Logotipo do autódromo

China HBP MBP Condensing Unit Manufacturer

Medium and high evaporating temperature condensing units for walk-in coolers, salas de resfriamento, refrigerated display cabinets, and beverage coolers.

Speedway Refrigeration manufactures HBP MBP condensing units in China, with refrigerant options including R404/507/448/449/290, depending on the model. Share your application, required cooling capacity, design evaporating temperature, temperatura ambiente, and power supply with our engineers to get a suitable unit selection and quotation.

Nosso parceiro

motor ventilador Panasonic
Compressor Maneurop
Logotipo da Embraco
Compressor Blait
Altamente
compressor tecumseh
Copeland
danfoss
compressor refcomp
SANYO
logotipo bitzer

What is the Difference Between HBP and MBP?

HBP stands for High Back Pressure and covers higher evaporating temperatures, such as beverage coolers and refrigerated display cabinets. MBP stands for Medium Back Pressure and covers medium evaporating temperatures, such as walk-in coolers and chiller rooms. The exact operating range depends on the unit model, refrigerante, e sistema de refrigeração.

SelectionHBP — High Back PressureMBP — Medium Back Pressure
Temperatura de evaporação−5°C to +15°C (23°F to 59°F)−20°C to 0°C (−4°F to 32°F)
AplicaçõesBeverage coolers, refrigerated display cabinets, and liquid coolingWalk-in coolers, salas de resfriamento, and chilled goods storage
Capacity change from 25°C to 38°C ambientSobre 16.3% lower at +5°C evaporating temperatureSobre 17.1% lower at −10°C evaporating temperature
Checklist when selecting a unitCooling capacity at the design point and compressor operating limits at higher suction pressuresCooling capacity at the cooler design point and evaporator sizing

Perceber: The typical ranges overlap from −5°C to 0°C (23°F to 32°F). Use the project’s design evaporating temperature to read the performance table. Then check the specific condensing unit’s operating range and cooling capacity at your design ambient temperature and refrigerant.

HBP and MBP Models and Specifications

unidade de condensação hermética - com logotipo

For Chiller room and Walk-in chiller HBP Application

  • Gama de modelos: Hermetic condensing unit

  • Série de compressores: Inversor rotativo / compressor de rolagem

  • Faixa de potência: 4HP ~ 10HP

  • Temperatura de evaporação: -5°C ~ +15°C

  • Aplicativo: HBP

  • Faixa de temperatura ambiente: 0°C ~ +10°C

  • Temperatura ambiente: Up to +42°C

  • Tensão: 220V / 380V

  • Fonte de energia: 1Ph. / 3Ph., 50Hz / 60Hz

  • Refrigerantes: R290 / R404 / R448 / R449

  • Tipo de condensador: Air cooled finned copper coil condenser

  • Opção de controle: Controlador digital LED

  • Correspondência de descongelamento: Descongelamento eléctrico ou descongelamento a gás quente

unidade de condensação hermética - com logotipo 1

For Refrigerated Cabnet and Chiller Room MBP Application

  • Gama de modelos: Unidade de condensação do inversor

  • Série de compressores: Inversor rotativo / compressor de rolagem

  • Faixa de potência: 2HP ~ 5HP

  • Temperatura de evaporação: +5°C ~ -15°C

  • Aplicativo: MBP

  • Faixa de temperatura ambiente: 0° C ~ -10 ° C.

  • Temperatura ambiente: Até +43°C

  • Tensão: 220V

  • Fonte de energia: 1Ph. / 3Ph., 50Hz / 60Hz

  • Refrigerantes: R290 / R404 / R448 / R449

  • Tipo de condensador: Air cooled finned copper coil condenser

  • Opção de controle: Controlador digital LED

  • Correspondência de descongelamento: Descongelamento eléctrico ou descongelamento a gás quente

unidade de condensação hermética - com logotipo 3

For Walk-in Cooler, Beverage cooler and Chiller Room HBP MBP Application

  • Gama de modelos: Box type condensing unit

  • Série de compressores: Non-inverter rotary / compressor de rolagem

  • Faixa de potência: 8HP ~ 45HP

  • Temperatura de evaporação: +10°C ~ -20°C

  • Aplicativo: HBP, MBP

  • Faixa de temperatura ambiente: +5°C ~ -18°C

  • Temperatura ambiente: Até +45°C

  • Tensão: 220V / 380V

  • Fonte de energia: 1Ph. / 3Ph., 50Hz / 60Hz

  • Refrigerantes: R290 / R404 / R448 / R449

  • Tipo de condensador: Air cooled finned copper coil condenser

  • Opção de controle: Controlador digital LED

  • Correspondência de descongelamento: Descongelamento eléctrico ou descongelamento a gás quente

Unidade de condensação tipo H

For Walk-in cooler and Chiller Room HBP MBP Application

  • Gama de modelos: H type condensing unit

  • Série de compressores: Non-inverter rotary / compressor de rolagem

  • Faixa de potência: 3HP ~ 20HP

  • Temperatura de evaporação: +5°C ~ -20°C

  • Aplicativo: HBP, MBP

  • Faixa de temperatura ambiente: +0°C ~ -15°C

  • Temperatura ambiente: Até +43°C

  • Tensão: 220V / 380V

  • Fonte de energia: 1Ph. / 3Ph., 50Hz / 60Hz

  • Refrigerantes: R290 / R404 / R448 / R449

  • Tipo de condensador: Air cooled finned copper coil condenser

  • Opção de controle: Controlador digital LED

  • Correspondência de descongelamento: Descongelamento eléctrico ou descongelamento a gás quente

unidade de condensação semi-hermética 03

For Chiller room and Walk-in chiller HBP Application

  • Gama de modelos: Unidade de condensação semi-hermética

  • Série de compressores: Non-inverter scroll compressor

  • Faixa de potência: 2HP ~ 40HP

  • Temperatura de evaporação: +15°C ~ -5°C

  • Aplicativo: HBP

  • Faixa de temperatura ambiente: 0°C ~ +15°C

  • Temperatura ambiente: Até +45°C

  • Tensão: 220V / 380V

  • Fonte de energia: 1Ph. / 3Ph., 50Hz / 60Hz

  • Refrigerantes: R290 / R404 / R448 / R449

  • Tipo de condensador: Air cooled finned copper coil condenser

  • Opção de controle: Controlador digital LED

  • Correspondência de descongelamento: Descongelamento eléctrico ou descongelamento a gás quente

Unidade de condensação tipo V

For Refrigerated cooler room and Walk-in chiller HBP MBP Application

  • Gama de modelos: V Type condensing unit

  • Série de compressores: Non-inverter scroll compressor

  • Faixa de potência: 5HP ~ 45HP

  • Temperatura de evaporação: +10°C ~ -20°C

  • Aplicativo: HBP, MBP

  • Faixa de temperatura ambiente: +10°C ~ -18°C

  • Temperatura ambiente: Até +45°C

  • Tensão: 380V

  • Fonte de energia: 3Ph., 50Hz / 60Hz

  • Refrigerantes: R290 / R404 / R448 / R449

  • Tipo de condensador: Air cooled finned copper coil condenser

  • Opção de controle: Controlador digital LED

  • Correspondência de descongelamento: Descongelamento eléctrico ou descongelamento a gás quente

HBP & MBP Condensing Unit Applications

Speedway supplies HBP and MBP condensing units for walk-in coolers, salas de resfriamento, refrigerated display cabinets, refrigeradores de bebidas, and chilled storage warehouses.

Walk-In Coolers and Chiller Rooms | MBP

MBP units suit fresh produce, laticínio, and chilled food storage in supermarkets and foodservice facilities. Size the unit for the cooling load from incoming products, frequent door openings, and daily operating conditions.

Refrigerated Display Cabinets and Beverage Coolers | HBP or MBP

HBP and MBP units serve beverage coolers and chilled display cabinets, depending on the design evaporating temperature. Check cooling capacity, compressor operating limits, and condenser ventilation for the cabinet’s installation conditions.

Chilled Warehouses and Distribution Centers | MBP

MBP units support chilled goods storage and distribution. Calculate each zone’s cooling load, account for product deliveries and loading activity, and check simultaneous demand when multiple evaporators share a refrigeration system.

Supermercado 2
Frutas embaladas armazenadas em câmara frigorífica comercial
freezer de alcance 2

Por que escolher nossa unidade de condensação?

Selecione modelos mais rapidamente por faixa de temperatura, tipo de projeto, e aplicação.

Escolha modelos padrão para pedidos regulares ou opções OEM para projetos personalizados.

Ajuste a saída de resfriamento de forma mais suave sob a carga do vestiário.

Melhore a eficiência operacional quando a câmara fria não funcionar com carga total.

Combine a tensão local, fase, e frequência para diferentes mercados de exportação.

Lidar com projetos de clima quente com sistemas ambientais elevados adequados.

Use energy-saving Copeland/Sanyo/Highly compressor, to save you bill forever

We understand your market and match refrigeration equipment to local operating conditions and customer requirements.

Components with optimal Performance

Cold room condenser

High-efficiency Cold Room Condenser

Speedway cold room condenser copper coil combines durable copper tubing with precision-formed aluminum fins. Uniform fin spacing promotes even airflow, while tight contact between the tubes and fins ensures efficient heat transfer (30% higher than other suppleirs) and reliable heat rejection.

Embraco/Bitzer/Copeland/Dorin Compressor

We offer world famous compressor options for HBP and MBP condensing units, and match each compressor to the required cooling capacity, refrigerante, temperatura de evaporação, and ambient conditions to support reliable operation.

Compressor Copeland Emerson

Solid Condensing Unit Casing

Speedway rigid casing protects key components during handling and installation. Secure mounting points hold the compressor and condenser copper coil in position, while removable panels give technicians direct access for inspection and routine maintenance.

Cold Room Evaporators in Multiple Sizes

Speedway offer evaporators with fan diameters from 300 para 800 mm and fin spacing from 4 para 16 milímetros. We match copper coil capacity and airflow to the cooling load and operating temperature of each walk-in cooler or chiller room.

evaporador de câmara fria
Placa inversora 5HP de design exclusivo

Smart Inverter Board with Self-Diagnostics

Speedway inverter board adjusts compressor speed to match cooling demand and monitors operating conditions in real time. Its self-diagnostics flag faults, helping technicians troubleshoot during commissioning and reduce downtime during service.

Accurate Temp Control

Our thermostat monitors cold room temperature and regulates cooling around the selected setpoint. This precise control limits temperature fluctuations and helps maintain stable conditions for both chilled and frozen products.

Thermostat for cold room

Production Workshop and Pre-Shipment Inspection

Autódromo technicians assemble the refrigerant circuit and electrical controls, then inspect brazed joints, wiring connections, and component mounts. Antes do envio, we conduct pressure hold tests and leak checks to verify refrigerant circuit integrity. We run the units to confirm compressor, fã, and control operation, then secure them for handling and transport.

condensing unit inverter board

Keep Pressure and Anti-leak

Packed Condensing unit-ready to ship

Packed Condensing Unit-Ready to Ship

CDU Running Test before shippment

Condensing Unit Parameter Test at Pre-shipment

Key Technology and Performance Benefits

1.Enhanced Vapor Injection

Enhanced Vapor Injection(EVI) use plate heat exchanger subcools the liquid refrigerant in the main circuit while vaporizing refrigerant in a separate branch. The resulting intermediate-pressure vapor enters the compressor through a dedicated injection port.

In cold rooms, EVI increases cooling capacity at low evaporating temperatures, making it particularly suitable for walk-in freezers. It can also improve energy efficiency when the unit matches the operating conditions.

2.Variable-Speed Compressor

Speedway inverter condensing units automatically adjust compressor speed to match the cold room’s cooling load. After large deliveries or frequent door openings, they can increase cooling output to help the room return to its setpoint faster. At lower loads, they can run at reduced speed to reduce on/off cycling, limit temperature fluctuations, and cut part-load energy use.

3.High-Ambient Performance

We match the condenser and fans to maintain effective heat rejection in hot weather. Select models operate at outdoor ambient temperatures up to 50 °C. We size each unit for the project’s peak outdoor temperature to help maintain the target cold room temperature during the hottest periods.

4.Descongelamento com gás quente

Descongelamento a gás quente is a method that directs hot refrigerant vapor from the compressor discharge through the evaporator coil to melt frost on the coil surface. Speedway condensing units use hot refrigerant vapor from the compressor to warm the evaporator coil from within and melt frost, reducing reliance on electric coil heaters. When we match the condensing unit to the evaporator, hot gas defrost can shorten cooling interruptions, restore airflow and cooling sooner, and limit the rise in cold room temperature during defrost.

As perguntas frequentes

HBP stands for High Back Pressure and covers higher evaporating temperatures. MBP stands for Medium Back Pressure and serves medium-temperature refrigeration. Select a unit by its operating range, refrigerante, and cooling capacity at your design conditions.

HBP units serve applications such as beverage cooling, refrigerated display cabinets, and liquid cooling. MBP units commonly serve walk-in coolers, salas de resfriamento, and chilled warehouses. Some applications overlap, so confirm the required evaporating temperature before selecting a model.

Não. Room temperature provides a starting point. Also confirm the design evaporating temperature, carga de resfriamento, and peak ambient temperature. The evaporator’s temperature difference and the product’s humidity requirements also influence unit selection.

Sim, when the compressor’s operating range covers both duty points. Check cooling capacity and power consumption at each point using the project’s refrigerant, temperatura de evaporação, and ambient temperature.

Start with the calculated cooling load in kW. Share the target temperature, insulation thickness, carga do produto, door-opening frequency, e condições ambientais. Our engineers use these details to select a unit that meets the project’s cooling demand.

Refrigerant options depend on the compressor and unit model, can choose from R404/507/448/449/290 and more.

YES.A suitable system can serve multiple evaporators when its capacity, tubulação, and controls match the application. Share each evaporator’s cooling load, operating temperature, and usage schedule so our engineers can review simultaneous demand and capacity control.

We offer standard and OEM refrigeration system. Share your destination market, tensão, fase, frequência, and any limits on cold room size or connection location. Para pedidos repetidos, ask us to confirm the model code and component list so you can re-order the same system.

Q9.Yes. Send the evaporator model, performance sheet, refrigerante, and expansion valve details. We check capacity at the same design evaporating temperature and review airflow, refrigerant control, and defrost requirements for your application.

Consider how much the cooling load changes during operation. Inverter units adjust compressor speed as demand changes. Non-inverter units use on/off control. Compare capacity, part-load operation, controles, and service requirements for your project.

Solicite um orçamento gratuito

Pronto para iniciar seu projeto conosco?

Seja nosso parceiro para aumentar a reputação da sua marca, obtenha uma experiência impressionante para que seus clientes se lembrem de você por toda a vida, e ajudá-lo a se destacar no mercado competitivo !

Produtos de refrigeração relacionados

Unidade de Condensação Hermética

Unidade de Condensação do Inversor

Unidade de condensação tipo caixa

Unidade Condensadora Semi Hemética

Unidade Monobloco Inversora

Unidade de Condensação de Sala Fria

O cálculo correto pode reduzir seu orçamento para câmaras frigoríficas

Calculadora de resfriamento de câmaras frias

Calculadora de armazenamento refrigerado

Estimar a capacidade de resfriamento & espessura do painel a partir das dimensões da sala
Dimensões da sala
m
m
m
Temperatura de armazenamento
Cenário de uso
Volume Total
0 m³
Capacidade de refrigeração
0 KW
Potência do Compressor
0 HP
Espessura do Painel
0 milímetros

Recomendações

  • ✓Painel: ...
  • ✓Compressor: ...
  • ✓Evaporador: ...
  • ✓Condensador: ...

Observação: Apenas referência preliminar. Consulte um profissional para o projeto final.

Não perca o melhor parceiro!

Pronto para trabalhar conosco?

Personalizamos os produtos de refrigeração superiores com base na sua ideia ou sugestão, uma vez que 2010