1. Must use R410a dedicated tools, accessories, en materialen, mustn’t use R22’s as a substitute.

2. If any refrigerant leak during operation, please ventilate in time. Because if the refrigerant leaks indoor, once it comes into contact with the electric sparks emitted by electric fans, heaters, electric stoves and other appliances, will form toxic gases.

3. When install or move the airco, strictly forbidden to mix air other than R410a refrigerant into the refrigerant circulation system. When air and other gas mixed into the system, the high pressure of the refrigerant circulation system will be abnormal, which is the main cause of the rupture and cracks of the whole system.

4. Don’t mix with other refrigerant or refrigeration oil; anders, airco will not cool/heat, the compressor lubrication will deteriorate, generate heat, and even burn out.

R410a Koelmiddel

R410a Moisture and Residue

1. R410a compressor (using POE oil), POE oil has stronger water absorption than mineral oil (R22 compressor). When the moisture content of the system exceeds the standard, water will react chemically with POE to generate acid and water, forming a vicious cycle, will destroy the system, generate impurities and copper plating, form sludge, which is the main causes of dirty and oil blockage.

2. Compressor which rubber plug is detached, cann’t be used!

3. When install the outdoor unit, after pulling out the compressor rubber plug, please don’t leave it for a long time (<10minuut), and try best to shorten the welding and sealing time of the system (<15minuut).

4. When vacuuming, ensure the vacuum degree is < -0.1MPa.

5. Strictly forbidden to leave residues or mix impurities and dust in the system; anders, it will block the system, which is one main causes of dirty and oil blockage.

Bell mouth, Nut, Bending Radius

Bell mouth size

Bell Month Size D:(mm), OD=Outer Diameter

 

Copper tube protrusion

Copper tube protrusion A:(mm)

 

Nut size

Nut size B:(mm)

 

Pipe bending radius

Pipe bending radius R: (mm)

Vacuum

Vacuuming

Vacuum Method

R410a Fill

Refill R410a after Partial Refrigerant Leakage

1. Must add R410a, not R22

2. Needn’t release the remaining refrigerant in the air conditioner, just add it in liquid form.

Since R410a is a near-azeotropic mixed koelmiddel, when adding it in gas form, the composition of the refrigerant will change, resulting in poor performance of the airco.

R410a Inverter Air Conditioner Charging Method

Add refrigerant in forced cooling mode!

In this mode, compressor frequency is fixed and the suction pressure is relatively stable, which makes it easier to determine whether the charge amount is appropriate.

If the frequency is not fixed, the actual frequency of the compressor is changing, and the tested pressure changes greatly. In this state, adding refrigerant is inaccurate.

Facebook
Twitteren
LinkedIn
Reddit
Afdrukken

Laat een antwoord achter

Over ons bedrijf

China Speedway-groep is een professionele HVACR-producten’ fabrikant en groothandel, we passen verschillende HVACR-producten en reserveonderdelen aan, vooral koelproducten en onderdelen. Zoals airconditioning, koelapparatuur, koude kamer oplossing, ijsmachine, ontvochtiger, elektrische motor, warmtewisselaar,koperen spoel, enz.

Zoals sindsdien op het gebied van HVACR gewerkt 2010, we hebben meer ervaringen kunnen u unieke producten en oplossingen bieden, zal ook levenslange gratis technische ondersteuning leveren. Van harte welkom onderzoek ons ​​met uw monster, tekening of ontwerp, ons doel is om uw idee waar te maken en u ervan te laten profiteren.

Bovendien, voor onze klanten, we zullen andere producten kopen, verifieer de leverancier, onderhandelen met hen met gratis kosten voor u.

Over de auteur

Foto van Vic Chung
Vic Chung

Hoi, Ik ben Vic! Begin sindsdien te werken op het gebied van HVACR 2008, onze belangrijkste producten inbegrepen: airconditioning, koude kamer koelsysteem, waterkoeler, ijsmachine, commerciële dehydrator, ontvochtiger, warmtepomp, elektrische motor, en alle toebehoren. Sinds lid geworden van China Speedway Group in 2012, Ik heb hier meer dan gewerkt 10 jaren, als algemeen directeur van de uitvoerafdeling, wij hebben vastgesteld 50+ agent in verschillende landen en gebieden.
Als onze ervaring en sterke technische ondersteuning, we kunnen uw probleem oplossen zodra u dat heeft gedaan, en onze hoofdingenieur heeft sindsdien op het gebied van HVACR gewerkt 1997. Ik ben zo trots op onze kennis die steeds populairder wordt, niet alleen voor ingenieurs, en voor HVACR zakelijke nieuwkomer, DIY-liefhebbers. Ik hoop dat je geniet van onze artikelen, als je vragen of opmerkingen hebt, stuur me dan gerust marketing op cn-beyond.com

Alle berichten

Neem contact met ons op

Vul gewoon uw e-mailadres in, telefoon en een korte beschrijving van uw vraag in dit formulier. Wij nemen binnen contact met u op 24 uur.

Neem contact met ons op

Klaar om uw project met ons te starten?

Werk met ons samen om uw merkreputatie te vergroten, krijg een indrukwekkende ervaring voor uw klanten om u levenslang te herinneren, en u helpen opvallen in de competitieve markt !

Mis de beste OEM-partner niet!

Klaar om met ons samen te werken?

Ervaar ons verschil en zet de eerste stap naar een betere toekomst voor uw bedrijf!