This precise control limits temperature fluctuations and helps maintain stable conditions for both chilled and frozen products.
สปีดเวย์ technicians assemble the refrigerant circuit and electrical controls, then inspect brazed joints, wiring connections, and component mounts. ก่อนจัดส่ง, we conduct pressure hold tests and leak checks to verify refrigerant circuit integrity. We run the units to confirm compressor, พัดลม, and control operation, then secure them for handling and transport.
Keep Pressure and Anti-leak
Packed Condensing Unit-Ready to Ship
Condensing Unit Parameter Test at Pre-shipment
1.Enhanced Vapor Injection
Enhanced Vapor Injection(EVI) use plate heat exchanger subcools the liquid refrigerant in the main circuit while vaporizing refrigerant in a separate branch. The resulting intermediate-pressure vapor enters the compressor through a dedicated injection port.
In cold rooms, EVI increases cooling capacity at low evaporating temperatures, making it particularly suitable for walk-in freezers. It can also improve energy efficiency when the unit matches the operating conditions.
2.Variable-Speed Compressor
Speedway inverter condensing units automatically adjust compressor speed to match the cold room’s cooling load. After large deliveries or frequent door openings, they can increase cooling output to help the room return to its setpoint faster. At lower loads, they can run at reduced speed to reduce on/off cycling, limit temperature fluctuations, and cut part-load energy use.
3.High-Ambient Performance
We match the condenser and fans to maintain effective heat rejection in hot weather. Select models operate at outdoor ambient temperatures up to 50 องศาเซลเซียส. We size each unit for the project’s peak outdoor temperature to help maintain the target cold room temperature during the hottest periods.
4.ละลายน้ำแข็งด้วยแก๊สร้อน
ละลายน้ำแข็งด้วยแก๊สร้อน is a method that directs hot refrigerant vapor from the compressor discharge through the evaporator coil to melt frost on the coil surface. Speedway condensing units use hot refrigerant vapor from the compressor to warm the evaporator coil from within and melt frost, reducing reliance on electric coil heaters. When we match the condensing unit to the evaporator, hot gas defrost can shorten cooling interruptions, restore airflow and cooling sooner, and limit the rise in cold room temperature during defrost.
HBP stands for High Back Pressure and covers higher evaporating temperatures. MBP stands for Medium Back Pressure and serves medium-temperature refrigeration. Select a unit by its operating range, สารทำความเย็น, and cooling capacity at your design conditions.
HBP units serve applications such as beverage cooling, refrigerated display cabinets, and liquid cooling. MBP units commonly serve walk-in coolers, ห้องเย็น, and chilled warehouses. Some applications overlap, so confirm the required evaporating temperature before selecting a model.
เลขที่. Room temperature provides a starting point. Also confirm the design evaporating temperature, โหลดการทำความเย็น, and peak ambient temperature. The evaporator’s temperature difference and the product’s humidity requirements also influence unit selection.
ใช่, when the compressor’s operating range covers both duty points. Check cooling capacity and power consumption at each point using the project’s refrigerant, อุณหภูมิการระเหย, and ambient temperature.
Start with the calculated cooling load in kW. Share the target temperature, insulation thickness, โหลดผลิตภัณฑ์, door-opening frequency, และสภาพแวดล้อม. Our engineers use these details to select a unit that meets the project’s cooling demand.
Refrigerant options depend on the compressor and unit model, can choose from R404/507/448/449/290 and more.
YES.A suitable system can serve multiple evaporators when its capacity, ท่อ, and controls match the application. Share each evaporator’s cooling load, operating temperature, and usage schedule so our engineers can review simultaneous demand and capacity control.
We offer standard and OEM refrigeration system. Share your destination market, แรงดันไฟฟ้า, เฟส, ความถี่, and any limits on cold room size or connection location. สำหรับการสั่งซื้อซ้ำ, ask us to confirm the model code and component list so you can re-order the same system.
Q9.Yes. Send the evaporator model, performance sheet, สารทำความเย็น, and expansion valve details. We check capacity at the same design evaporating temperature and review airflow, refrigerant control, and defrost requirements for your application.
Consider how much the cooling load changes during operation. Inverter units adjust compressor speed as demand changes. Non-inverter units use on/off control. Compare capacity, part-load operation, การควบคุม, and service requirements for your project.
ร่วมเป็นพันธมิตรกับเราเพื่อเพิ่มชื่อเสียงให้กับแบรนด์ของคุณ, รับประสบการณ์ที่น่าประทับใจเพื่อให้ลูกค้าจดจำคุณไปตลอดชีวิต, และช่วยให้คุณโดดเด่นในตลาดที่มีการแข่งขันสูง !
การคำนวณที่ถูกต้องสามารถลดงบประมาณห้องเย็นของคุณได้
บันทึก: การอ้างอิงเบื้องต้นเท่านั้น. ปรึกษาผู้เชี่ยวชาญในการออกแบบขั้นสุดท้าย.
เราปรับแต่งผลิตภัณฑ์ทำความเย็นที่เหนือกว่าตามแนวคิดหรือข้อเสนอแนะของคุณตั้งแต่นั้นเป็นต้นมา 2010