China HBP MBP Condensing Unit Manufacturer

Medium and high evaporating temperature condensing units for walk-in coolers, غرف التبريد, refrigerated display cabinets, and beverage coolers.

Speedway Refrigeration manufactures HBP MBP condensing units in China, with refrigerant options including R404/507/448/449/290, depending on the model. Share your application, required cooling capacity, design evaporating temperature, درجة الحرارة المحيطة, and power supply with our engineers to get a suitable unit selection and quotation.

شريكنا

محرك مروحة باناسونيك
ضاغط مانوروب
شعار شركة امبراكو
ضاغط بلايت
جدا
ضاغط تيكومسيه
كوبلاند
دانفوس
ضاغط refcomp
سانيو
شعار bitzer

What is the Difference Between HBP and MBP?

HBP stands for High Back Pressure and covers higher evaporating temperatures, such as beverage coolers and refrigerated display cabinets. MBP stands for Medium Back Pressure and covers medium evaporating temperatures, such as walk-in coolers and chiller rooms. The exact operating range depends on the unit model, المبردات, ونظام التبريد.

SelectionHBP — High Back PressureMBP — Medium Back Pressure
درجة حرارة التبخر−5°C to +15°C (23°F to 59°F)−20°C to 0°C (−4°F to 32°F)
التطبيقاتBeverage coolers, refrigerated display cabinets, and liquid coolingWalk-in coolers, غرف التبريد, and chilled goods storage
Capacity change from 25°C to 38°C ambientعن 16.3% lower at +5°C evaporating temperatureعن 17.1% lower at −10°C evaporating temperature
Checklist when selecting a unitCooling capacity at the design point and compressor operating limits at higher suction pressuresCooling capacity at the cooler design point and evaporator sizing

يلاحظ: The typical ranges overlap from −5°C to 0°C (23°F to 32°F). Use the project’s design evaporating temperature to read the performance table. Then check the specific condensing unit’s operating range and cooling capacity at your design ambient temperature and refrigerant.

HBP and MBP Models and Specifications

وحدة التكثيف المحكم-مع الشعار

For Chiller room and Walk-in chiller HBP Application

  • نطاق النموذج: Hermetic condensing unit

  • سلسلة الضاغط: العاكس الدوار / ضاغط التمرير

  • نطاق القدرة الحصانية: 4HP ~ 10HP

  • درجة حرارة التبخر: -5°C ~ +15°C

  • طلب: HBP

  • نطاق درجة حرارة الغرفة: 0°C ~ +10°C

  • درجة الحرارة المحيطة: Up to +42°C

  • الجهد االكهربى: 220الخامس / 380الخامس

  • مزود الطاقة: 1دكتوراه / 3دكتوراه, 50هرتز / 60هرتز

  • المبردات: R290 / R404 / R448 / R449

  • نوع المكثف: Air cooled finned copper coil condenser

  • خيار التحكم: وحدة تحكم رقمية LED

  • مطابقة تذويب: تذويب كهربائي أو تذويب الغاز الساخن

وحدة التكثيف المحكم-مع الشعار 1

For Refrigerated Cabnet and Chiller Room MBP Application

  • نطاق النموذج: وحدة تكثيف العاكس

  • سلسلة الضاغط: العاكس الدوار / ضاغط التمرير

  • نطاق القدرة الحصانية: 2HP ~ 5HP

  • درجة حرارة التبخر: +5درجة مئوية ~ -15 درجة مئوية

  • طلب: مب

  • نطاق درجة حرارة الغرفة: 0درجة مئوية ~ -10 درجة مئوية

  • درجة الحرارة المحيطة: تصل إلى +43 درجة مئوية

  • الجهد االكهربى: 220الخامس

  • مزود الطاقة: 1دكتوراه / 3دكتوراه, 50هرتز / 60هرتز

  • المبردات: R290 / R404 / R448 / R449

  • نوع المكثف: Air cooled finned copper coil condenser

  • خيار التحكم: وحدة تحكم رقمية LED

  • مطابقة تذويب: تذويب كهربائي أو تذويب الغاز الساخن

وحدة التكثيف المحكم-مع الشعار 3

For Walk-in Cooler, Beverage cooler and Chiller Room HBP MBP Application

  • نطاق النموذج: Box type condensing unit

  • سلسلة الضاغط: Non-inverter rotary / ضاغط التمرير

  • نطاق القدرة الحصانية: 8HP ~ 45HP

  • درجة حرارة التبخر: +10°C ~ -20°C

  • طلب: HBP, مب

  • نطاق درجة حرارة الغرفة: +5درجة مئوية ~ -18 درجة مئوية

  • درجة الحرارة المحيطة: حتى +45 درجة مئوية

  • الجهد االكهربى: 220الخامس / 380الخامس

  • مزود الطاقة: 1دكتوراه / 3دكتوراه, 50هرتز / 60هرتز

  • المبردات: R290 / R404 / R448 / R449

  • نوع المكثف: Air cooled finned copper coil condenser

  • خيار التحكم: وحدة تحكم رقمية LED

  • مطابقة تذويب: تذويب كهربائي أو تذويب الغاز الساخن

وحدة التكثيف من النوع H

For Walk-in cooler and Chiller Room HBP MBP Application

  • نطاق النموذج: H type condensing unit

  • سلسلة الضاغط: Non-inverter rotary / ضاغط التمرير

  • نطاق القدرة الحصانية: 3HP ~ 20HP

  • درجة حرارة التبخر: +5°C ~ -20°C

  • طلب: HBP, مب

  • نطاق درجة حرارة الغرفة: +0درجة مئوية ~ -15 درجة مئوية

  • درجة الحرارة المحيطة: تصل إلى +43 درجة مئوية

  • الجهد االكهربى: 220الخامس / 380الخامس

  • مزود الطاقة: 1دكتوراه / 3دكتوراه, 50هرتز / 60هرتز

  • المبردات: R290 / R404 / R448 / R449

  • نوع المكثف: Air cooled finned copper coil condenser

  • خيار التحكم: وحدة تحكم رقمية LED

  • مطابقة تذويب: تذويب كهربائي أو تذويب الغاز الساخن

وحدة تكثيف شبه محكم 03

For Chiller room and Walk-in chiller HBP Application

  • نطاق النموذج: وحدة تكثيف شبه محكم

  • سلسلة الضاغط: Non-inverter scroll compressor

  • نطاق القدرة الحصانية: 2HP ~ 40HP

  • درجة حرارة التبخر: +15درجة مئوية ~ -5 درجة مئوية

  • طلب: HBP

  • نطاق درجة حرارة الغرفة: 0°C ~ +15°C

  • درجة الحرارة المحيطة: حتى +45 درجة مئوية

  • الجهد االكهربى: 220الخامس / 380الخامس

  • مزود الطاقة: 1دكتوراه / 3دكتوراه, 50هرتز / 60هرتز

  • المبردات: R290 / R404 / R448 / R449

  • نوع المكثف: Air cooled finned copper coil condenser

  • خيار التحكم: وحدة تحكم رقمية LED

  • مطابقة تذويب: تذويب كهربائي أو تذويب الغاز الساخن

وحدة التكثيف من النوع V

For Refrigerated cooler room and Walk-in chiller HBP MBP Application

  • نطاق النموذج: V Type condensing unit

  • سلسلة الضاغط: Non-inverter scroll compressor

  • نطاق القدرة الحصانية: 5HP ~ 45HP

  • درجة حرارة التبخر: +10°C ~ -20°C

  • طلب: HBP, مب

  • نطاق درجة حرارة الغرفة: +10درجة مئوية ~ -18 درجة مئوية

  • درجة الحرارة المحيطة: حتى +45 درجة مئوية

  • الجهد االكهربى: 380الخامس

  • مزود الطاقة: 3دكتوراه, 50هرتز / 60هرتز

  • المبردات: R290 / R404 / R448 / R449

  • نوع المكثف: Air cooled finned copper coil condenser

  • خيار التحكم: وحدة تحكم رقمية LED

  • مطابقة تذويب: تذويب كهربائي أو تذويب الغاز الساخن

HBP & MBP Condensing Unit Applications

Speedway supplies HBP and MBP condensing units for walk-in coolers, غرف التبريد, refrigerated display cabinets, مبردات المشروبات, and chilled storage warehouses.

Walk-In Coolers and Chiller Rooms | مب

MBP units suit fresh produce, ألبان, and chilled food storage in supermarkets and foodservice facilities. Size the unit for the cooling load from incoming products, frequent door openings, and daily operating conditions.

Refrigerated Display Cabinets and Beverage Coolers | HBP or MBP

HBP and MBP units serve beverage coolers and chilled display cabinets, depending on the design evaporating temperature. Check cooling capacity, compressor operating limits, and condenser ventilation for the cabinet’s installation conditions.

Chilled Warehouses and Distribution Centers | مب

MBP units support chilled goods storage and distribution. Calculate each zone’s cooling load, account for product deliveries and loading activity, and check simultaneous demand when multiple evaporators share a refrigeration system.

سوبر ماركت 2
الفاكهة المعبأة المخزنة في غرفة باردة تجارية
يمكن الوصول إلى الفريزر 2

لماذا تختار وحدة التكثيف الخاصة بنا?

حدد النماذج بشكل أسرع حسب نطاق درجة الحرارة, نوع المشروع, والتطبيق.

اختر النماذج القياسية للطلبات العادية أو خيارات OEM للمشاريع المخصصة.

اضبط مخرجات التبريد بشكل أكثر سلاسة تحت حمل غرفة التغيير.

تحسين كفاءة التشغيل عندما لا تعمل الغرفة الباردة بكامل طاقتها.

تطابق الجهد المحلي, مرحلة, والتردد لأسواق التصدير المختلفة.

التعامل مع مشاريع المناخ الحار بأنظمة محيطة عالية مناسبة.

استخدم ضاغط كوبلاند/سانيو/عالي الطاقة الموفر للطاقة, لتوفير فاتورة لك إلى الأبد

نحن نفهم السوق الخاص بك ونطابق معدات التبريد مع ظروف التشغيل المحلية ومتطلبات العملاء.

Components with optimal Performance

Cold room condenser

High-efficiency Cold Room Condenser

Speedway cold room condenser copper coil combines durable copper tubing with precision-formed aluminum fins. Uniform fin spacing promotes even airflow, while tight contact between the tubes and fins ensures efficient heat transfer (30% higher than other suppleirs) and reliable heat rejection.

Embraco/Bitzer/Copeland/Dorin Compressor

We offer world famous compressor options for HBP and MBP condensing units, and match each compressor to the required cooling capacity, المبردات, درجة حرارة التبخر, and ambient conditions to support reliable operation.

ضاغط كوبلاند ايمرسون

Solid Condensing Unit Casing

Speedway rigid casing protects key components during handling and installation. Secure mounting points hold the compressor and condenser copper coil in position, while removable panels give technicians direct access for inspection and routine maintenance.

Cold Room Evaporators in Multiple Sizes

Speedway offer evaporators with fan diameters from 300 ل 800 mm and fin spacing from 4 ل 16 مم. We match copper coil capacity and airflow to the cooling load and operating temperature of each walk-in cooler or chiller room.

مبخر الغرفة الباردة
تصميم فريد من نوعه للوحة العاكسة بقوة 5 حصان

Smart Inverter Board with Self-Diagnostics

Speedway inverter board adjusts compressor speed to match cooling demand and monitors operating conditions in real time. Its self-diagnostics flag faults, helping technicians troubleshoot during commissioning and reduce downtime during service.

Accurate Temp Control

Our thermostat monitors cold room temperature and regulates cooling around the selected setpoint. This precise control limits temperature fluctuations and helps maintain stable conditions for both chilled and frozen products.

Thermostat for cold room

Production Workshop and Pre-Shipment Inspection

سبيدواي technicians assemble the refrigerant circuit and electrical controls, then inspect brazed joints, wiring connections, and component mounts. قبل الشحن, we conduct pressure hold tests and leak checks to verify refrigerant circuit integrity. We run the units to confirm compressor, معجب, and control operation, then secure them for handling and transport.

condensing unit inverter board

Keep Pressure and Anti-leak

Packed Condensing unit-ready to ship

Packed Condensing Unit-Ready to Ship

CDU Running Test before shippment

Condensing Unit Parameter Test at Pre-shipment

Key Technology and Performance Benefits

1.Enhanced Vapor Injection

Enhanced Vapor Injection(EVI) use plate heat exchanger subcools the liquid refrigerant in the main circuit while vaporizing refrigerant in a separate branch. The resulting intermediate-pressure vapor enters the compressor through a dedicated injection port.

In cold rooms, EVI increases cooling capacity at low evaporating temperatures, making it particularly suitable for walk-in freezers. It can also improve energy efficiency when the unit matches the operating conditions.

2.Variable-Speed Compressor

Speedway inverter condensing units automatically adjust compressor speed to match the cold room’s cooling load. After large deliveries or frequent door openings, they can increase cooling output to help the room return to its setpoint faster. At lower loads, they can run at reduced speed to reduce on/off cycling, limit temperature fluctuations, and cut part-load energy use.

3.High-Ambient Performance

We match the condenser and fans to maintain effective heat rejection in hot weather. Select models operate at outdoor ambient temperatures up to 50 درجة مئوية. We size each unit for the project’s peak outdoor temperature to help maintain the target cold room temperature during the hottest periods.

4.تذويب الغاز الساخن

تذويب الغاز الساخن is a method that directs hot refrigerant vapor from the compressor discharge through the evaporator coil to melt frost on the coil surface. Speedway condensing units use hot refrigerant vapor from the compressor to warm the evaporator coil from within and melt frost, reducing reliance on electric coil heaters. When we match the condensing unit to the evaporator, hot gas defrost can shorten cooling interruptions, restore airflow and cooling sooner, and limit the rise in cold room temperature during defrost.

الأسئلة الشائعة

HBP stands for High Back Pressure and covers higher evaporating temperatures. MBP stands for Medium Back Pressure and serves medium-temperature refrigeration. Select a unit by its operating range, المبردات, and cooling capacity at your design conditions.

HBP units serve applications such as beverage cooling, refrigerated display cabinets, and liquid cooling. MBP units commonly serve walk-in coolers, غرف التبريد, and chilled warehouses. Some applications overlap, so confirm the required evaporating temperature before selecting a model.

لا. Room temperature provides a starting point. Also confirm the design evaporating temperature, حمل التبريد, and peak ambient temperature. The evaporator’s temperature difference and the product’s humidity requirements also influence unit selection.

نعم, when the compressor’s operating range covers both duty points. Check cooling capacity and power consumption at each point using the project’s refrigerant, درجة حرارة التبخر, and ambient temperature.

Start with the calculated cooling load in kW. Share the target temperature, insulation thickness, تحميل المنتج, door-opening frequency, والظروف المحيطة. Our engineers use these details to select a unit that meets the project’s cooling demand.

Refrigerant options depend on the compressor and unit model, can choose from R404/507/448/449/290 and more.

YES.A suitable system can serve multiple evaporators when its capacity, الأنابيب, and controls match the application. Share each evaporator’s cooling load, operating temperature, and usage schedule so our engineers can review simultaneous demand and capacity control.

We offer standard and OEM refrigeration system. Share your destination market, الجهد االكهربى, مرحلة, تكرار, and any limits on cold room size or connection location. للطلبات المتكررة, ask us to confirm the model code and component list so you can re-order the same system.

Q9.Yes. Send the evaporator model, performance sheet, المبردات, and expansion valve details. We check capacity at the same design evaporating temperature and review airflow, refrigerant control, and defrost requirements for your application.

Consider how much the cooling load changes during operation. Inverter units adjust compressor speed as demand changes. Non-inverter units use on/off control. Compare capacity, part-load operation, الضوابط, and service requirements for your project.

طلب عرض أسعار مجاني

جاهز لبدء مشروعك معنا?

شارك معنا لزيادة سمعة علامتك التجارية, احصل على تجربة رائعة لعملائك ليتذكروك مدى الحياة, وتساعدك على التميز في السوق التنافسي !

منتجات التبريد ذات الصلة

وحدة التكثيف المحكم

وحدة التكثيف العاكس

وحدة التكثيف من النوع الصندوقي

وحدة التكثيف شبه الدموي

وحدة العاكس أحادية الكتلة

وحدة تكثيف الغرفة الباردة

الحساب الصحيح يمكن أن يقلل من ميزانية غرفتك الباردة

حاسبة تبريد الغرفة الباردة

حاسبة التخزين البارد

تقدير قدرة التبريد & سمك اللوحة من أبعاد الغرفة
أبعاد الغرفة
م
م
م
درجة حرارة التخزين
سيناريو الاستخدام
الحجم الإجمالي
0 م³
قدرة التبريد
0 KW
قوة الضاغط
0 HP
سماكة اللوح
0 مم

التوصيات

  • ✓لوحة: ...
  • ✓ضاغط: ...
  • ✓المبخر: ...
  • ✓مكثف: ...

ملحوظة: مرجع أولي فقط. استشارة المهنية للتصميم النهائي.

لا تفوت أفضل شريك!

جاهز للعمل معنا?

نحن نقوم بتخصيص منتجات التبريد المتميزة بناءً على فكرتك أو اقتراحك منذ ذلك الحين 2010