One-Stop OEM & ODM Cold Room Solution Partner

Our China Factory Fabricates Inverter & Non-inverter Condensing Unit As Your Demand

We customize all types condensing unit with different sizes and materials 0.5~50hp, show us the technical data or drawing, we will follow and satisfy you.
Cooperate with Outstanding Companies Makes You Better

Our Partnership

Panasonic fan motor
Embraco logo
Maneurop Compressor
Blait compressor
danfoss
tecumseh compressor
Copeland
Highly
refcomp compressor
SANYO
bitzer logo

What is Condensing Unit?

Condensing units (also called”refrigeration unit” or “cold room outdoor unit”) are used for refrigeration of various equipments. Main components: compressor, condenser, expansion valve, fan motor, control board, pipeline system, etc.

Compressor is the core component in condensing unit, usually called “main engine”. Refrigerant changes from low pressure to high pressure, the continuous flow and transport are all accomplished by the work of compressor.

Bitzer Piston semi-hermetic condensing unit

Condensing Unit Manufacturer

Condensing unit factory

Speedway is a condensing unit manufacturer in China, produce both inverter and non-inverter condensing unit.

Our factory manufactures condensing unit 0.5~50hp, of course also can customize your requirements. Our equipments are suitable for Cold Room, cold storage, container,  hospital drug cold chain, seafood cold chain, cafe room, or any other commercial purpose places in where you want to cooling the space.

What’s more, we also produce Cold Room Panel, Cold Room Door, Unit Cooler (evaporator), Monoblock Refrigeration Unit, Reach-in Refrigerator, drying room panel which equipped with our condensing unit or your existing cooling system.

Warmly wish to cooperate with you.

Custom Refrigeration Condensing Unit

Cold room structure

Cold Room Panel and Refrigeration Unit

Custom Condensing Unit

Self-Contained Refrigeration Unit

Semi-hermetic scroll refrigeration unit

Semi-Hermetic Condensing Unit

Super low temp condensing unit

Super Low Temp Refrigeration Unit

Monoblock Condensing unit

Monoblock Refrigeration Unit

Refrigeration units

Inverter Condensing Unit

Mobile Refrigeration Unit

Mobile Refrigeration Unit

Copeland Hermetic Condensing Unit

Hermetic Condensing Unit

Reach in freezer-front side

Reach-in Refrigerator

We Can Help You Seize More Potential Markets

High Quality Components Help You Unbeatable

Clients Priority, Quality is Everything! We have 6 production lines for condensing unit, use world famous brand compressor and parts to ensure every unit ranked top quality.

Why Choose Our Condensing Unit?

Inverter Condensing Unit Can Save 50% Energy and Cooling Time

Excellent Energy-Save Condensing Unit

Most Suitable For Voltage Un-stable Area, Never Damage Compressor

Inverter CDU

Inverter CDU Board

Custom Display

Custom Display

Unique Design 5HP Inverter Board

Superior Inverter Electric Board

Custom Inveter Board

Custom Inverter Board

Sight Glass

Sight Glass

Filter Drier 1

Filter Dryer

Oil Separator 1

Oil Separator

Expansion Valve 1

TXV Valve

Condensing Unit Super Cooling
How Does Condensing Unit Work?
Condensing Unit Circuit Diagram
Condensing Unit Circuit Diagram

Condensing Unit Application

Condensing unit mainly used for food storage, pharmaceutical storage, flowers, chemical storage, hotel industry, cold chain logistics, wine storage, seedling cultivation, supermarkets, and other industries. Meanwhile, used for the production, storage and logistics for all kinds of food, agricultural products and other commodities which needed a constant temperature environment.

Crab cold storage

Seafood 

flower storage

Flower

Seedling Cultivation

Seedling Cultivation

chemical storage

Chemical Material

Agriculture Products

Agriculture 

Cold Chain Transportation

Cold Chain

pharmaceutical storage

Pharmaceutical

wine storage

Wine

How Condensing Unit Connect to Control Box?

control-box-indoor-unit-outdoor-unit-connection-diagram
Control Box Electrical Connection Diagram

Control box line color :

Red is “5” 
Yellow is “7”      
Green is “8”     
Blue is “9”   
Brown is “10”    
Black is “12”  

Attention: The colors only demonstrate how to connect different terminals properly, not cables’ color.

Outdoor unit: Cold room condensing unit circuit diagram

Indoor unit: Cold room Unit Cooler (evaporator) circuit diagram

Attention: For original whole diagram, please Contact Us freely.

How to Count Condensing Unit HP ?

Want to Calculate the Condensing Unit Horsepower (HP) for Your Project?

No worry, our cooling capacity tonnage calculator will help you !

Considerations When Buying Condensing Unit

When you want to wholesale condensing unit,or act as a dealers.

# Firstly you should double think some questions: what is your selling market features? What is your selling channels? Who is your competitor? etc. they are very important for us before giving you the final solution.

Condensing Unit 2hp

#1 Application

If you want to cool a whole project for cold room, container (20ft/40ft), supermarket, the household split type air conditioners are not suitable. As their application areas are so different.

Application areas for condensing unit:

2hp 10~20㎡; 3hp 15~25㎡

4hp 20~40㎡; 5hp 30~55㎡

6hp 40~80㎡, etc.

(HP means Horse Power)

Due to working temperature ( high, medium, low) the application areas are different even the same HP.

So please give your drawings and all information, we will supply you the solution.

#2 Refrigerant 

Different refrigerants have different prices, and most countries forbade R22 refrigerant (Not R22 compressor), so double check your market or government the related policy, don’t make big mistake.

For condensing unit or refrigeration unit, there are more refrigerants’ options, like R404, R448a, R134a, R449a, etc. Let’s know your option or project details.

#3 Inverter or Non-inverter

Most people are puzzled by two types cooling way: inverter or non-inverter. In one word: Inverter condensing unit is more energy-saving, more stable, more bigger cooling area, better for low and unstable voltage areas. Of course, price is higher.

#4 Pricing

According to different working temperature & room size, we will recommend the most suitable & competitive refrigeration products.

What’s more, different compressors ( Copeland / Bitzer / Sanyo / Panasonic / Highly ) have different prices.

For condensing unit or refrigeration unit, you can choose from 0.5~50hp or even more.

Inverter condensing unit is higher price than non-inverter condensing unit.

#5 Reputation

Before confirming the order, should first verify the authenticity of supplier, if possible please visit the factory before purchasing
the products. What’s more, can ask some sample to test then you will have a brief understanding about this company and their managenment.

Emerson_FFAP

#6 Set Temperature

Different stored goods have different temperature requsts, and the cooling power is also different.

For example, frozen foods such as ice cream requires -18°C, transport of chilled meat requires -5°C, and the required temperature for fresh fruits and vegetables is also different. Especially for the cold chain transportation of vaccines and medicines, which need special temperature <-35℃.

Therefore, need to select suitable condensing unit or refrigeration unit according to different temperature requests.

In addition, some goods also require the refrigeration unit to have a defrosting function during transportation.

#7 Hermetic Way

Cold room refrigeration compressors can be divided into two types: semi-hermetic and hermetic due to their structure.

1) Semi-hermetic refrigeration compressor:
Adapt a wider pressure range and cooling capacity. Thermal efficiency is higher, cooling effect is more stable, and the unit power consumption is less. But the price is much expensive.

2) Hermetic refrigeration compressor:
The compressor and motor are installed in a welded or brazed shell, and share a main shaft, which not only cancels the shaft sealing device (decrease the possibility of leaks), but also greatly reduces size and weight of the entire compressor. But its price is cheaper than the semi-hermetic type.

Checklists For Qualified Condensing Unit

#1 Package

Brand new condensing unit should use hard and sturdy wooden (Fumigation Free) package, firmly fixed. No broken or damage.

#2 Casing

Normally use zinc plated iron sheet, which has anti-rust function. The more even plated, the more better function of anti-rust. Of course, you can use stainless steel (SS) material, neven corrosion, but price is much higher. 

Bitzer Piston semi-hermetic condensing unit

#3 Component Condition

All parts should be brand new, especially the compressor, some suppliers use 2nd-hand or refurbished compressor to cheat clients, whose quality is very unstable.

#4 Welding

Qualified products will have dwell time for pressure one week or more before delivery to prevent any refrigerant leakage. Bad welding will easily leak refrigerant, made big money loss for clients.

#5 Compressor Type

Less than 3hp usually use rotary compressor ( Copeland / Sanyo / Highly ), more than 3hp use scroll compressor ( hermetic condensing unit) or piston compressor ( semi-hermetic condensing unit). Inverter condensing unit 2hp ~ 9hp all use ROTARY compressor (Sanyo / Highly).

Copeland Emerson compressor

#6 Noise

Brand new evaporator & condensing unit shouldn’t have a big noise (more than 45 dBA) when runs in 30 minutes, otherwise the compressor or fan (motor) uses poor quality, this kind of evaporator or condensing unit is not qualified.

#7 Voltage and Frequency

Condensing unit less than 3hp uses 220V normally ,but we also supply 380V. More than 3hp usually adopt 380-440V. What’s more, you should confirm your frequency , 50Hz or 60Hz, the unit price is different and misuse will damage your compressor even the whole condensing unit.

Notice: We can customize your Voltage.

The FAQs

Frequently Asked Questions About Condensing Unit

Condensing unit is responsible for condensing refrigerant vapor into liquid form by releasing heat, allowing the refrigeration system to remove heat from the desired space, finally cool down the room.

Speedway is committed to quality across all aspects of our business – our people, processes and products. We call this ‘the SPEEDWAY  standard’.

Condensing unit receives high-pressure, high-temperature refrigerant vapor from the compressor. Refrigerant flows through the condenser coil, where it releases heat to the surrounding air or water, causing it to condense into a liquid, finally cooling the space or medium.

We welcome any sample order before big quantity purchase, that means 1pc is acceptable. For mass order quantity is 10pcs each model.

The two main types of condensers used in condensing units are air-cooled condenser, which use fans to blow air over the condenser coil, and water-cooled condenser, which circulate water to remove heat from the refrigerant.

We have own factory to produce the main refrigeration products, but we also do trading for other related products because we have resource to supply good quality and service.

Sizing a condensing unit involves determining the cooling capacity required for the specific application. Factors such as the desired temperature, ambient conditions, and the type of refrigerant will determine the appropriate capacity.

For details request please email us: sales@cn-beyond.com 

Yes,we have 5 senior engineers, 13 professional r & D team, 65 professional production personnel.

Regular maintenance of condensing unit includes cleaning the condenser coil, checking and replacing air filters, inspecting electrical connections, ensuring compressor proper lubrication,etc. It’s also important to monitor and maintain the appropriate refrigerant levels (use Sight Glass).

We support payment through wire transfer, like T/T, L/C, Western Union. Also accpet Paypal payment for sample piece order.

For sure. You can send us your logo, package, design, drawing, technical specification, we will give you the final satisfied solution accordingly without additional cost !

Common issues include refrigerant leaks, compressor failures, fan motor malfunctions, clogged condenser coils, or issues with control and safety devices. Regular maintenance and Prompt Troubleshooting can help address these problems.

Yes, we did. Our factory has inner 100% inspection for each unit before loading, also can make the legal test report for each shippment. What’s more, can invite SGS / TUV / BV inspection according clients’ request, but customers should pay for the test fee.

First, we need starting the business to understand each other, if things move smoothly and you meet our “distributor request”, then we will sign the formal contract and agreement to ensure your rights in your market.

Contact our salesman for more details please.

Yes. But indoor condensing units require proper ventilation and additional considerations for air circulation and condensate drainage.

The lifetime depend on factors such as maintenance, usage, and environmental conditions. On average, a well-maintained condensing unit can last 12~15 years or more.

It’s important to follow appropriate safety measures such as disconnecting power before performing maintenance or repairs, wearing personal protective equipment (PPE), and following proper handling procedures for refrigerants to prevent injury or accidents.

Request A Free Quote

Ready to Start Your Project Wth Us?

Partner with us to increase your brand reputation, get an impressive experience for your clients to remember you lifelong, and help you stand out in the competitive market !

Don’t Miss Out on the Best OEM Partner!

Ready to Work With Us?

Experience our difference and Take the first step toward a better future for your business!