We supply box type condensing units for cold room wholesalers, 설치자, 계약자, 최종 사용자.
Our range covers L / U / H / V Types for different installation spaces, cooling loads, and project needs.
Box type condensing unit is a compact refrigeration unit that combines the compressor, 콘덴서, 팬 모터, receiver, and basic protection components inside one cabinet. This design keeps the unit clean, 콤팩트, and easier to handle for cold room projects.
Compare with open type condensing units (semi-hermetic type), a box type design gives better component protection and a cleaner layout for transport, 설치, and site management.
Compare with monoblock units, it gives buyers more flexibility in evaporator matching and project configuration.
This type of unit fits many cold room applications, especially when buyers need standard products, easier handling, and stable batch supply for export and project use.
It works well for distributors, 설치자, 계약자, and end users who want practical selection and easier field coordination.
Good fit for
Small and medium cold rooms
Distributed refrigeration projects
Export distribution orders
Standard project supply
Projects that need easy installation and clean equipment layout
Not the best fit for
Very large centralized cold room projects
Projects with very long piping runs
Sites with poor ventilation and very high ambient heat
Applications with strict noise limits and difficult airflow conditions
The table below shows common configuration ranges for selection.
Final data depends on room temperature, 주변 온도, 냉각제, compressor brand, and target market requirements.
| 유형 | 전압 | 전원 공급 장치 | 냉각제 | 주변 온도 | 압축기 상표 | 압축기 유형 | Application Range |
|---|---|---|---|---|---|---|---|
| L Type | 220V / 380V / 415V / 460V | 1Ph / 3Ph, 50Hz / 60Hz | R404A / R507 / R448A / R449A / R290 | Standard ambient, high ambient optional | 코프랜드 / 비처 / 댄포스 / 산요 / 고도로 / customized | 스크롤 / 피스톤 | Medium temp / 저온 |
| U Type | 220V / 380V / 415V / 460V | 1Ph / 3Ph, 50Hz / 60Hz | R404A / R507 / R448A / R449A | Standard to higher ambient | 코프랜드 / 비처 / 산요 / 고도로 / customized | 스크롤 / 피스톤 | Medium temp / 저온 |
| H Type | 380V / 415V / 460V | 3Ph, 50Hz / 60Hz | R404A / R507 / R448A / R449A / R290 | Standard ambient | 코프랜드 / 비처 | 스크롤 / 피스톤 | Medium temp / 저온 |
| V Type | 380V / 415V / 460V | 3Ph, 50Hz / 60Hz | R404A / R507 / R448A / R449A | Higher ambient, tropical design optional | 코프랜드 / 비처 / customized | 스크롤 / 피스톤 | Medium temp / 저온 |
객실 크기
Target room temperature
주변 온도
Installation country
전원공급장치
Refrigerant preference
Piping route and service space
Need for evaporator or full system package
Not sure which type fits your project?
Send us your cold room size, 실온, 주변 온도, 국가, and power supply.
We will recommend the right box type condensing unit for your job.
Different cabinet structures do more than change the shape of the unit.
They affect airflow direction, service access, heat rejection, east layout, and site matching.
Buyers should choose the structure first, then confirm compressor, 냉각제, and working condition.
L Type units use a side-oriented layout that fits projects with limited installation space but still keeps practical service access. This structure works well for standard cold room and helps buyers handle batch purchasing and model selection more easily.
다음에 가장 적합
Standard chiller and freezer room projects
Regular installation locations
Standard production and shipment
Wholesale and distribution supply
Typical buyers
Cold room equipment wholesalers
Installation companies
Small and medium project buyers
모델 범위: L Series / standard box condensing unit models
압축기 시리즈: Copeland ZB / ZF / ZSI, Bitzer ECOLINE, or equivalent
압축기 유형: 스크롤 / 피스톤
마력 범위: 2HP에서 15HP로
Cooling Capacity Range: Based on working condition and refrigerant
증발 온도: 5°C ~ -35°C
적용온도: 중간 온도 / 낮은 온도
주변 온도: Up to +45°C, 높은 주변 옵션 사용 가능
전압: 220V / 380V / 415V / 460V
전원 공급 장치: 1Ph / 3Ph, 50Hz / 60Hz
냉매: R404A / R507 / R448A / R449A / R290
설치 유형: 바닥 장착형 / 집 밖의
단위 유형: Air cooled box type condensing unit
콘덴서 유형: 공냉식 핀 코일 콘덴서
팬 유형: Axial fan
제어 옵션: Basic control / control box optional
치수: 압축기 HP 및 응축기 크기에 따라 다름
Matching Use: Cold room evaporator matching available
U Type units focus more on cabinet space use and airflow layout. They fit projects that need a compact structure and balanced installation and maintenance access. This type often works well in commercial refrigeration and cold room projects with tighter space.
다음에 가장 적합
Compact installation areas
Commercial refrigeration projects
Standard and customized supply
Projects with tighter equipment layout
Typical buyers
Overseas wholesalers
Commercial refrigeration buyers
Customers with compact installation conditions
모델 범위: U Series / compact box condensing unit models
압축기 시리즈: Copeland ZB / ZF / ZS, Bitzer JE / HE, Danfoss LMZ / LLZ, or equivalent
압축기 유형: 스크롤 / 피스톤
마력 범위: 2HP to 20HP
Cooling Capacity Range: Depends on refrigerant and operating condition
증발 온도: 5°C ~ -35°C
적용온도: 중간 온도 / 낮은 온도
주변 온도: Up to +45°C, tropical design optional
전압: 220V / 380V / 415V / 460V
전원 공급 장치: 1Ph / 3Ph, 50Hz / 60Hz
냉매: R404A / R507 / R448A / R449A
설치 유형: 바닥 장착형 / outdoor or equipment area installation
단위 유형: Compact air cooled box condensing unit
콘덴서 유형: Air cooled condenser with compact cabinet layout
팬 유형: Axial fan
제어 옵션: Standard electrical parts / upgraded control box optional
치수: 압축기 HP 및 응축기 크기에 따라 다름
Matching Use: Suitable for standard cold room evaporator matching
H Type units fit projects that need clearer heat exchange arrangement and better service path design. This structure gives buyers a stronger option for engineering projects, longer running systems, and applications that need better maintenance planning.
다음에 가장 적합
Projects with higher cooling and service demands
Long running cold room systems
Engineering and customized supply
Sites that need stronger structural stability
Typical buyers
Engineering contractors
Project-based installation companies
End users who focus on stable operation
모델 범위: H Series / engineering box condensing unit models
압축기 시리즈: Copeland ZF / ZFI / ZSI, Bitzer JE / GE, Danfoss LMZ, or equivalent
압축기 유형: 스크롤 / 피스톤
마력 범위: 3HP to 30HP
Cooling Capacity Range: Depends on compressor brand and condition point
증발 온도: 0°C to -40°C
적용온도: 중간 온도 / 낮은 온도
주변 온도: Up to +45°C, high ambient version optional
전압: 380V / 415V / 460V
전원 공급 장치: 3Ph, 50Hz / 60Hz
냉매: R404A / R507 / R448A / R449A / R290
설치 유형: 바닥 장착형 / 집 밖의 / plant equipment zone
단위 유형: Air cooled box condensing unit for engineering use
콘덴서 유형: Large air cooled condenser section
팬 유형: Axial fan
제어 옵션: Expanded control and protection options available
치수: Depend on compressor HP, coil size, and cabinet design
Matching Use: Suitable for larger cold room evaporators and project systems
V Type units suit projects that need higher heat rejection efficiency and better airflow organization. This type gives strong value in hot climate markets, higher load projects, and systems that run for long hours and need stable condensing performance.
다음에 가장 적합
Projects with higher heat rejection demand
High ambient temperature countries
Heavier cooling loads
Mid-range and high-range engineering solutions
Typical buyers
Buyers in the Middle East, 아프리카, South America and Southeast Asia (tropical area)
Engineering contractors
Customers who focus on stable performance and stronger cooling output
모델 범위: V Series / high-efficiency box condensing unit models
압축기 시리즈: Copeland ZB / ZF, Bitzer ES / JE, or equivalent
압축기 유형: 스크롤 / 피스톤
마력 범위: 3HP to 40HP
Cooling Capacity Range: Depends on ambient temperature and refrigerant
증발 온도: 5°C to -40°C
적용온도: 중간 온도 / 낮은 온도
주변 온도: Up to +45°C, tropical design available
전압: 380V / 415V / 460V
전원 공급 장치: 3Ph, 50Hz / 60Hz
냉매: R404A / R507 / R448A / R449A
설치 유형: 바닥 장착형 / 옥외 설치
단위 유형: V type air cooled box condensing unit
콘덴서 유형: V coil air cooled condenser
팬 유형: Axial fan
제어 옵션: High ambient and project control options available
치수: Depend on coil design, 팬 수량, and compressor model
Matching Use: Suitable for hot climate cold rooms and higher duty systems
Many buyers choose by horsepower first. That often creates selection mistakes.
A better method starts with working condition, installation space, 주변 온도, and service access.
Choose by installation space:
If the machine area stays tight, choose a structure that uses cabinet space well and still leaves room for airflow and service access.
Choose by ambient temperature:
If the project runs in hot climates, check condenser capacity, airflow design, and high ambient configuration before you confirm the unit.
Choose by maintenance access:
If the site needs regular service and long operating hours, choose a structure that gives easier access to key components.
Choose by room temperature and cooling load:
Medium temperature and low temperature cold rooms need different compressor and refrigerant matching.
Don’t rely only on nominal HP.
Choose by project target:
Some buyers focus on first cost. Others focus on stability, easier maintenance, or repeat order consistency.
Your structure and configuration should match that target.
Quick inquiry prompt
If you send your project data, we can recommend the right type faster and reduce model mismatch.
Buyers usually contact us for one of these reasons:
They need model matching for a new project
They need a high ambient or custom power supply version
They need OEM support
They need condensing units with matching evaporators or refrigeration components
They need practical communication, not only a basic price list
We aim to support project fit, not only product supply.
You only need to send us your cold room size, 실온, 주변 온도, and installation space. We will recommend the right type based on your project instead of asking you to guess by appearance.
Start with room size, 목표실내온도, 주변 온도, installation space, and power supply. Don’t choose by horsepower only, because final selection should match real working conditions and cooling load.
Not always. Medium temperature and low temperature rooms often need different compressor matching, refrigerant selection, and condition-based capacity checks, so buyers should confirm the exact room temperature before model selection.
예. We support different voltage, phase, and frequency options for different markets. Send us your local power standard, and we will check the right configuration for you.
예. Many buyers ask for a matched evaporator and related refrigeration components to simplify procurement and reduce selection errors. This approach helps installers and contractors save communication time and improve system matching.
예. We can support OEM nameplate, label, and packaging based on your order request. If you have brand requirements, send them with your inquiry.
예. We can offer high ambient versions for hot regions (ambient temp >+43°C). Please tell us the highest outdoor temperature, so we can match the right condenser and configuration.
Depend on the model. But common components include compressor, air cooled condenser, 팬 모터, receiver, 필터, 시력 유리, and basic protection parts. We will confirm the full configuration before order.
Many box type condensing units support 220V, 380V, 415V, or 460V, with 50Hz or 60Hz options in 1 phase or 3 phase formats depending on model range. Buyers should confirm voltage, phase, and frequency before quotation because power mismatch can block installation and startup.
Check room temperature, 주변 온도, 전원 공급 장치, 냉각제, installation space, ventilation condition, and whether the project needs standard configuration or custom options. Buyers should also confirm what the standard unit includes, what optional parts are available, and whether the supplier supports technical documents, OEM, and after-sales communication.
귀하의 브랜드 평판을 높이기 위해 저희와 협력하십시오, 고객이 평생 기억할 인상적인 경험을 얻으십시오., 경쟁 시장에서 두각을 나타낼 수 있도록 도와드립니다. !
우리는 귀하의 아이디어나 제안을 바탕으로 우수한 냉동 제품을 맞춤화합니다. 2010