Hermetic condensing unit combines a hermetic compressor, 콘덴서, 팬, and essential control and protection components into one refrigeration unit. Buyers often use this type of unit in chiller rooms, 냉동실, and other commercial or light industrial refrigeration projects because it offers a compact structure and practical project integration.
도매업자용, 계약자, and installers, the value of a hermetic condensing unit goes beyond the sealed compressor design. In the right capacity range and application, it helps standardize procurement, simplify delivery, and support faster project execution. Buyers should choose this type of unit based on room temperature, 주변 조건, operating load, service strategy, and market requirements instead of price alone.
Common Applications
Chiller rooms
Freezer rooms
Fruit and vegetable storage
고기 및 해산물 저장
Supermarket back rooms
Food service and processing cold rooms
A suitable condensing unit depends on room temperature, 방 크기, 주변 조건, 냉각제, 전압, installation environment, and application needs. We review project data first, then recommend a model that fits the operating condition instead of using rough horsepower estimates.
Choose by Room Temperature
Medium Temperature Units: for -15°C to +5°C cold rooms
Low Temperature Units: for -15°C to -35°C freezer applications
Choose by Application
Fruit and vegetable storage
Meat freezing
Seafood storage
유제품 및 음료실
Supermarket and food service cold rooms
Process cooling support
Choose by Installation Environment
Outdoor projects
Indoor machine room installation
High ambient locations
Coastal or corrosive environments
Noise-sensitive sites
Choose by Technical Requirements
냉매: R404A / R507 / R448A / R449A / R290
전압: 220V–380V-440V
Compressor brands: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
Capacity range: 1–35HP
Market-specific configuration needs
We organize our product range by operating temperature, project condition, and buyer demand. This helps distributors, 계약자, and end users identify the right series faster and shorten the path to quotation.
For Hot Regions and Outdoor Projects
Must use larger size condenser, and suits projects in the Middle East, 아프리카, Southeast Asia, and other hot climate markets (ambient temp >+43°C). We adjust the system according to ambient temperature and installation condition, so buyers can improve project suitability in demanding environments.
모델 범위: SWHCDU-01 to SWHCDU-04
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 1HP-4HP
전압: 220V 1Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: Medium temp / 저온
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
For Hot Regions and Outdoor Projects
Must use larger size condenser, suits projects in the Middle East, 아프리카, Southeast Asia, and other hot climate markets (ambient temp >+43°C). We adjust the system according to ambient temperature and installation condition, so buyers can improve project suitability in demanding environments.
모델 범위: SWHCDU-05 to SWHCDU-10
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 5HP-10HP
전압: 380V 3Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: Medium temp / 저온
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
For Hot Regions and Outdoor Projects
Must use larger size condenser, suits projects in the Middle East, 아프리카, Southeast Asia, and other hot climate markets (ambient temp > +43°C). We adjust the system according to ambient temperature and installation condition, so buyers can improve project suitability in demanding environments.
For Hot Regions and Outdoor Projects
Must use larger size condenser, suits projects in the Middle East, 아프리카, Southeast Asia, and other hot climate markets (ambient temp > +43°C). We adjust the system according to ambient temperature and installation condition, so buyers can improve project suitability in demanding environments.
모델 범위: SWHCDU-12 to SWHCDU-35
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 12HP-35HP
전압: 440V 3Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: Medium temp / 저온
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
For Chiller Rooms and Fresh Storage Projects
Support cold room projects that require stable cooling for fresh storage and chilled applications. We match each unit to room temperature, 제품로드, 전원 공급 장치, and installation conditions, so buyers can choose a system that fits practical operating requirements.
모델 범위: SWHCDU-01M to SWHCDU-04M
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 1HP-4HP
전압: 220V 1Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: Medium temp
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
For Chiller Rooms and Fresh Storage Projects
Support cold room projects that require stable cooling for fresh storage and chilled applications. We match each unit to room temperature, 제품로드, 전원 공급 장치, and installation conditions, so buyers can choose a system that fits practical operating requirements.
모델 범위: SWHCDU-05M to SWHCDU-10M
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 5HP-10HP
전압: 380V 3Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: Medium temp
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
For Chiller Rooms and Fresh Storage Projects
Our medium temperature hermetic condensing units support cold room projects that require stable cooling for fresh storage and chilled applications. We match each unit to room temperature, 제품로드, 전원 공급 장치, and installation conditions, so buyers can choose a system that fits practical operating requirements.
모델 범위: SWHCDU-12M to SWHCDU-35M
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 12HP-35HP
전압: 380~440V 3Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: Medium temp
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
For Freezer Rooms and Frozen Storage Projects
Support cold room projects that require reliable cooling for frozen storage and low temperature applications. We match each unit to room temperature (even -40°C blast freezing), product capacity and type, 전원 공급 장치, and installation conditions, so buyers can choose a system that fits demanding freezer operation.
모델 범위: SWHCDU-01L to SWHCDU-04엘
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 1HP-4HP
전압: 220V 1Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: 저온
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
For Freezer Rooms and Frozen Storage Projects
Support cold room projects that require reliable cooling for frozen storage and low temperature applications. We match each unit to room temperature (even -40°C blast freezing), product capacity and type, 전원 공급 장치, and installation conditions, so buyers can choose a system that fits demanding freezer operation.
모델 범위: SWHCDU-05L to SWHCDU-10L
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 5HP-10HP
전압: 380V 3Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: 저온
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
For Freezer Rooms and Frozen Storage Projects
Support cold room projects that require reliable cooling for frozen storage and low temperature applications. We match each unit to room temperature (even -40°C blast freezing), product capacity and type, 전원 공급 장치, and installation conditions, so buyers can choose a system that fits demanding freezer operation.
모델 범위: SWHCDU-12L to SWHCDU-35L
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 12HP-35HP
전압: 380~440V 3Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: 저온
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
대리점용, Importers, and Private Label Projects
These units support buyers who need product to match their market, brand, and project requests. We help distributors, importers, and contractors build product solutions with clearer positioning, more flexible specifications, and better purchasing efficiency.
모델 범위: SWHCDU-01O to SWHCDU-04영형
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 1HP-4HP
전압: 220V 1Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: High/Medium/Low temp
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
대리점용, Importers, and Private Label Projects
Our OEM and customized hermetic condensing units support buyers who need product configurations that match their market, brand, and project requirements. We help distributors, importers, and contractors build product solutions with clearer positioning, more flexible specifications, and better purchasing efficiency.
모델 범위: SWHCDU-05O to SWHCDU-10O
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 5HP-10HP
전압: 380V 3Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: High/Medium/Low temp
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
대리점용, Importers, and Private Label Projects
Our OEM and customized hermetic condensing units support buyers who need product configurations that match their market, brand, and project requirements. We help distributors, importers, and contractors build product solutions with clearer positioning, more flexible specifications, and better purchasing efficiency.
모델 범위: SWHCDU-12L to SWHCDU-35L
압축기 시리즈: 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요
마력 범위: 12HP-35HP
전압: 380~440V 3Phase 50/60Hz
냉매: R404A / R507 / R448A / R449A / R290
적용온도: High/Medium/Low temp
설치 유형: 집 밖의
단위 유형: Both inverter and non-inverter
치수: Based on selected model
| Brand | 중간 온도 | 저온 | High Ambient | 논평 |
|---|---|---|---|---|
| 코프랜드 | 예 | 예 | 예 | Broad application range and strong market acceptance |
| 비처 | 예 | 예 | 예 | Strong for freezer, 산업, and demanding projects |
| 댄포스 | 예 | 예 | 예, selected series | Strong for commercial refrigeration and flexible systems |
| 테쿰세 | 예 | Selected models | Limited / project-based | Better for small to mid-size commercial projects |
| 산요 | Selected models | Selected models | Project-based | Confirm model range and local support first
|
알아채다: Other brands also can suit high / 중간 / low temp request, please contact us with your detail need.
1. We Cover 1–35HP Project Demand
Our main product range spans 1–35HP, which helps buyers cover a wide range of chiller and freezer room projects. This wider range gives distributors and contractors more solutions during sourcing and project planning.
4. We Support High Ambient Projects
We support high ambient applications for buyers who work in hot and demanding climates ( abmient temp >+43°C). This matters for outdoor projects in regions where standard system don’t match the real operating environment, must use large size condenser and compressor.
2. We Support Multiple Refrigerant Options
We support R404A, R507, R448A, R449A, and R290 for different application and market needs. Buyers can align refrigerant choice with project conditions, market expectations, and future product positioning.
5. We Support Full OEM Programs
We support full-series OEM for importers, 도매업자, and private label buyers. We confirm branding, 포장, and configuration details before production, so the final product matches the order and market plan.
3. We Offer Multiple Compressor Brand Options
We configure units with Copeland, 비처, 댄포스, 테쿰세, and Sanyo compressors according to budget, service strategy, and market preference. This helps buyers balance performance, parts availability, and commercial positioning.
6. We Offer a 3-Year Warranty and Full Inspection
We back our units with a 3-year warranty and full inspection before shipment. Clear warranty terms and full outgoing inspection help buyers reduce procurement risk and build confidence in project delivery.
The information below helps buyers make a fast initial evaluation. Final model selection should still match room size, 제품로드, 주변 온도, 냉각제, 그리고 설치조건.
| 목 | 세부 |
|---|---|
| Capacity range | 1-35HP (이상) |
| Application temperature | 고온 / Medium temp / 저온 |
| 냉매 | R404A / R507 / R448A / R449A / R290 |
| 전압 | 220V-380V-440V |
| Compressor brands | 코프랜드 / 비처 / 댄포스 / 테쿰세 / 산요 |
| 설치 | 실내 / 집 밖의 |
| High ambient support | 예 |
| OEM | Full series |
| 보증 | 3 연령 |
| 점검 | Full inspection before shipment |
The same cold room can require different systems in different climates, markets, 및 작동 조건. We recommend final confirmation based on full project data instead of a single reference factor.
We review room temperature, 방 크기, 주변 조건, 냉각제, 전압, 설치 위치, and stored product type before we recommend a model.
We support R404A, R507, R448A, R449A, and R290 according to project needs and market requirements.
We offer Copeland, 비처, 댄포스, 테쿰세, and Sanyo options based on buyer preference and application demand.
Our main product range covers 1–35HP for chiller and freezer room applications, of course we also can customize your request based on your drawing and technical data.
예. We support projects in hot regions (more than +40°C ambient temp) and recommend suitable systems according to real operating conditions.
예. We support full-series OEM, including branding, 명찰, 포장, and selected configuration adjustments.
We offer a 3-year warranty to support buyer confidence and long-term cooperation. If any quality issue, 우리는 100% solve it, if need new parts, we will delivery to you for free.
We carry out 100% inspection (in house, SGS/BV/TUV based on your request) for every unit before shipment to reduce delivery risk and support smoother installation.
We support 220V–380V-440V according to project requirements and destination market needs.Meanwhile, supply both 50Hz and 60Hz for different coutries.
Please share room dimensions, 목표 온도, products stored, 주변 조건, 전압, 냉각제, compressor preference, installation condition, and destination country.
귀하의 브랜드 평판을 높이기 위해 저희와 협력하십시오, 고객이 평생 기억할 인상적인 경험을 얻으십시오., 경쟁 시장에서 두각을 나타낼 수 있도록 도와드립니다. !