Inverter condensing unit uses variable-speed control to adjust compressor output based on the actual cooling load.
Instead of running at one fixed speed all the time, it changes capacity as room demand changes.
This helps the system keep room temperature more stable, reduce frequent start-stop cycles, and improve efficiency during part-load operation.
It works especially well in cold rooms with changing load, ouverture fréquente des portes, day-night temperature swings, or strict temperature control needs.
Inverter condensing units work best in projects with changing load, long daily running hours, or higher temperature control requirements.
They don’t fit every cold room project, so correct selection matters.
| Suitable Applications | Why It Fits | Less Suitable Applications | Why It Not Fit |
|---|---|---|---|
| Cold rooms with frequent door opening | Load changes often during the day, so inverter compressor helps the unit adjust faster | Projects with very stable load all day | A non-inverter unit can offer a simpler solution |
| Fresh produce storage | Better temperature stability helps protect product quality | Projects with very tight initial budget | The buyer may focus more on first cost than operating efficiency |
| Food processing rooms | Room load changes with workflow, personnes, and door traffic | Simple replacement jobs with limited control upgrade | The site may not support the full value of inverter system |
| Distribution and logistics cold rooms | The system often faces variable cooling demand | Remote areas with weak service support | Buyers may prefer simpler components and easier service |
| Multi-purpose cold rooms | Different products and room use can create fluctuating demand | Small projects with short daily running time | Energy-saving return may not be strong enough |
| Projects with high electricity cost | Better part-load performance can improve operating cost | Buyers who want only the lowest purchase price | Product value may not match the buying target |
| Projects that require lower noise | Inverter operation can reduce noise under part-load conditions | Projects with fixed operating condition and simple control target | The system may not need variable capacity control |
| Projects that need tighter temperature control | The unit can adjust capacity more smoothly | Sites with unstable power quality and no proper protection plan | The project may need extra electrical review before selection |
Choose the right inverter condensing unit series by room temperature, cooling load, conditions ambiantes, réfrigérant, and project type.
A correct selection helps you balance temperature, energy performance, les coûts d'installation, and long-term service support.
For applications that need stable cooling in the 0°C à +15°C range.
| Modèle | HP | Température ambiante | Réfrigérant | Source de courant | Key Advantage | Suitable For |
|---|---|---|---|---|---|---|
| SWICDU2H | 2HP | +5°C à +15°C | R290/R404A | 220V/1Ph/50/60Hz | Compact size, faible bruit | Beverage room, flower room |
| SWICDU3H | 3HP | +2°C to +12°C | R290/R404A | 220V/1Ph/50/60Hz | Stable temperature control | Fresh food room, dairy room |
| SWICDU5H | 5HP | 0°C à +10°C | R290/R404A | 380V/3Ph/50/60Hz | Better part-load efficiency | Produce room, food prep room |
| SWICDU8H | 8HP | 0°C à +10°C | R290/R404A | 380V/3Ph/50/60Hz | Stronger cooling for larger rooms | Salle de traitement, commercial storage |
| SWICDU10H | 10HP | 0°C to +8°C | R290/R404A | 380V/3Ph/50/60Hz | Good for long daily operation | Large fresh storage projects |
Basic Parameters
Gamme de modèles: Inverter condensing unit models
Série de compresseurs: Inverter rotary / scroll compressor
Gamme de puissance: 2HP to 10HP
Température d'évaporation: +5°C à -10°C
Température d'application: Haute température
Room Temperature Range: 0°C à +15°C
Température ambiante: Up to +43°C, option ambiante élevée disponible
Tension: 220V / 380V
Source de courant: 1Ph. / 3Ph., 50hertz / 60hertz
Réfrigérants: R290a / R404A / R448A / R449A
Type d'installation: Monté au sol / Extérieur
Type d'unité: Air cooled inverter condensing unit
Type de condensateur: Condenseur à serpentin à ailettes refroidi par air
Option de contrôle: LED digital controller
Defrost Matching: Electric defrost or Hot gas defrost
Dimensions: Dépend de la puissance du compresseur et de la taille du condenseur
For standard cold room applications in the -10°C à +5°C range.
Modèle | HP | Température ambiante | Réfrigérant | Source de courant | Key Advantage | Suitable For |
|---|---|---|---|---|---|---|
| SWICDU2M | 2HP | 0°C à +5°C | R290/R404A | 220V/1Ph/50/60Hz | Small footprint, installation facile | Petite chambre froide |
| SWICDU3M | 3HP | -2°C à +5°C | R290/R404A | 220V/1Ph/50/60Hz | Stable operation for daily use | Convenience cold room |
| SWICDU5M | 5HP | -10°C à +5°C | R290/R404A | 380V/3Ph/50/60Hz | Better load matching | Meat prep room, produce room |
| SWICDU8M | 8HP | -10°C à +5°C | R290/R404A | 380V/3Ph/50/60Hz | Higher efficiency in long-hour use | Medium commercial cold room |
| SWICDU10M | 10HP | -10°C à +5°C | R290/R404A | 380V/3Ph/50/60Hz | Strong cooling output | Large cold storage room |
| SWICDU12M | 12HP | -10°C à +5°C | R290/R404A | 380V/3Ph/50/60Hz | Good for project matching | Food processing and storage |
Basic Parameters
Gamme de modèles: Inverter condensing unit models
Série de compresseurs: Inverter rotary / scroll compressor
Gamme de puissance: 2HP to 12HP
Température d'évaporation: 0°C to -20°C
Température d'application: Température moyenne
Room Temperature Range: -10°C à +5°C
Température ambiante: Up to +43°C, option ambiante élevée disponible
Tension: 220V / 380V
Source de courant: 1Ph. / 3Ph., 50hertz / 60hertz
Réfrigérants: R290a / R404A / R448A / R449A
Type d'installation: De plein air
Type d'unité: Air cooled inverter condensing unit
Type de condensateur: Condenseur à serpentin à ailettes refroidi par air
Option de contrôle: LED digital controller
Defrost Matching: Electric defrost or hot gas defrost
Dimensions: Dépend de la puissance du compresseur et de la taille du condenseur
For freezer rooms and frozen storage in the -18°C à -25°C range.
| Modèle | HP | Température ambiante | Réfrigérant | Source de courant | Key Advantage | Suitable For |
|---|---|---|---|---|---|---|
| SWICDU3L | 3HP | -18°C to -20°C | R404A/R448A | 380V/3Ph/50/60Hz | Reliable entry model for freezer rooms | Small freezer room |
| SWICDU5L | 5HP | -18°C to -22°C | R404A/R448A | 380V/3Ph/50/60Hz | Stable low-temp cooling | Frozen meat room |
| SWICDU8L | 8HP | -20°C à -25°C | R404A/R448A | 380V/3Ph/50/60Hz | Better performance for heavier load | Seafood freezer room |
| SWICDU10L | 10HP | -20°C à -25°C | R404A/R448A | 380V/3Ph/50/60Hz | Stronger output for large rooms | Frozen food warehouse |
| SWICDU12L | 12HP | -20°C à -25°C | R404A/R448A | 380V/3Ph/50/60Hz | Good for long-hour freezer use | Distribution freezer room |
| SWICDU15L | 15HP | -20°C à -25°C | R404A/R448A | 380V/3Ph/50/60Hz | Project-ready for larger systems | Industrial cold storage |
Basic Parameters
Gamme de modèles: Inverter condensing unit models
Série de compresseurs: Inverter scroll compressor
Gamme de puissance: 3HP à 15HP
Température d'évaporation: -15°C à -35°C
Température d'application: Basse température
Room Temperature Range: -18°C à -25°C
Température ambiante: Up to +43°C, option ambiante élevée disponible
Tension: 380V / 415V / 460V
Source de courant: 3Ph., 50hertz / 60hertz
Réfrigérants: R404A / R507 / R448A / R449A
Type d'installation: De plein air
Type d'unité: Air cooled inverter condensing unit
Type de condensateur: Condenseur à serpentin à ailettes refroidi par air
Option de contrôle: LED digital controller
Defrost Matching: Electric defrost or hot gas defrost
Dimensions: Dépend de la puissance du compresseur et de la taille du condenseur
For buyers who need custom system and project, brand labeling, or project-based design.
| Modèle | HP | Température ambiante | Réfrigérant | Source de courant | Key Advantage | Suitable For |
|---|---|---|---|---|---|---|
| SWICDU3O | 3HP | High/medium/low | R290/R404A/Custom | Coutume | Flexible entry OEM option | Local distributors |
| SWICDU5O | 5HP | High/medium/low | R290/R404A/Custom | Coutume | Good for repeat OEM orders | Brand owners |
| SWICDU8O | 8HP | High/medium/low | R290/R404A/Custom | Coutume | Better for project matching | Entrepreneurs |
| SWICDU10O | 10HP | High/medium/low | R290/R404A/Custom | Coutume | Supports more configuration options | Cold room builders |
| SWICDU12O | 12HP | High/medium/low | R290/R404A/Custom | Coutume | Good for engineering projects | Project contractors |
| SWICDU15O | 15HP | High/medium/low | R290/R404A/Custom | Coutume | Suitable for larger OEM demand | Industrial buyers |
Basic Parameters
Gamme de modèles: OEM inverter condensing unit models
Série de compresseurs: Inverter piston/scroll compressor
Gamme de puissance: 3HP à 15HP
Température d'évaporation: +5°C à -35°C
Température d'application: Haut / moyen / basse température
Room Temperature Range: Coutume
Température ambiante: Up to +43°C, option ambiante élevée disponible
Tension: 220V / 380V / 415V / 460V
Source de courant: 1Ph. / 3Ph., 50hertz / 60hertz
Réfrigérants: R290a / R404A / R448A / R449A
Type d'installation: Monté au sol
Type d'unité: Air cooled inverter condensing unit
Type de condensateur: Condenseur à serpentin à ailettes refroidi par air
Option de contrôle: LED digital controller
Defrost Matching: Electric defrost or hot gas defrost
Dimensions: Dépend de la puissance du compresseur et de la taille du condenseur
By Room Temperature
Chambre froide: 0°C à +10°C, for produce, laitier, boissons, and fresh storage
Salle de congélation: -18°C to -15°C, for frozen food, viande, and seafood
Deep Freezer Room: -25°C à -35°C, for deep frozen products and long-term low-temperature storage
Par méthode de refroidissement
Air-Cooled: installation facile, practical for most standard cold room projects
Water-Cooled: better fit for hot climates and indoor mechanical rooms
Evaporative Type: stronger heat rejection for larger and more demanding projects
By Structure
Open Type (Semi-hermetic): easier service access for project installations
Box Type: compact cabinet design for outdoor use and better protection
Compact Outdoor Type: space-saving layout for standard cold room applications
Par réfrigérant
R404A: for many low-temperature and replacement applications
R448A / R449A: for compliance-focused and retrofit projects
Other Options: available for selected markets and project needs
By Buyer Type
Pour les distributeurs: standard models, Marque OEM, spare parts planning
Pour les installateurs: easier matching, câblage, and commissioning
For Contractors: flexible project configuration and technical support
For OEM Buyers: stable specification, custom labeling, and repeat production
Inverter condensing unit can save max 50% energy and cooling time, most suitable for voltage un-stable area, never damage compressor
Carte d'unité de condensation à inverseur
Tableau d'affichage personnalisé
Carte d'entraînement d'onduleur supérieure
Carte principale d'onduleur personnalisée
Lunette de vue
Filtre Sécheur
Séparateur d'huile
Vanne Danfoss TXV
| Conception | Valeurs |
|---|---|
| Séparateur d'huile à haute efficacité et capillaire de retour d'huile précis | Réduire la quantité d'huile de réfrigérant de compresseur entrant dans le système de réfrigération dans l'ordre pour améliorer l'efficacité de réfrigération, Évitez le fonctionnement déficient en huile, Assurer la durée de vie du compresseur et protéger la sécurité du compresseur |
| Valve d'expansion électronique double | Réponse d'ajustement rapide, Contrôle précis de la température de stockage, et une protection à haute température pour assurer l'état de fonctionnement optimal du compresseur |
| Séparateur à gaz-liquide | Évitez le réfrigérant liquide entrant dans la chambre de compression et le compresseur de dommages lorsque la température ambiante et la température de stockage du froid sont faibles |
| Capteur de haute précision | Adapter différentes conditions de travail de haute ou basse température ou différents éléments stockés, avec une précision de contrôle de la température de ± 0,5 ℃ |
| Capteur à haute pression | Surveillez le fonctionnement du compresseur pour éviter efficacement la surcharge du compresseur tout en garantissant le compresseur optimal et l'état de réfrigération dans toutes les conditions, et ajustez de manière adaptative les paramètres de fonctionnement du compresseur et du moteur en fonction de l'efficacité d'évaporation du réfrigérant |
| CFD Air Conception de conception de 480㎜ Diamètre | Bruit bas, grand volume d'air, efficacité d'échange thermique élevée |
| Moteur CC sans balais avec contrôle de vitesse sans étape | Plus d'énergie, Contrôle de charge plus précis de l'unité d'onduleur, Réglage automatique de la vitesse en fonction de la demande de charge pour assurer une efficacité de condensation optimale et augmenter la capacité de refroidissement |
| La carte d'affichage peut personnaliser les informations de votre entreprise | Personnalisez les informations en fonction de votre demande, aider les clients à améliorer leur visibilité sur le marché, et rendre les clients potentiels plus faciles à trouver les informations de votre entreprise |
| Pression de basse du dos spéciale (LBP) Compresseur d'onduleur à basse température | Un taux de compression élevé peut assurer la durabilité, et garantir l'ensemble de l'unité durable et stable sous une température ambiante élevée et une faible température de stockage ou une faible température ambiante et des conditions de température de stockage basse |
| Diaphragme Conception de la clandestins à un chemin à parcours | Lorsque la chambre froide atteint la température réglée, Empêcher le réfrigérant dans le condenseur qui remonte dans le compresseur et provoquer une limace liquide à endommager le compresseur quand il recommence |
Our inverter condensing units fit a wide range of cold room projects:
Fruit and vegetable cold rooms, where stable temperature helps preserve freshness.
Meat and seafood cold rooms, where reliable cooling performance supports product safety.
Dairy and beverage cold rooms, where load can change during daily operation.
Food processing rooms, where door opening and work flow often create fluctuating load.
Pharma and chemical cold rooms, where users need tighter control and stable operation.
Cold chain logistics and distribution centers, where the system often faces changing room demand.
Please send us your room size, température ambiante, product type, température ambiante, alimentation, et conditions d'installation. If you have drawings or BOQ (Bill of Quantity), you can send them with your inquiry. Our team can recommend a suitable series and model based on your project.
High temp series usually fits applications from 0°C to +15°C. Medium temp series usually fits applications from -10°C to +5°C. Low temp series usually fits freezer room applications from -18°C to -25°C. If you are not sure which series fits your project, send us your room temperature and use case.
Oui. Inverter condensing units can work well in freezer room applications when the model matches the required room temperature, réfrigérant, and cooling load. Low temp series usually suits frozen food, viande, and seafood storage projects.
Not in every project. Energy performance depends on room insulation, evaporator selection, conditions ambiantes, control setting, fréquence d'ouverture des portes, and daily load changes. Inverter units usually show more value in projects with variable load and long daily running hours.
Oui. We can select a matching solution based on evaporator model, température ambiante, réfrigérant, and project condition. This helps reduce capacity mismatch and supports more stable system performance.
Oui, dans de nombreux cas. But we need to check refrigerant, température ambiante, evaporator model, état de la tuyauterie, alimentation, and cooling capacity first. A replacement project needs full system matching, not only compressor HP matching.
We support common export power supply options such as 220V, 380V, 415V, and 460V, with 1Ph or 3Ph, 50Hz ou 60Hz, depend on the model and project requirement. If your market uses a special power standard, please tell us before order confirmation.
Oui. We can offer units for hot climate projects and high ambient (>+45°C) installation extérieure. Please send your local ambient temperature, température ambiante, and installation location before quotation.
Oui. We can support OEM branding, plaque, emballage, tension, réfrigérant, structure type, and other project-based configurations. This option fits distributors, entrepreneurs, and customers with repeat orders or non-standard project requirements.
Please send your room size, température ambiante cible, product type, température ambiante, alimentation, refrigerant requirement, and installation location. If you already have drawings, BOQ, or evaporator information, please include them in your inquiry. Clear project information helps us recommend the right model and prepare a faster quotation.
Associez-vous à nous pour augmenter la réputation de votre marque, obtenez une expérience impressionnante pour que vos clients se souviennent de vous toute leur vie, et vous aider à vous démarquer sur le marché concurrentiel !
Nous personnalisons les produits de réfrigération supérieurs en fonction de votre idée ou suggestion depuis 2010