Логотип Спидвея

Поделитесь оптимальными решениями, Профессиональные знания в области HVACR и новости отрасли

Precision Air Conditioner Components List

Оглавление

Precision air conditioner refers to an air conditioner which can provide air circulation, фильтрация воздуха, охлаждение, re-heating, and temperature & humidity control to the server room.

Today we talk about precision кондиционер компоненты’ name and related terms, let’s dive in now.

Cooling Type

Air-cooled

Air cooled system includes a precision air conditioner indoor unit and a matching outdoor unit. The outdoor unit uses air for cooling, и кондиционер unit releases heat to outdoor through the outdoor unit.

Water-cooled

Water cooled system includes precision air conditioner indoor unit and cooling tower. Cooling tower provides cooling circulating water to precision air conditioner indoor unit. Air conditioner unit releases heat to outdoor through the cooling circulating water.

Chilled Water

Chiller water system includes precision air conditioner indoor unit and chiller. Chiller provides chilled circulating water to the precision air conditioner indoor unit. Кондиционер releases heat to outdoor through chilled circulating water.

Double Cold Source

Double cold source systems involved air-cooled double cold source, water-cooled double cold source and chilled water double cold source.

Air-cooled double cold source unit is based on the air-cooled unit with an additional independent chilled water coil system, the water-cooled double cold source unit is based on the water-cooled unit with an additional independent chilled water coil system, and the chilled water double cold source unit has two independent chilled water coil systems.

Free Cooling

Free cooling source systems involved two types: (1) air-cooled free cooling water host & precision air conditioner indoor unit.(2) precision air conditioner indoor unit & dry cooler.

Среди них, тип (1) precision air conditioner indoor unit is a chilled water precision air conditioner unit, and type (2) точность кондиционер indoor unit has two independent холодильные системы. The system can automatically switch between the two systems according to energy-saving conditions to achieve a balance between maximum energy-saving effect and reliable operation.

Precision air conditioner

Компонент

Компрессор

An important component of кондиционер, used to pressurize gaseous refrigerant. Common compressors used in precision air conditioner include scroll compressor and rotor compressor.

Испаритель

The main component for heat exchange in the indoor unit. The refrigerant inside absorbs heat, and the air blown over the external surface releases heat to form a heat exchange.

Конденсатор

The main component for heat exchange in the outdoor unit. The refrigerant inside absorbs heat, and the air blown over the external surface releases heat to form a heat exchange.

Ball Valve

Installed on the холодильная система pipeline to control on & off of refrigerant and act as a switch.

Фильтр-осушитель

Installed on refrigeration system pipeline to dry and filter refrigerant.

Фильтр-осушитель 1

Фильтр-осушитель

Смотровое стекло

Installed on холодильная система pipeline, used to control refrigerant amount when filling and observe refrigerant status of the system at any time.

Термостатический расширительный клапан

Installed on холодильная система pipeline to play the role of throttling and reducing pressure. Can involve into two types: thermostatic expansion valve(ТХВ) and electronic expansion valve.

Humidifier

When indoor humidity is low, device will humidify the indoor air. Humidifiers (used in precision air conditioners) are divided into: electrode humidifier and infrared humidifier.

ОбогревательWhen indoor temperature is low, the heater will heat the indoor air.Heaters for precision Кондиционеры are divided into aluminum finned heater, PTC heater and stainless steel roundplate heater.

Fan

The power equipment for air circulation inside the unit, and involved into centrifugal fan and axial fan according to direction of gasflow; involved into AC fan and EC fan according to motorspower supply form.

Low-Temp Component

A component to ensure air conditioner can still start normally when the outdoor temperature is extremely low (below -20℃)

Component Extension

For air-cooled units, when the equivalent length of the indoor unit and outdoor unit pipes exceeds 30 meter, must install the extension component on the refrigeration system pipeline. An extension component includes a check valve and a solenoid valve.

Check Valve

A device installed on the холодильная система pipeline to prevent the refrigerant from flowing back.

Соленоидный клапан

Installed on the refrigeration system pipeline to control on & off of the refrigerant and act as a switch.

solenoid valve

Соленоидный клапан

Water Leak Detector

Used to monitor whether there is a water leakage issue in the кондиционер unit.

Airflow Supply Type

It is mainly for the air outlet position and air outlet direction of the air conditioner, which is an important consideration in air conditioner selection.

Downflow Supply

Applied to server rooms with static floor (also called static pressure floor).

Air is discharged from the bottom of the кондиционер and sent under the static floor. Static floor on the air inlet side of the cabinet has holes, and the cold air flows upward to the front of the cabinet.

Cabinet absorbs the cold air to cool the electronic components, and the exhausted hot air returns to the air conditioner from air conditioner top, forming an airflow cycle.

Upflow Supply

Applied to server room with ceiling air supply or duct air supply.

Top Front Supply

Applied to small base stations in open spaces without ceiling, air duct, or static floor.

Add hood assembly to the top of the кондиционер to supply air from the upper front of the air conditioner. The cold airflow is directly sent to the front of the cabinet. The cabinet absorbs the cold air to cool the electronic components, and the exhausted hot air returns to the air conditioner from the lower front of the air conditioner, forming an airflow cycle.

Horizontal Airflow Supply

Applicable to the case where the air conditioner and the cabinet are placed side by side.

Air conditioner sends out cold air horizontally in the entire height direction, and the cold air flows to the front of the cabinet. The cabinet absorbs the cold air to cool the electronic components, and the exhausted hot air returns to the air conditioner from the back of the air conditioner, forming an airflow cycle.

airflow supply

Приложение

Raised Floor

An electrostatic floor is used in the server room. There is an elevated floor between electrostatic floor and floor for wiring, water pipes, air conditioning pipes, и т. д., making server room construction more beautiful.

Heat Load

The total amount of heat generated in the server room. This includes heat dissipation from equipment, heat transfer between walls and other maintenance structures and the outside, and heat dissipation from personnel, и т. д..

High Density Load

A single cabinet can hold many servers, and each server has high power and large heat dissipation.

Cold/Hot Aisle

Cold Hot Aisle

The cabinets in the server room are usually placed back to back or head to head. The head-to-head aisle is called cold aisle. The back-to-back aisle is called hot aisle.

Oil Trap

When the vertical height of the internal and external units exceeds 10 meter, will install an oil trap at every 6 meter vertical height of the air pipe so that the oil can smoothly return to the compressor for lubrication.

Заключение

We talked about main components and their functions about precision air conditioner, also cooling type, airflow type, application about precision air conditioning.

Then you will know they are essential for the whole air conditioning system, precision air conditioners are critical for maintaining stable environmental conditions in sensitive applications like data center, лаборатория, and telecom facility. Their ability to provide precise temperature, humidity control, and efficient operation ensures the reliability and lifespan of critical equipment.

Любые комментарии?

Добро пожаловать оставьте сообщение или сделайте репост.

Фейсбук
Твиттер
LinkedIn
Реддит
Распечатать

оставьте ответ

О нашей компании

Китайская группа по спидвею это профессиональные продукты HVACR’ производитель и оптовик, мы настраиваем различные продукты HVACR и запасные части, особенно холодильные продукты и детали. Например, кондиционер, холодильное оборудование, решение для холодной комнаты, Генератор льда, осушитель, электрический двигатель, теплообменник,медная катушка, и т. д..

Как работал в области HVACR с тех пор 2010, у нас больше опыта, мы можем предоставить вам уникальные продукты и решения, также будет предоставлять бесплатную техническую поддержку в течение всего срока службы. Тепло приветствуем запрос с вашим образцом, рисунок или дизайн, наша цель - воплотить вашу идею в жизнь и принести вам пользу.

Что еще, для наших клиентов, мы будем источник других продуктов, проверить поставщика, вести переговоры с ними бесплатно для вас.

Об авторе

Картинка Вик Чунг
Вик Чунг

Привет, я Вик! Начать работу в сфере HVACR с 2008, наши основные продукты включены: кондиционер, система охлаждения холодильной камеры, охладитель воды, Генератор льда, коммерческий дегидратор, осушитель, Тепловой насос, электрический двигатель, и все аксессуары. С тех пор как присоединился к China Speedway Group в 2012, Я работал здесь больше, чем 10 годы, в качестве генерального менеджера экспортного отдела, мы установили 50+ Агент в разных странах и регионах.
Как наш опыт и сильная техническая поддержка, мы можем решить вашу проблему, как только у вас есть, и наш главный инженер работает в области HVACR с тех пор 1997. Я так горжусь тем, что наши знания становятся все более популярными не только среди инженеров, и для новичков в бизнесе HVACR, Любители делать своими руками. Надеюсь, вам нравятся наши статьи, если у вас есть какие-либо вопросы или комментарии, просто добро пожаловать, присылайте мне маркетинговые материалы на cn-beyond.com

Все сообщения

Связаться с нами

Просто заполните свой адрес электронной почты, телефон и краткое описание вашего запроса в этой форме. Мы свяжемся с вами в течение 24 часы.

Связаться с нами

Готовы начать свой проект с нами?

Сотрудничайте с нами, чтобы повысить репутацию вашего бренда, получите впечатляющий опыт, чтобы ваши клиенты запомнили вас на всю жизнь, и помочь вам выделиться на конкурентном рынке !

Не упустите лучшего OEM-партнера!

Готовы работать с нами?

Почувствуйте нашу разницу и сделайте первый шаг к лучшему будущему для вашего бизнеса!