Share Optimal Solutions, Professional HVACR Knowledge and Industry News

正しい冷媒充填量の判断方法?

Table of Contents

Whether the refrigerant charge of 冷凍装置 is too much or too little, it will cause facility abnormality, そのような: decreased cooling capacity & EER, shortened equipment life, increased input power, 等. So how can we judge whether the refrigerant charge is correct ?

Some commonly used judgment methods as follow:

Touch Compressor Pipeline by Hand

Everyone feels hot or cold differently. いつもの, the human body feels hot when the temperature is >37℃, and feels cold when the temperature is <37℃. The temperature limit of skin perception is 49℃.

When you touch compressor suction and discharge pipe and feel that they aren’t cold enough, that means the refrigerant charge isn’t enough.

Touch compressor pipeline

Watch Sightglass Bubble

Bubble indicates refrigerant absence and loss of liquid line pressure. If the liquid line pressure loss is severe, the liquid refrigerant will quickly evaporate into gas. This gas will reduce refrigerant flow when flowing through the 膨張弁 (TXV) and cause its damage. If the system is not cooled enough, the pressure loss can easily cause bubbles in the sight glass.

sightglass see bubble

Test Refrigerant High-Low Pressure

まずは, you must ensure both condensation air volume and evaporation air volume meet the international standard. If the two fail to match, it will directly affect the accuracy of the refrigerant pressure test.

test refrigerant high low pressure

Test Compressor Current

Compressor current will behave differently in different situations. 例えば, it will be affected by the main power voltage value, a small deviation in voltage may cause a significant deviation in current.

加えて, the current is also subject to the lubrication condition of the motor bearings and changes in temperature.

Test compressor current

Calculate Superheat

Calculate superheat by measuring the suction temperature & pressure of suction pipe on the 蒸発器. The pressure value is converted into temperature value, then minus suction temperature value, the difference is called superheat.

For the capillary system, measure the correct capillary flow depends on the pressure and resistance. For the expansion valve system, it is easy to overcharge. Since the expansion valve will automatically open and close.

The superheat of the expansion valve system is 7~8℃.

Overheat

 

Calculate Subcooling

Calculate Subcooling by measuring the liquid temperature & pressure values ​​on the liquid pipe. The pressure value is converted into temperature value, then minus liquid temperature value, the diference is subcooling, which is equivalent to the condensation degree of the refrigerant liquid in the condenser.

If subcooling is low or non-existent, you can see the bubbles (caused by the drop in liquid pipe pressure) in the sight glass. The subcooling of the expansion valve system is 8~12℃. Subcooling degree only represents the condensation effect.

Subcooling

Calculate Inlet and Outlet Air Volume Temperature Difference

Temperature difference of air-cooled condenser is 16.7℃, and temperature difference of the evaporator is 11.1℃. Under high latent heat load, 蒸発器 “△twill decrease. So excessive injection, in order to obtain a higher△t”, will be detrimental to compressor operation.

Since the air volume will affect△t”, the condenser and 蒸発器 air volumes must be correct before measuring△t”.

Temperature gap

Suction Pipe Condensation

This method depends on the refrigerant liquid flow rate of the capillary tube and the pressure difference at both ends.

If the evaporator air volume is normal, the refrigerant flows through the evaporator according to the load change, and no frost will form. If the load decreases, the liquid refrigerant will flow through the 蒸発器 and enter the suction pipe.

The water vapor in the surrounding air will condense on the copper tube, iIf there is enough liquid refrigerant.

Condensation

Weigh Charge

Weighing is the most effective way to calculate refrigerant charge!

初め, recover refrigerant, then evaculate the refrigeration system, and finally refilled by weighing.

This method is the most accurate no matter what kind of refrigeration system it is.

Weigh charge

コメント?

ようこそメッセージを残すか、再投稿してください.

フェイスブック
ツイッター
リンクトイン
レディット
印刷する

返信を残す

当社について

チャイナ・スピードウェイ・グループ プロフェッショナルな HVACR 製品です’ メーカーと卸売業者, さまざまな HVACR 製品およびスペアパーツをカスタマイズします, 特に冷凍製品と部品. エアコンなど, 冷凍装置, 冷蔵室ソリューション, 氷製造機, 除湿機, 電気モーター, 熱交換器,銅コイル, 等.

以来、HVACR分野で働いてきました 2010, 私たちはより多くの経験を持っており、独自の製品とソリューションを提供できます, また、技術サポートの生涯無料料金を提供します. あなたのサンプルでお問い合わせを歓迎します, 描画またはデザイン, 私たちの目的は、あなたのアイデアを実現し、あなたに利益をもたらすことです.

そのうえ, 私たちのクライアントのために, 他の製品を調達します, サプライヤーを確認する, あなたのための無料料金で彼らと交渉する.

著者について

の写真 ビック・チャン
ビック・チャン

やあ, 私はヴィックです! 以来、HVACR分野での作業を開始 2008, 当社の主力製品が含まれます: 空調, 冷蔵室冷凍システム, ウォーターチラー, 氷製造機, 業務用脱水機, 除湿機, ヒートポンプ, 電気モーター, とすべての付属品. 中国スピードウェイグループに参加して以来 2012, 私はここで以上の仕事をしました 10 年, 輸出部門の部長として, 私たちは確立しました 50+ さまざまな国や地域の代理店.
私たちの経験と強力な技術サポートとして, 問題が発生したら、問題を解決できます, 当社のチーフエンジニアは以来、HVACR分野で働いています。 1997. エンジニアだけでなく、私たちの知識がますます人気になっていることを誇りに思います, HVACR ビジネスの新規参入者向け, DIY愛好家. 私たちの記事を楽しんでいただければ幸いです, 質問やコメントがあれば、cn-beyond.com でマーケティングを送ってください。

すべての投稿

お問い合わせ

メールアドレスを入力するだけです, 電話番号とこのフォームでのお問い合わせの簡単な説明. 以内にご連絡させていただきます 24 時間.

お問い合わせ

私たちと一緒にプロジェクトを始める準備ができました?

私たちと提携してブランドの評判を高めてください, クライアントにあなたのことを一生覚えてもらえるような印象的な体験を提供します, 競争市場で目立つように支援します !

最高の OEM パートナーをお見逃しなく!

私たちと一緒に働く準備ができています?

私たちの違いを体験し、あなたのビジネスのより良い未来に向けた第一歩を踏み出しましょう!