Precision Air Conditioner Components List

Índice

Precision air conditioner refers to an air conditioner which can provide air circulation, filtragem de ar, resfriamento, re-heating, and temperature & humidity control to the server room.

Today we talk about precision ar condicionado componentes’ name and related terms, let’s dive in now.

Cooling Type

Air-cooled

Air cooled system includes a precision air conditioner indoor unit and a matching outdoor unit. The outdoor unit uses air for cooling, e a ar condicionado unit releases heat to outdoor through the outdoor unit.

Water-cooled

Water cooled system includes precision air conditioner indoor unit and cooling tower. Cooling tower provides cooling circulating water to precision air conditioner indoor unit. Air conditioner unit releases heat to outdoor through the cooling circulating water.

Chilled Water

Chiller water system includes precision air conditioner indoor unit and chiller. Chiller provides chilled circulating water to the precision air conditioner indoor unit. Ar condicionado releases heat to outdoor through chilled circulating water.

Double Cold Source

Double cold source systems involved air-cooled double cold source, water-cooled double cold source and chilled water double cold source.

Air-cooled double cold source unit is based on the air-cooled unit with an additional independent chilled water coil system, the water-cooled double cold source unit is based on the water-cooled unit with an additional independent chilled water coil system, and the chilled water double cold source unit has two independent chilled water coil systems.

Free Cooling

Free cooling source systems involved two types: (1) air-cooled free cooling water host & precision air conditioner indoor unit.(2) precision air conditioner indoor unit & dry cooler.

Entre eles, tipo (1) precision air conditioner indoor unit is a chilled water precision air conditioner unit, and type (2) precisão ar condicionado indoor unit has two independent sistemas de refrigeração. The system can automatically switch between the two systems according to energy-saving conditions to achieve a balance between maximum energy-saving effect and reliable operation.

Precision air conditioner

Componente

Compressor

An important component of ar condicionado, used to pressurize gaseous refrigerant. Common compressors used in precision air conditioner include scroll compressor and rotor compressor.

Evaporador

The main component for heat exchange in the indoor unit. The refrigerant inside absorbs heat, and the air blown over the external surface releases heat to form a heat exchange.

Condensador

The main component for heat exchange in the outdoor unit. The refrigerant inside absorbs heat, and the air blown over the external surface releases heat to form a heat exchange.

Ball Valve

Installed on the sistema de refrigeração pipeline to control on & off of refrigerant and act as a switch.

Secador de filtro

Installed on refrigeration system pipeline to dry and filter refrigerant.

Secador de filtro 1

Filtro Secador

Visor de vidro

Installed on sistema de refrigeração pipeline, used to control refrigerant amount when filling and observe refrigerant status of the system at any time.

Válvula de Expansão Termostática

Installed on sistema de refrigeração pipeline to play the role of throttling and reducing pressure. Can involve into two types: thermostatic expansion valve(TXV) and electronic expansion valve.

Humidifier

When indoor humidity is low, device will humidify the indoor air. Humidifiers (used in precision air conditioners) are divided into: electrode humidifier and infrared humidifier.

AquecedorWhen indoor temperature is low, the heater will heat the indoor air.Heaters for precision ar condicionado are divided into aluminum finned heater, PTC heater and stainless steel roundplate heater.

Fan

The power equipment for air circulation inside the unit, and involved into centrifugal fan and axial fan according to direction of gasflow; involved into AC fan and EC fan according to motorspower supply form.

Low-Temp Component

A component to ensure air conditioner can still start normally when the outdoor temperature is extremely low (below -20℃)

Component Extension

For air-cooled units, when the equivalent length of the indoor unit and outdoor unit pipes exceeds 30 meter, must install the extension component on the refrigeration system pipeline. An extension component includes a check valve and a solenoid valve.

Check Valve

A device installed on the sistema de refrigeração pipeline to prevent the refrigerant from flowing back.

Válvula solenoide

Installed on the refrigeration system pipeline to control on & off of the refrigerant and act as a switch.

solenoid valve

Válvula solenoide

Water Leak Detector

Used to monitor whether there is a water leakage issue in the ar condicionado unit.

Airflow Supply Type

It is mainly for the air outlet position and air outlet direction of the air conditioner, which is an important consideration in air conditioner selection.

Downflow Supply

Applied to server rooms with static floor (also called static pressure floor).

Air is discharged from the bottom of the ar condicionado and sent under the static floor. Static floor on the air inlet side of the cabinet has holes, and the cold air flows upward to the front of the cabinet.

Cabinet absorbs the cold air to cool the electronic components, and the exhausted hot air returns to the air conditioner from air conditioner top, forming an airflow cycle.

Upflow Supply

Applied to server room with ceiling air supply or duct air supply.

Top Front Supply

Applied to small base stations in open spaces without ceiling, air duct, or static floor.

Add hood assembly to the top of the ar condicionado to supply air from the upper front of the air conditioner. The cold airflow is directly sent to the front of the cabinet. The cabinet absorbs the cold air to cool the electronic components, and the exhausted hot air returns to the air conditioner from the lower front of the air conditioner, forming an airflow cycle.

Horizontal Airflow Supply

Applicable to the case where the air conditioner and the cabinet are placed side by side.

Air conditioner sends out cold air horizontally in the entire height direction, and the cold air flows to the front of the cabinet. The cabinet absorbs the cold air to cool the electronic components, and the exhausted hot air returns to the air conditioner from the back of the air conditioner, forming an airflow cycle.

airflow supply

Aplicativo

Raised Floor

An electrostatic floor is used in the server room. There is an elevated floor between electrostatic floor and floor for wiring, water pipes, air conditioning pipes, etc, making server room construction more beautiful.

Heat Load

The total amount of heat generated in the server room. This includes heat dissipation from equipment, heat transfer between walls and other maintenance structures and the outside, and heat dissipation from personnel, etc.

High Density Load

A single cabinet can hold many servers, and each server has high power and large heat dissipation.

Cold/Hot Aisle

Cold Hot Aisle

The cabinets in the server room are usually placed back to back or head to head. The head-to-head aisle is called cold aisle. The back-to-back aisle is called hot aisle.

Oil Trap

When the vertical height of the internal and external units exceeds 10 meter, will install an oil trap at every 6 meter vertical height of the air pipe so that the oil can smoothly return to the compressor for lubrication.

Conclusão

We talked about main components and their functions about precision air conditioner, also cooling type, airflow type, application about precision air conditioning.

Then you will know they are essential for the whole air conditioning system, precision air conditioners are critical for maintaining stable environmental conditions in sensitive applications like data center, laboratório, and telecom facility. Their ability to provide precise temperature, humidity control, and efficient operation ensures the reliability and lifespan of critical equipment.

Algum comentário?

Bem-vindo deixe uma mensagem ou repost.

Facebook
Twitter
LinkedIn
Reddit
Imprimir

Deixe um comentário

Sobre a nossa empresa

Grupo China Speedway é um produto HVACR profissional’ fabricante e atacadista, personalizamos diferentes produtos HVACR e peças de reposição, especialmente produtos e peças de refrigeração. Como ar condicionado, equipamento de refrigeração, solução de câmara fria, máquina de gelo, desumidificador, motor elétrico, trocador de calor,bobina de cobre, etc.

Como trabalhou na área de HVACR desde 2010, temos mais experiências podemos fornecer produtos e soluções exclusivos, também fornecerá carga vitalícia gratuita de suporte técnico. Inquérito calorosamente bem-vindo com sua amostra, desenho ou desenho, nosso objetivo é tornar sua ideia realidade e beneficiá-lo.

O que mais, para nossos clientes, iremos adquirir outros produtos, verifique o fornecedor, negocie com eles com cobrança gratuita para você.

sobre o autor

Foto de Vic Cheung
Vic Cheung

Oi, eu sou Vic! Comece a trabalhar no campo HVACR desde 2008, nossos principais produtos incluídos: ar condicionado, sistema de refrigeração de câmara fria, resfriador de água, máquina de gelo, desidratador comercial, desumidificador, bomba de calor, motor elétrico, e todos os acessórios. Desde que ingressou no China Speedway Group em 2012, Eu trabalhei aqui mais de 10 anos, como gerente geral do departamento de exportação, nós estabelecemos 50+ agente em diferentes países e áreas.
Como nossa experiência e forte suporte técnico, podemos resolver seu problema assim que você tiver, e nosso engenheiro-chefe trabalha no campo HVACR desde 1997. Estou tão orgulhoso de nosso conhecimento ser cada vez mais popular não apenas para engenheiros, e para recém-chegados de negócios HVACR, Amantes de bricolagem. Espero que esteja gostando de nossos artigos, se tiver alguma dúvida ou comentário, seja bem-vindo para me enviar marketing em cn-beyond.com

Todas as publicações

Contate-nos

Basta preencher seu endereço de e-mail, telefone e uma breve descrição da sua consulta neste formulário. Entraremos em contato com você dentro 24 horas.