Come giudicare la corretta carica di refrigerante?

Sommario

Whether the refrigerant charge of apparecchiature di refrigerazione is too much or too little, it will cause facility abnormality, ad esempio: decreased cooling capacity & EER, shortened equipment life, increased input power, eccetera. So how can we judge whether the refrigerant charge is correct ?

Some commonly used judgment methods as follow:

Touch Compressor Pipeline by Hand

Everyone feels hot or cold differently. Generalmente, the human body feels hot when the temperature is >37℃, and feels cold when the temperature is <37℃. The temperature limit of skin perception is 49℃.

When you touch compressor suction and discharge pipe and feel that they aren’t cold enough, that means the refrigerant charge isn’t enough.

Touch compressor pipeline

Watch Sightglass Bubble

Bubble indicates refrigerant absence and loss of liquid line pressure. If the liquid line pressure loss is severe, the liquid refrigerant will quickly evaporate into gas. This gas will reduce refrigerant flow when flowing through the valvola di espansione (TXV) and cause its damage. If the system is not cooled enough, the pressure loss can easily cause bubbles in the sight glass.

sightglass see bubble

Test Refrigerant High-Low Pressure

In primo luogo, you must ensure both condensation air volume and evaporation air volume meet the international standard. If the two fail to match, it will directly affect the accuracy of the refrigerant pressure test.

test refrigerant high low pressure

Test Compressor Current

Compressor current will behave differently in different situations. Per esempio, it will be affected by the main power voltage value, a small deviation in voltage may cause a significant deviation in current.

Inoltre, the current is also subject to the lubrication condition of the motor bearings and changes in temperature.

Test compressor current

Calculate Superheat

Calculate superheat by measuring the suction temperature & pressure of suction pipe on the evaporatore. The pressure value is converted into temperature value, then minus suction temperature value, the difference is called superheat.

For the capillary system, measure the correct capillary flow depends on the pressure and resistance. For the expansion valve system, it is easy to overcharge. Since the expansion valve will automatically open and close.

The superheat of the expansion valve system is 7~8℃.

Surriscaldare

 

Calculate Subcooling

Calculate Subcooling by measuring the liquid temperature & pressure values ​​on the liquid pipe. The pressure value is converted into temperature value, then minus liquid temperature value, the diference is subcooling, which is equivalent to the condensation degree of the refrigerant liquid in the condenser.

If subcooling is low or non-existent, you can see the bubbles (caused by the drop in liquid pipe pressure) in the sight glass. The subcooling of the expansion valve system is 8~12℃. Subcooling degree only represents the condensation effect.

Subcooling

Calculate Inlet and Outlet Air Volume Temperature Difference

Temperature difference of air-cooled condenser is 16.7℃, and temperature difference of the evaporator is 11.1℃. Under high latent heat load, evaporatore “△twill decrease. So excessive injection, in order to obtain a higher△t”, will be detrimental to compressor operation.

Since the air volume will affect△t”, the condenser and evaporatore air volumes must be correct before measuring△t”.

Temperature gap

Suction Pipe Condensation

This method depends on the refrigerant liquid flow rate of the capillary tube and the pressure difference at both ends.

If the evaporator air volume is normal, the refrigerant flows through the evaporator according to the load change, and no frost will form. If the load decreases, the liquid refrigerant will flow through the evaporatore and enter the suction pipe.

The water vapor in the surrounding air will condense on the copper tube, iIf there is enough liquid refrigerant.

Condensation

Weigh Charge

Weighing is the most effective way to calculate refrigerant charge!

Primo, recover refrigerant, then evaculate the refrigeration system, and finally refilled by weighing.

This method is the most accurate no matter what kind of refrigeration system it is.

Weigh charge

Eventuali commenti?

Benvenuto, lascia un messaggio o ripubblicalo.

Facebook
Twitter
LinkedIn
Reddit
Stampa

lascia un commento

Riguardo la nostra compagnia

Gruppo Cina Speedway è un prodotto HVACR professionale’ produttore e grossista, personalizziamo diversi prodotti HVACR e pezzi di ricambio, in particolare prodotti e parti di refrigerazione. Come l'aria condizionata, apparecchiature di refrigerazione, soluzione per celle frigorifere, macchina del ghiaccio, deumidificatore, motore elettrico, scambiatore di calore,Bobina di rame, eccetera.

Come ha lavorato nel campo HVACR da allora 2010, abbiamo più esperienze in grado di fornire prodotti e soluzioni unici, inoltre fornirà supporto tecnico gratuito per tutta la vita. Un caloroso benvenuto alla richiesta di noi con il tuo campione, disegno o disegno, il nostro obiettivo è realizzare la tua idea e portarti benefici.

Cosa c'è di più, per i nostri clienti, forniremo altri prodotti, verificare il fornitore, negoziare con loro con addebito gratuito per te.

Informazioni sull'autore

Immagine di Vic Cheung
Vic Cheung

CIAO, Sono Vic! Inizia a lavorare nel campo HVACR da allora 2008, i nostri prodotti principali inclusi: aria condizionata, impianto di refrigerazione per celle frigorifere, refrigeratore d'acqua, macchina del ghiaccio, disidratatore commerciale, deumidificatore, pompa di calore, motore elettrico, e tutti gli accessori. Da quando è entrato a far parte del China Speedway Group nel 2012, Ho lavorato qui più di 10 anni, come il direttore generale del dipartimento di esportazione, abbiamo stabilito 50+ agente in diversi paesi e aree.
Come la nostra esperienza e un forte supporto tecnico, possiamo risolvere il tuo problema una volta che hai, e da allora il nostro ingegnere capo ha lavorato nel campo HVACR 1997. Sono così orgoglioso che la nostra conoscenza sia sempre più popolare non solo per gli ingegneri, e per il nuovo arrivato nel settore HVACR, Amanti del fai da te. Spero che ti piacciano i nostri articoli, in caso di domande o commenti, non esitare a inviarmi marketing su cn-beyond.com

Tutti i post

Contattaci

Basta inserire il tuo indirizzo email, telefono e una breve descrizione della tua richiesta in questo modulo. Ti contatteremo entro 24 ore.

Contattaci

Pronto per iniziare il tuo progetto con noi?

Collabora con noi per aumentare la reputazione del tuo marchio, ottieni un'esperienza impressionante per i tuoi clienti per ricordarti per tutta la vita, e aiutarti a distinguerti nel mercato competitivo !

Non perdere il miglior partner OEM!

Pronto a lavorare con noi?

Sperimenta la nostra differenza e fai il primo passo verso un futuro migliore per la tua azienda!