스피드웨이 로고

China HBP MBP Condensing Unit Manufacturer

Medium and high evaporating temperature condensing units for walk-in coolers, 냉각기 방, refrigerated display cabinets, and beverage coolers.

Speedway Refrigeration manufactures HBP MBP condensing units in China, with refrigerant options including R404/507/448/449/290, depending on the model. Share your application, required cooling capacity, design evaporating temperature, 주변 온도, and power supply with our engineers to get a suitable unit selection and quotation.

우리의 파트너

파나소닉 팬 모터
기동 압축기
엠브라코 로고
블레이트 압축기
고도로
테쿰세 컴프레서
코프랜드
댄포스
참조 압축기
산요
비트저 로고

What is the Difference Between HBP and MBP?

HBP stands for High Back Pressure and covers higher evaporating temperatures, such as beverage coolers and refrigerated display cabinets. MBP stands for Medium Back Pressure and covers medium evaporating temperatures, such as walk-in coolers and chiller rooms. The exact operating range depends on the unit model, 냉각제, 및 냉동 시스템.

SelectionHBP — High Back PressureMBP — Medium Back Pressure
증발 온도−5°C to +15°C (23°F to 59°F)−20°C to 0°C (−4°F to 32°F)
응용 프로그램Beverage coolers, refrigerated display cabinets, and liquid coolingWalk-in coolers, 냉각기 방, and chilled goods storage
Capacity change from 25°C to 38°C ambient에 대한 16.3% lower at +5°C evaporating temperature에 대한 17.1% lower at −10°C evaporating temperature
Checklist when selecting a unitCooling capacity at the design point and compressor operating limits at higher suction pressuresCooling capacity at the cooler design point and evaporator sizing

알아채다: The typical ranges overlap from −5°C to 0°C (23°F to 32°F). Use the project’s design evaporating temperature to read the performance table. Then check the specific condensing unit’s operating range and cooling capacity at your design ambient temperature and refrigerant.

HBP and MBP Models and Specifications

밀폐형 응축 장치 - 로고 포함

For Chiller room and Walk-in chiller HBP Application

  • 모델 범위: Hermetic condensing unit

  • 압축기 시리즈: 인버터 로터리 / 스크롤 압축기

  • 마력 범위: 4HP ~ 10HP

  • 증발 온도: -5°C ~ +15°C

  • 애플리케이션: HBP

  • 실내 온도 범위: 0°C ~ +10°C

  • 주변 온도: Up to +42°C

  • 전압: 220V / 380V

  • 전원 공급 장치: 1Ph / 3Ph, 50Hz / 60Hz

  • 냉매: R290 / R404 / R448 / R449

  • 콘덴서 유형: Air cooled finned copper coil condenser

  • 제어 옵션: LED 디지털 컨트롤러

  • 제상 매칭: 전기 제상 또는 핫가스 제상

밀폐형 응축 장치 - 로고 포함 1

For Refrigerated Cabnet and Chiller Room MBP Application

  • 모델 범위: 인버터 응축 장치

  • 압축기 시리즈: 인버터 로터리 / 스크롤 압축기

  • 마력 범위: 2HP ~ 5HP

  • 증발 온도: +5°C ~ -15°C

  • 애플리케이션: MBP

  • 실내 온도 범위: 0°C ~ -10°C

  • 주변 온도: 최대 +43°C

  • 전압: 220V

  • 전원 공급 장치: 1Ph / 3Ph, 50Hz / 60Hz

  • 냉매: R290 / R404 / R448 / R449

  • 콘덴서 유형: Air cooled finned copper coil condenser

  • 제어 옵션: LED 디지털 컨트롤러

  • 제상 매칭: 전기 제상 또는 핫가스 제상

밀폐형 응축 장치 - 로고 포함 3

For Walk-in Cooler, Beverage cooler and Chiller Room HBP MBP Application

  • 모델 범위: Box type condensing unit

  • 압축기 시리즈: Non-inverter rotary / 스크롤 압축기

  • 마력 범위: 8HP ~ 45HP

  • 증발 온도: +10°C ~ -20°C

  • 애플리케이션: HBP, MBP

  • 실내 온도 범위: +5°C ~ -18°C

  • 주변 온도: 최대 +45°C

  • 전압: 220V / 380V

  • 전원 공급 장치: 1Ph / 3Ph, 50Hz / 60Hz

  • 냉매: R290 / R404 / R448 / R449

  • 콘덴서 유형: Air cooled finned copper coil condenser

  • 제어 옵션: LED 디지털 컨트롤러

  • 제상 매칭: 전기 제상 또는 핫가스 제상

H형 응축 장치

For Walk-in cooler and Chiller Room HBP MBP Application

  • 모델 범위: H type condensing unit

  • 압축기 시리즈: Non-inverter rotary / 스크롤 압축기

  • 마력 범위: 3HP ~ 20HP

  • 증발 온도: +5°C ~ -20°C

  • 애플리케이션: HBP, MBP

  • 실내 온도 범위: +0°C ~ -15°C

  • 주변 온도: 최대 +43°C

  • 전압: 220V / 380V

  • 전원 공급 장치: 1Ph / 3Ph, 50Hz / 60Hz

  • 냉매: R290 / R404 / R448 / R449

  • 콘덴서 유형: Air cooled finned copper coil condenser

  • 제어 옵션: LED 디지털 컨트롤러

  • 제상 매칭: 전기 제상 또는 핫가스 제상

반밀폐형 콘덴싱 유닛 03

For Chiller room and Walk-in chiller HBP Application

  • 모델 범위: 반밀폐형 콘덴싱 유닛

  • 압축기 시리즈: Non-inverter scroll compressor

  • 마력 범위: 2HP ~ 40HP

  • 증발 온도: +15°C ~ -5°C

  • 애플리케이션: HBP

  • 실내 온도 범위: 0°C ~ +15°C

  • 주변 온도: 최대 +45°C

  • 전압: 220V / 380V

  • 전원 공급 장치: 1Ph / 3Ph, 50Hz / 60Hz

  • 냉매: R290 / R404 / R448 / R449

  • 콘덴서 유형: Air cooled finned copper coil condenser

  • 제어 옵션: LED 디지털 컨트롤러

  • 제상 매칭: 전기 제상 또는 핫가스 제상

V형 응축 장치

For Refrigerated cooler room and Walk-in chiller HBP MBP Application

  • 모델 범위: V Type condensing unit

  • 압축기 시리즈: Non-inverter scroll compressor

  • 마력 범위: 5HP ~ 45HP

  • 증발 온도: +10°C ~ -20°C

  • 애플리케이션: HBP, MBP

  • 실내 온도 범위: +10°C ~ -18°C

  • 주변 온도: 최대 +45°C

  • 전압: 380V

  • 전원 공급 장치: 3Ph, 50Hz / 60Hz

  • 냉매: R290 / R404 / R448 / R449

  • 콘덴서 유형: Air cooled finned copper coil condenser

  • 제어 옵션: LED 디지털 컨트롤러

  • 제상 매칭: 전기 제상 또는 핫가스 제상

HBP & MBP Condensing Unit Applications

Speedway supplies HBP and MBP condensing units for walk-in coolers, 냉각기 방, refrigerated display cabinets, 음료 쿨러, and chilled storage warehouses.

Walk-In Coolers and Chiller Rooms | MBP

MBP units suit fresh produce, 낙농, and chilled food storage in supermarkets and foodservice facilities. Size the unit for the cooling load from incoming products, frequent door openings, and daily operating conditions.

Refrigerated Display Cabinets and Beverage Coolers | HBP or MBP

HBP and MBP units serve beverage coolers and chilled display cabinets, depending on the design evaporating temperature. Check cooling capacity, compressor operating limits, and condenser ventilation for the cabinet’s installation conditions.

Chilled Warehouses and Distribution Centers | MBP

MBP units support chilled goods storage and distribution. Calculate each zone’s cooling load, account for product deliveries and loading activity, and check simultaneous demand when multiple evaporators share a refrigeration system.

슈퍼마켓 2
상업용 냉장실에 보관된 과일 상자
손이 닿는 냉장고 2

콘덴싱 유닛을 선택해야 하는 이유?

온도 범위에 따라 더 빠르게 모델 선택, 프로젝트 유형, 및 적용.

일반 주문의 경우 표준 모델을 선택하고 맞춤형 프로젝트의 경우 OEM 옵션을 선택하세요..

실내 부하 변화에 따라 냉각 출력을 보다 원활하게 조정.

냉장실이 최대 부하로 작동하지 않을 때 운영 효율성 향상.

지역 전압 일치, 단계, 다양한 수출 시장에 대한 빈도.

적합한 높은 대기 시스템으로 더운 기후 프로젝트를 처리하세요..

에너지 절약형 Copeland/Sanyo/Highly 압축기 사용, 청구서를 영원히 절약하기 위해

우리는 귀하의 시장을 이해하고 냉동 장비를 현지 운영 조건 및 고객 요구 사항에 맞춰드립니다..

Components with optimal Performance

Cold room condenser

High-efficiency Cold Room Condenser

Speedway cold room condenser copper coil combines durable copper tubing with precision-formed aluminum fins. Uniform fin spacing promotes even airflow, while tight contact between the tubes and fins ensures efficient heat transfer (30% higher than other suppleirs) and reliable heat rejection.

Embraco/Bitzer/Copeland/Dorin Compressor

We offer world famous compressor options for HBP and MBP condensing units, and match each compressor to the required cooling capacity, 냉각제, 증발 온도, and ambient conditions to support reliable operation.

Copeland Emerson 압축기

Solid Condensing Unit Casing

Speedway rigid casing protects key components during handling and installation. Secure mounting points hold the compressor and condenser copper coil in position, while removable panels give technicians direct access for inspection and routine maintenance.

Cold Room Evaporators in Multiple Sizes

Speedway offer evaporators with fan diameters from 300 에게 800 mm and fin spacing from 4 에게 16 mm. We match copper coil capacity and airflow to the cooling load and operating temperature of each walk-in cooler or chiller room.

찬 방 증발기
독특한 디자인의 5HP 인버터 보드

Smart Inverter Board with Self-Diagnostics

Speedway inverter board adjusts compressor speed to match cooling demand and monitors operating conditions in real time. Its self-diagnostics flag faults, helping technicians troubleshoot during commissioning and reduce downtime during service.

Accurate Temp Control

Our thermostat monitors cold room temperature and regulates cooling around the selected setpoint. This precise control limits temperature fluctuations and helps maintain stable conditions for both chilled and frozen products.

Thermostat for cold room

생산 워크샵 및 선적 전 검사

고속 도로 기술자가 냉매 회로와 전기 제어 장치를 조립합니다., 그런 다음 브레이징 조인트를 검사하십시오., 배선 연결, 및 구성 요소 마운트. 선적 전, 우리는 냉매 회로의 무결성을 확인하기 위해 압력 유지 테스트와 누출 점검을 수행합니다.. 압축기를 확인하기 위해 장치를 가동합니다., 팬, 및 제어 작동, 그런 다음 취급 및 운송을 위해 보안을 유지합니다..

집광 장치 인버터 보드

압력 유지 및 누출 방지

포장된 응축 장치 - 배송 준비 완료

포장된 응축 장치 - 배송 준비 완료

CDU 출고 전 테스트 실행

선적 전 응축 단위 매개 변수 테스트

주요 기술 및 성능 이점

1.강화된 증기 주입

강화된 증기 주입(EVI) 판형 열 교환기를 사용하여 주 회로의 액체 냉매를 과냉각시키는 동시에 별도의 분기에서 냉매를 기화시킵니다.. 생성된 중간압 증기는 전용 분사 포트를 통해 압축기로 들어갑니다..

냉장실에서, EVI는 낮은 증발 온도에서 냉각 용량을 증가시킵니다., 워크인 냉동고에 특히 적합합니다.. 또한 장치가 작동 조건과 일치하면 에너지 효율을 향상시킬 수 있습니다..

2.가변 속도 압축기

Speedway 인버터 응축 장치 냉장실의 냉각 부하에 맞게 압축기 속도를 자동으로 조정합니다.. 대량 배송 또는 문을 자주 여는 경우, 냉각 출력을 높여 실내가 설정 지점으로 더 빨리 돌아갈 수 있도록 돕습니다.. 낮은 부하에서, 온/오프 사이클링을 줄이기 위해 감소된 속도로 실행할 수 있습니다., 온도 변동을 제한하다, 부분 부하 에너지 사용을 줄입니다..

3.높은 주변 성능

더운 날씨에도 효과적인 방열을 유지하기 위해 콘덴서와 팬을 일치시킵니다.. 일부 모델은 최대 실외 주변 온도에서 작동합니다. 50 °C. 우리는 가장 더운 기간 동안 목표 냉장실 온도를 유지하는 데 도움이 되도록 프로젝트의 최고 실외 온도에 맞게 각 장치의 크기를 조정합니다..

4.핫가스 제상

핫가스 제상 압축기 토출에서 나오는 뜨거운 냉매 증기를 증발기 코일을 통해 유도하여 코일 표면의 성에를 녹이는 방식입니다.. 스피드웨이 응축 장치 압축기에서 나오는 뜨거운 냉매 증기를 사용하여 증발기 코일 내부를 따뜻하게 하고 성에를 녹입니다., 전기 코일 히터에 대한 의존도 감소. 응축 장치를 증발기에 맞출 때, 핫가스 제상으로 냉각 중단 시간을 단축할 수 있습니다., 공기 흐름과 냉각을 더 빨리 복원, 제상 중 냉장실 온도 상승을 제한합니다..

FAQ

HBP stands for High Back Pressure and covers higher evaporating temperatures. MBP stands for Medium Back Pressure and serves medium-temperature refrigeration. Select a unit by its operating range, 냉각제, and cooling capacity at your design conditions.

HBP units serve applications such as beverage cooling, refrigerated display cabinets, and liquid cooling. MBP units commonly serve walk-in coolers, 냉각기 방, and chilled warehouses. Some applications overlap, so confirm the required evaporating temperature before selecting a model.

아니요. Room temperature provides a starting point. Also confirm the design evaporating temperature, 냉각 부하, and peak ambient temperature. The evaporator’s temperature difference and the product’s humidity requirements also influence unit selection.

예, when the compressor’s operating range covers both duty points. Check cooling capacity and power consumption at each point using the project’s refrigerant, 증발 온도, and ambient temperature.

Start with the calculated cooling load in kW. Share the target temperature, insulation thickness, 제품로드, door-opening frequency, 및 주변 조건. Our engineers use these details to select a unit that meets the project’s cooling demand.

Refrigerant options depend on the compressor and unit model, can choose from R404/507/448/449/290 and more.

YES.A suitable system can serve multiple evaporators when its capacity, 관, and controls match the application. Share each evaporator’s cooling load, operating temperature, and usage schedule so our engineers can review simultaneous demand and capacity control.

We offer standard and OEM refrigeration system. Share your destination market, 전압, 단계, 빈도, and any limits on cold room size or connection location. 반복 주문의 경우, ask us to confirm the model code and component list so you can re-order the same system.

Q9.Yes. Send the evaporator model, performance sheet, 냉각제, and expansion valve details. We check capacity at the same design evaporating temperature and review airflow, refrigerant control, and defrost requirements for your application.

Consider how much the cooling load changes during operation. Inverter units adjust compressor speed as demand changes. Non-inverter units use on/off control. Compare capacity, part-load operation, 통제 수단, and service requirements for your project.

무료 견적 요청

우리와 함께 프로젝트를 시작할 준비가 되었습니다.?

귀하의 브랜드 평판을 높이기 위해 저희와 협력하십시오, 고객이 평생 기억할 인상적인 경험을 얻으십시오., 경쟁 시장에서 두각을 나타낼 수 있도록 도와드립니다. !

관련 냉동 제품

올바른 계산으로 냉장실 예산을 줄일 수 있습니다

냉장실 냉각 계산기

냉장 보관 계산기

냉각 용량 추정 & 방 치수의 패널 두께
객실 크기
중
중
중
보관 온도
사용 시나리오
총량
0 중³
냉방 능력
0 KW
압축기 전력
0 HP
패널 두께
0 mm

권장 사항

  • ✓패널: ...
  • ✓압축기: ...
  • ✓증발기: ...
  • ✓콘덴서: ...

메모: 예비 참고용. 최종 디자인은 전문가에게 문의하세요..

최고의 파트너를 놓치지 마세요!

우리와 함께 일할 준비가?

우리는 귀하의 아이디어나 제안을 바탕으로 우수한 냉동 제품을 맞춤화합니다. 2010