Medium and high evaporating temperature condensing units for walk-in coolers, холодильные камеры, refrigerated display cabinets, and beverage coolers.
Speedway Refrigeration manufactures HBP MBP condensing units in China, with refrigerant options including R404/507/448/449/290, depending on the model. Share your application, required cooling capacity, design evaporating temperature, температура окружающей среды, and power supply with our engineers to get a suitable unit selection and quotation.
HBP stands for High Back Pressure and covers higher evaporating temperatures, such as beverage coolers and refrigerated display cabinets. MBP stands for Medium Back Pressure and covers medium evaporating temperatures, such as walk-in coolers and chiller rooms. The exact operating range depends on the unit model, хладагент, и система охлаждения.
| Selection | HBP — High Back Pressure | MBP — Medium Back Pressure |
|---|---|---|
| Температура испарения | −5°C to +15°C (23°F to 59°F) | −20°C to 0°C (−4°F to 32°F) |
| Приложения | Beverage coolers, refrigerated display cabinets, and liquid cooling | Walk-in coolers, холодильные камеры, and chilled goods storage |
| Capacity change from 25°C to 38°C ambient | О 16.3% lower at +5°C evaporating temperature | О 17.1% lower at −10°C evaporating temperature |
| Checklist when selecting a unit | Cooling capacity at the design point and compressor operating limits at higher suction pressures | Cooling capacity at the cooler design point and evaporator sizing |
Уведомление: The typical ranges overlap from −5°C to 0°C (23°F to 32°F). Use the project’s design evaporating temperature to read the performance table. Then check the specific condensing unit’s operating range and cooling capacity at your design ambient temperature and refrigerant.
For Chiller room and Walk-in chiller HBP Application
Модельный ряд: Hermetic condensing unit
Серия компрессоров: Инвертор поворотный / спиральный компрессор
Диапазон мощности: 4HP ~ 10HP
Температура испарения: -5°C ~ +15°C
Приложение: ХБП
Диапазон комнатной температуры: 0°C ~ +10°C
Температура окружающей среды: Up to +42°C
Напряжение: 220В / 380В
Источник питания: 1Ph / 3Ph, 50Гц / 60Гц
Хладагенты: 290 рэндов / Р404 / 448 рэндов / R449
Тип конденсатора: Air cooled finned copper coil condenser
Вариант управления: Светодиодный цифровой контроллер
Согласование разморозки: Электрическое размораживание или размораживание горячим газом.
For Refrigerated Cabnet and Chiller Room MBP Application
Модельный ряд: Инвертор конденсирующий блок
Серия компрессоров: Инвертор поворотный / спиральный компрессор
Диапазон мощности: 2HP ~ 5HP
Температура испарения: +5°С ~ -15°С
Приложение: ПМБ
Диапазон комнатной температуры: 0° C ~ -10 ° C.
Температура окружающей среды: До +43°С
Напряжение: 220В
Источник питания: 1Ph / 3Ph, 50Гц / 60Гц
Хладагенты: 290 рэндов / Р404 / 448 рэндов / R449
Тип конденсатора: Air cooled finned copper coil condenser
Вариант управления: Светодиодный цифровой контроллер
Согласование разморозки: Электрическое размораживание или размораживание горячим газом.
For Walk-in Cooler, Beverage cooler and Chiller Room HBP MBP Application
Модельный ряд: Box type condensing unit
Серия компрессоров: Non-inverter rotary / спиральный компрессор
Диапазон мощности: 8HP ~ 45HP
Температура испарения: +10°C ~ -20°C
Приложение: ХБП, ПМБ
Диапазон комнатной температуры: +5°С ~ -18°С
Температура окружающей среды: До +45°С
Напряжение: 220В / 380В
Источник питания: 1Ph / 3Ph, 50Гц / 60Гц
Хладагенты: 290 рэндов / Р404 / 448 рэндов / R449
Тип конденсатора: Air cooled finned copper coil condenser
Вариант управления: Светодиодный цифровой контроллер
Согласование разморозки: Электрическое размораживание или размораживание горячим газом.
For Walk-in cooler and Chiller Room HBP MBP Application
Модельный ряд: H type condensing unit
Серия компрессоров: Non-inverter rotary / спиральный компрессор
Диапазон мощности: 3HP ~ 20HP
Температура испарения: +5°C ~ -20°C
Приложение: ХБП, ПМБ
Диапазон комнатной температуры: +0°С ~ -15°С
Температура окружающей среды: До +43°С
Напряжение: 220В / 380В
Источник питания: 1Ph / 3Ph, 50Гц / 60Гц
Хладагенты: 290 рэндов / Р404 / 448 рэндов / R449
Тип конденсатора: Air cooled finned copper coil condenser
Вариант управления: Светодиодный цифровой контроллер
Согласование разморозки: Электрическое размораживание или размораживание горячим газом.
For Chiller room and Walk-in chiller HBP Application
Модельный ряд: Полугерметичный конденсаторный блок
Серия компрессоров: Non-inverter scroll compressor
Диапазон мощности: 2HP ~ 40HP
Температура испарения: +15°С ~ -5°С
Приложение: ХБП
Диапазон комнатной температуры: 0°C ~ +15°C
Температура окружающей среды: До +45°С
Напряжение: 220В / 380В
Источник питания: 1Ph / 3Ph, 50Гц / 60Гц
Хладагенты: 290 рэндов / Р404 / 448 рэндов / R449
Тип конденсатора: Air cooled finned copper coil condenser
Вариант управления: Светодиодный цифровой контроллер
Согласование разморозки: Электрическое размораживание или размораживание горячим газом.
For Refrigerated cooler room and Walk-in chiller HBP MBP Application
Модельный ряд: V Type condensing unit
Серия компрессоров: Non-inverter scroll compressor
Диапазон мощности: 5HP ~ 45HP
Температура испарения: +10°C ~ -20°C
Приложение: ХБП, ПМБ
Диапазон комнатной температуры: +10°С ~ -18°С
Температура окружающей среды: До +45°С
Напряжение: 380В
Источник питания: 3Ph, 50Гц / 60Гц
Хладагенты: 290 рэндов / Р404 / 448 рэндов / R449
Тип конденсатора: Air cooled finned copper coil condenser
Вариант управления: Светодиодный цифровой контроллер
Согласование разморозки: Электрическое размораживание или размораживание горячим газом.
Speedway supplies HBP and MBP condensing units for walk-in coolers, холодильные камеры, refrigerated display cabinets, охладители напитков, and chilled storage warehouses.
Walk-In Coolers and Chiller Rooms | ПМБ
MBP units suit fresh produce, молочный, and chilled food storage in supermarkets and foodservice facilities. Size the unit for the cooling load from incoming products, frequent door openings, and daily operating conditions.
Refrigerated Display Cabinets and Beverage Coolers | HBP or MBP
HBP and MBP units serve beverage coolers and chilled display cabinets, depending on the design evaporating temperature. Check cooling capacity, compressor operating limits, and condenser ventilation for the cabinet’s installation conditions.
Chilled Warehouses and Distribution Centers | ПМБ
MBP units support chilled goods storage and distribution. Calculate each zone’s cooling load, account for product deliveries and loading activity, and check simultaneous demand when multiple evaporators share a refrigeration system.
Выбирайте модели быстрее по температурному диапазону, тип проекта, и приложение.
Выбирайте стандартные модели для регулярных заказов или варианты OEM для индивидуальных проектов..
Более плавно регулируйте мощность охлаждения при нагрузке в разной комнате..
Повышение эффективности работы, когда холодильная камера не работает с полной нагрузкой.
Соответствуйте местному напряжению, фаза, и частота для различных экспортных рынков.
Реализация проектов в жарком климате с использованием подходящих систем для высоких температур окружающей среды..
Используйте энергосберегающий компрессор Copeland/Sanyo/Highly., чтобы сохранить твои счета навсегда
Мы понимаем ваш рынок и подбираем холодильное оборудование к местным условиям эксплуатации и требованиям клиентов..
High-efficiency Cold Room Condenser
Speedway cold room condenser copper coil combines durable copper tubing with precision-formed aluminum fins. Uniform fin spacing promotes even airflow, while tight contact between the tubes and fins ensures efficient heat transfer (30% higher than other suppleirs) and reliable heat rejection.
Embraco/Bitzer/Copeland/Dorin Compressor
We offer world famous compressor options for HBP and MBP condensing units, and match each compressor to the required cooling capacity, хладагент, температура испарения, and ambient conditions to support reliable operation.
Solid Condensing Unit Casing
Speedway rigid casing protects key components during handling and installation. Secure mounting points hold the compressor and condenser copper coil in position, while removable panels give technicians direct access for inspection and routine maintenance.
Cold Room Evaporators in Multiple Sizes
Speedway offer evaporators with fan diameters from 300 к 800 mm and fin spacing from 4 к 16 мм. We match copper coil capacity and airflow to the cooling load and operating temperature of each walk-in cooler or chiller room.
Smart Inverter Board with Self-Diagnostics
Speedway inverter board adjusts compressor speed to match cooling demand and monitors operating conditions in real time. Its self-diagnostics flag faults, helping technicians troubleshoot during commissioning and reduce downtime during service.
Accurate Temp Control
Our thermostat monitors cold room temperature and regulates cooling around the selected setpoint. This precise control limits temperature fluctuations and helps maintain stable conditions for both chilled and frozen products.
Спидвей technicians assemble the refrigerant circuit and electrical controls, then inspect brazed joints, wiring connections, and component mounts. Перед отправкой, we conduct pressure hold tests and leak checks to verify refrigerant circuit integrity. We run the units to confirm compressor, вентилятор, and control operation, then secure them for handling and transport.
Keep Pressure and Anti-leak
Packed Condensing Unit-Ready to Ship
Condensing Unit Parameter Test at Pre-shipment
1.Enhanced Vapor Injection
Enhanced Vapor Injection(EVI) use plate heat exchanger subcools the liquid refrigerant in the main circuit while vaporizing refrigerant in a separate branch. The resulting intermediate-pressure vapor enters the compressor through a dedicated injection port.
In cold rooms, EVI increases cooling capacity at low evaporating temperatures, making it particularly suitable for walk-in freezers. It can also improve energy efficiency when the unit matches the operating conditions.
2.Variable-Speed Compressor
Speedway inverter condensing units automatically adjust compressor speed to match the cold room’s cooling load. After large deliveries or frequent door openings, they can increase cooling output to help the room return to its setpoint faster. At lower loads, they can run at reduced speed to reduce on/off cycling, limit temperature fluctuations, and cut part-load energy use.
3.High-Ambient Performance
We match the condenser and fans to maintain effective heat rejection in hot weather. Select models operate at outdoor ambient temperatures up to 50 °С. We size each unit for the project’s peak outdoor temperature to help maintain the target cold room temperature during the hottest periods.
4.Оттайка горячим газом
Оттайка горячим газом is a method that directs hot refrigerant vapor from the compressor discharge through the evaporator coil to melt frost on the coil surface. Speedway condensing units use hot refrigerant vapor from the compressor to warm the evaporator coil from within and melt frost, reducing reliance on electric coil heaters. When we match the condensing unit to the evaporator, hot gas defrost can shorten cooling interruptions, restore airflow and cooling sooner, and limit the rise in cold room temperature during defrost.
HBP stands for High Back Pressure and covers higher evaporating temperatures. MBP stands for Medium Back Pressure and serves medium-temperature refrigeration. Select a unit by its operating range, хладагент, and cooling capacity at your design conditions.
HBP units serve applications such as beverage cooling, refrigerated display cabinets, and liquid cooling. MBP units commonly serve walk-in coolers, холодильные камеры, and chilled warehouses. Some applications overlap, so confirm the required evaporating temperature before selecting a model.
Нет. Room temperature provides a starting point. Also confirm the design evaporating temperature, охлаждающая нагрузка, and peak ambient temperature. The evaporator’s temperature difference and the product’s humidity requirements also influence unit selection.
Да, when the compressor’s operating range covers both duty points. Check cooling capacity and power consumption at each point using the project’s refrigerant, температура испарения, and ambient temperature.
Start with the calculated cooling load in kW. Share the target temperature, insulation thickness, загрузка продукта, door-opening frequency, и условия окружающей среды. Our engineers use these details to select a unit that meets the project’s cooling demand.
Refrigerant options depend on the compressor and unit model, can choose from R404/507/448/449/290 and more.
YES.A suitable system can serve multiple evaporators when its capacity, трубопровод, and controls match the application. Share each evaporator’s cooling load, operating temperature, and usage schedule so our engineers can review simultaneous demand and capacity control.
We offer standard and OEM refrigeration system. Share your destination market, Напряжение, фаза, частота, and any limits on cold room size or connection location. Для повторных заказов, ask us to confirm the model code and component list so you can re-order the same system.
Q9.Yes. Send the evaporator model, performance sheet, хладагент, and expansion valve details. We check capacity at the same design evaporating temperature and review airflow, refrigerant control, and defrost requirements for your application.
Consider how much the cooling load changes during operation. Inverter units adjust compressor speed as demand changes. Non-inverter units use on/off control. Compare capacity, part-load operation, элементы управления, and service requirements for your project.
Сотрудничайте с нами, чтобы повысить репутацию вашего бренда, получите впечатляющий опыт, чтобы ваши клиенты запомнили вас на всю жизнь, и помочь вам выделиться на конкурентном рынке !
Правильный расчет может сократить бюджет вашей холодильной камеры.
Примечание: Только предварительная информация. Проконсультируйтесь с профессионалом для окончательного дизайна.
Мы настраиваем превосходную холодильную продукцию на основе вашей идеи или предложения, поскольку 2010