Penghawa Dingin Kalis Letupan

kategori

Ciri-ciri Produk:

ATEX Series Explosion Proof

Explosion-Proof Construction

Sealed Electrical Components

High Temperature Rating

Corrosion Resistance

Explosion-Proof Motors

Intrinsically Safe Controls

Certifications

Remote Monitoring and Control

Efficient Cooling

Customization Options

Penerangan

What is explosion proof air conditioner?

Explosion-proof air conditioner is a special cooling system to operate safely in environments where there’s a risk of explosion due to the presence of flammable gases, vapors, or dust.

These Penghawa dingin are built with materials and features that prevent sparks or other ignition sources from causing explosions in hazardous areas.

Explosion proof air conditioner classification

Explosion-proof air conditioners are classified according to the hazardous environments they operate in. The classification is typically based on the type of hazardous substances present and the likelihood of an explosion occurring.

Class I: This classification pertains to locations where flammable gases or vapors are present in quantities sufficient to produce explosive or ignitable mixtures.

Class I is further divided into:

Class I, Division 1 (Div 1): Areas where flammable concentrations of gases or vapors are likely to exist under normal operating conditions.

Class I, Division 2 (Div 2): Areas where flammable concentrations of gases or vapors are not likely to exist under normal operating conditions, but may occasionally be present.Wall Split Explosion proof air conditioner

Class II: This classification applies to locations where combustible dust is present in sufficient quantities to potentially produce explosive mixtures.

Class II is further divided into:

Class II, Division 1 (Div 1): Areas where combustible dust is regularly present in sufficient quantities to create a hazardous atmosphere.

Class II, Division 2 (Div 2): Areas where combustible dust is not normally present in sufficient quantities to create a hazardous atmosphere, but may occasionally accumulate and become a hazard.

Class III: This classification covers locations where ignitable fibers or flyings may be present but are not likely to be suspended in the air in quantities sufficient to produce ignitable mixtures.

Explosion proof air conditioner control

Class III is further divided into:

Class III, Division 1 (Div 1): Areas where ignitable fibers or flyings are present in quantities sufficient to create a hazardous atmosphere under normal operating conditions.

Class III, Division 2 (Div 2): Areas where ignitable fibers or flyings are not normally present in quantities sufficient to create a hazardous atmosphere, but may accumulate and become a hazard under abnormal conditions.

Explosion Proof Air Conditioner Parameter

ModelBKFR-26GW/1HPBKFR-35GW/1.5HPBKFR-50GW/2HPBKFR-72GW/3HP
FungsiCool and HeatCool and HeatCool and HeatCool and Heat
Cooling capacity power2650W3500W5000W7200W
Heating capacity power2920W3850W5800W8000W
Power supply220V/50Hz220V/50Hz220V/50Hz220/380V/50Hz
Cooling input power810W1068W1600W2350W
Heating input power810W1200W1680W2650W
Electric heat power900W1000W1200W1000W
Kelantangan(m3/j)5416318511101
bising(indoor/outdoor) dB35-40/40-4937-42/42-5132-40-5339-48-57
Water proof gradeIPX4IPX4IPX4IPX4
Suitable area10-18 m215-24 m222-34 m235-50 m2
Indoor unit dimension776*268*186mm844*300*183mm940*298*200mm1078*326*253mm
Outdoor unit dimension776*540*320mm848*540*320mm995*700*396mm980*790*427mm

What is the main difference between normal air conditioner and explosion proof air conditioner?

Ciri-ciri keselamatan

Penghawa Dingin Biasa:

Standard air conditioners don’t incorporate safety features to prevent explosions in hazardous environments.

Explosion-Proof Air Conditioner:

Explosion-proof air conditioners have safety features such as sealed enclosures for electrical components, explosion-resistant materials, and special motors and controls that minimize the risk of sparking or overheating in potentially explosive atmospheres.

Intended Use

Penghawa Dingin Biasa:

Standard air conditioners are suitable for use in residential, komersial, and industrial places where there is no risk of explosion from flammable gases, vapors, or dust.

Explosion-Proof Air Conditioner:

Explosion-proof air conditioners are specifically used in hazardous environments where the presence of flammable gases, vapors, or combustible dust poses a risk of explosion. They are commonly used in industries such as oil and gas, chemical processing, farmaseutikal, and mining.

Floor Standing Explosion proof air conditioner

Floor standing explosion proof air conditioner 01

Enclosures and Sealing

Penghawa Dingin Biasa:

Standard Air Conditioners have open or partially enclosed electrical components, which may allow sparks or arcs to escape and potentially ignite flammable substances.

Explosion-Proof Air Conditioner:

Explosion-proof air conditioners feature fully sealed enclosures for electrical components to prevent any sparks, arcs, or heat from escaping and igniting hazardous substances in the surrounding environment.

Materials and Construction

Penghawa Dingin Biasa:

Standard air conditioners are often constructed using materials like plastic or lightweight metals, which may not withstand the rigors of hazardous environments or provide sufficient protection against explosions.

Wall split explosion proof air conditioner 01

Explosion-Proof Air Conditioner:

Explosion-proof air conditioners are built with robust materials such as stainless steel or aluminum alloys, which offer enhanced durability and resistance to corrosion and can withstand the conditions of hazardous areas.

Cost and Investment:

Penghawa Dingin Biasa:

Standard Air Conditioners are generally more affordable for use in non-hazardous environments.

Explosion-Proof Air Conditioner:

Explosion-proof air conditioners are special equipment for use in hazardous locations, and as such, they typically come with a higher initial cost due to their specialized construction, components, and certification requirements.

Wall Split Explosion proof air conditioner 03

FAQs

1. Can explosion-proof air conditioners operate in extreme temperatures?

ya, many explosion-proof air conditioners can operate effectively in extreme temperatures, ranging from very low temperatures in arctic environments to high temperatures in desert regions. These units are equipped with robust components and insulation to withstand harsh temperature conditions.

2.Do explosion-proof air conditioners require specialized installation?

ya, should have expertise person, who is familiar with the requirements of hazardous locations and applicable regulatory standards, to make the installation. Proper installation ensures the units are positioned correctly and follow all safety measures.

Wall Split Explosion proof air conditioner 02

3. Can explosion-proof air conditioners be used in outdoor environments?

ya, explosion-proof air conditioners can be used in outdoor environment. These units have weatherproof enclosures and components to withstand exposure to elements such as rain, wind, and sunlight.

4. What are the maintenance requirements for explosion-proof air conditioners?

Maintenance requirements include: routine checks, filter replacement, cleaning of components, and inspection of seals and enclosures to ensure continued safe operation.

Maintenance procedures should be carried out according to Pengeluar Penghawa Dingin regulatory guidelines.

Proses Pesanan OEM

Langkah 1

Buat Rancangan Anda

Berikan penyelesaian untuk memenuhi permintaan unik anda, dan buat karya seni untuk kelulusan anda.

Langkah 2

Kelulusan Sampel

Pertama kami akan menghantar sampel kepada anda dengan kelulusan, masa penghantaran adalah 7-10 hari bekerja selepas mendapat bayaran sampel anda.

Langkah 3

Letakkan Pesanan

Butiran pesanan adalah berdasarkan sampel, kita boleh mulakan perniagaan dengan kuantiti yang kecil, dan harga unit bergantung pada kuantiti yang berbeza.

Langkah 4

Pengeluaran Kuantiti Beramai-ramai

Pengeluaran besar-besaran biasanya memerlukan 30-50 hari , bergantung pada kuantiti akhir anda.

Langkah 5

Penghantaran Pesanan

Dihantar melalui laut, udara, atau kurier. 100% pemeriksaan sebelum penghantaran.

Mengenai Syarikat Kami

Kumpulan Litar Lumba China ialah produk HVACR profesional’ pengilang dan pemborong, kami menyesuaikan produk dan alat ganti HVACR yang berbeza, terutamanya produk dan bahagian penyejukan. Seperti penghawa dingin, peralatan penyejukan, mesin ais, penyahlembapan, kipas enjin, penukar haba, aksesori penyejukan, dan lain-lain.

Seperti yang bekerja dalam bidang HVACR sejak itu 2010, kami mempunyai lebih banyak pengalaman boleh memberikan anda produk dan penyelesaian yang unik, juga akan membekalkan caj percuma sepanjang hayat sokongan teknikal. Amat mengalu-alukan pertanyaan kami dengan sampel anda, lukisan atau reka bentuk, matlamat kami adalah menjadikan idea anda menjadi kenyataan dan memberi manfaat kepada anda.

Apa lagi, untuk pelanggan kami, kami akan mendapatkan produk lain, mengesahkan pembekal, berunding dengan mereka dengan caj percuma untuk anda.

Lagi Mengenai Produk Kami

Kipas Motor

Penyaman Udara

Unit Pemeluwapan

Unit Penyejuk

Bilik sejuk

Dehumidifier

Mesin Ais

Kami Ingin Bekerjasama Dengan Anda

Hantar mesej kepada kami jika anda mempunyai sebarang pertanyaan atau meminta sebut harga. Pakar kami akan memberi anda jawapan dalam masa 24 jam dan membantu anda memilih produk yang betul.

Jangan Terlepas Rakan Kongsi OEM Terbaik!

Sedia Bekerja Dengan Kami?

Alami perbezaan kami dan Ambil langkah pertama ke arah masa depan yang lebih baik untuk perniagaan anda!