Cold room is a vital device to ensure the long-term preservation of goods, and managing its internal environment is critical.
No entanto, the issue of goods becoming moldy in Quarto frio often troubles operators, damaging product quality and causing economic losses. To address this challenge, it’s essential to thoroughly understand the causes of mold growth and implement targeted preventive measures to ensure safe and efficient storage from the source.
Causes of Mold Growth
High Humidity
Humidity is one of the key factors influencing mold growth in cold room. When humidity exceeds 75%, water vapor or condensation tends to form on the goods’ superfície, creating an ideal environment for mold. The specific causes of high humidity include:
1. Poor Sealing of Cold Room
Leaks in portas, paredes, or other connections allow humid air from outside of Quarto frio to enter, aumentando a umidade interna.
2. Mau funcionamento do desumidificador
Alguma sala fria tem desumidificadores, mas se esses dispositivos forem mal conservados ou ineficientes, a umidade não pode ser controlada de forma eficaz.
3. Entrada Direta de Mercadorias com Alta Umidade
Mercadorias com alto teor de umidade, quando não pré-resfriado, liberar vapor de água dentro da câmara fria, aumentando o nível de umidade.
Controle de temperatura inadequado
O mofo cresce rapidamente em temperaturas de 5°C a 30°C. Controle inadequado de temperatura em Quarto frio cria condições ideais para a proliferação de fungos.
1. Temperatura excessiva
Falha em manter baixo temperaturas, especialmente dentro da faixa ideal para crescimento de fungos, acelerará a proliferação de fungos.
2. Flutuação de temperatura
Mudanças frequentes de temperatura causam alternância de condições de calor e frio nas mercadorias’ superfície, levando à condensação que promove o crescimento de fungos.

3. Sistema de resfriamento instável
Envelhecido ou mal conservado cooling equipment can result in uneven temperature distribution, causing localized high temperatures.
Ventilação inadequada
Proper ventilation is essential to maintain uniform environmental conditions in Quarto frio. Poor ventilation can lead to localized accumulations of humidity and temperature.
1. Overly Dense Stacking of Goods
Tightly packed goods prevent air circulation, creating areas where heat and moisture accumulate.
2. Insufficient Fan Configuration
An inadequate number of fans or improper placement leads to uneven airflow and “dead zones” where mold is more likely to thrive.
3. Faulty Ventilation
Broken ventilation systems hinder air circulation, which will cause increased humidity and temperatura.
Poor Hygiene
The hygiene of goods directly affects the likelihood of mold growth.
1. Mold on Goods’ Surfaces
Some perishable goods may already carry mold spores on their surfaces when entering Quarto frio. Without proper cleaning, these spores will proliferate.
2. Contaminated Packaging Materials
Materials such as wooden pallets and cardboard boxes easily absorb moisture, becoming breeding grounds for mold. If not treated, mold can spread from the packaging to the goods.
Insufficient Cleaning and Disinfection
If cold rooms are not cleaned and disinfected regularly, mold spores can accumulate on walls, tetos, e pisos.
1. Neglected Corners and Cracks
Mold often grows in hard-to-clean corners or cracks, which are frequently overlooked.
2. Use of Ineffective Disinfectants
Low-quality disinfectants may fail to eliminate mold spores, allowing resistant mold colonies to develop.
Improper Door Operation
Frequent or prolonged opening of portas de quarto frio allows humid and warm air to flood inside.
1. Frequent Door Use
High frequency of entry and exit disrupts the stability of the internal environment, causing sudden increases in temperature and humidity.
2. Aging Door Seals
Worn or damaged seals allow external air to seep in continuously, increasing fluctuations in humidity and temperatura.
Incorrect Structural Design of Cold Room
The design of cold room significantly impacts its operational effectiveness and resistance to mold.
1. Moisture-Absorbing Insulation
Low-quality insulation materials easily absorb water, creating a damp environment conducive to mold growth.
2. Drainage Issues
If condensation can’t be promptly drained, the floor may remain wet for long periods, fostering mold growth.

3. Poor Mold-Resistant Wall Materials
Using standard building materials instead of mold-resistant ones can lead to moldy walls, further affect stored goods.
Mold Prevention in Cold Room
Control Humidity
Maintain humidity within an appropriate range (60%~75%) is a crucial measure to prevent mold growth in Quarto frio. Specific practices include:
1. Regularly Inspect Seals
Ensure portas, paredes, and floors of the cold room are properly sealed to prevent humid air from entering. Repair or replace sealing materials promptly if any leaks.
2. Install Efficient Dehumidification Equipment
Use professional desumidificadores or air drying systems for Quarto frio, and regularly check their operational status to ensure effective dehumidification.
3. Pre-Cool Goods Before Storage
Pre-cool high-humidity goods to condense or evaporate surface and internal moisture before placing them in cold room to reduce the moisture source.
4. Monitor Humidity Levels
Install humidity sensors to monitor internal humidity in real time and adjust the dehumidification equipment accordingly.
Stabilise Temperature
Maintain a stable temperature in cold room is critical for suppressing mold growth. Effective measures include:
1.Regular Maintenance of Refrigeration Equipment
Inspect unidades de refrigeração, condensadores, e evaporadores, and clean condenser fins regularly to ensure efficient operation.
2. Set an Appropriate Temperature Range
Adjust the temperature according to the characteristics of stored goods, normally keep it below -18°C to inhibit mold growth.
3. Prevent Temperature Fluctuations
Minimize the frequency of door openings and use air curtains or rapid roll-up doors during loading and unloading to reduce the impact of temperature differences between inside and outside.
4. Zone Management
Separe mercadorias com diferentes requisitos de temperatura para evitar desequilíbrios gerais de temperatura causados por necessidades conflitantes.
Melhorar a ventilação
A ventilação adequada evita o acúmulo localizado de umidade e temperatura. As melhores práticas incluem:
1. Organize os produtos estrategicamente
Deixe espaço entre os produtos e as paredes ou pisos para permitir o livre fluxo de ar. Empilhe os itens em um padrão cruzado ou escalonado para facilitar a circulação de ar.
2. Aumente a capacidade do ventilador
Ajuste o número e a potência dos ventiladores com base no tamanho do Quarto frio para garantir que o fluxo de ar cubra todo o espaço e elimine “zonas mortas”.

3. Limpe o equipamento de ventilação regularmente
Remova periodicamente poeira e detritos de ventiladores e dutos de ventilação para manter a eficiência do equipamento.
Pré-tratar mercadorias antes do armazenamento
Reduzir os esporos de mofo trazidos para a câmara fria é fundamental:
1. Clean Goods Surface
Remove mold spores and dirt from the surface of incoming goods, particularly perishable items like fruits and vegetables.
2. Inspect Packaging Materials
Avoid using moisture-absorbent materials like wooden pallets and cardboard boxes. Opt for moisture-proof and mold-resistant plastic pallets or composite material packaging.
3. Prevent Cross-Contamination
Isolate or separately handle goods already affected by mold to prevent contamination of other items.
Regular Cleaning and Disinfection
Maintain a clean and disinfected environment in Quarto frio is essential for mold prevention:
1. Establish a Cleaning Routine
Implement a regular cleaning schedule, conduct comprehensive cleaning monthly or quarterly, and focus on neglected areas like corners, rachaduras, and door frames.
2. Use High-Quality Disinfectants
Aplicar desinfetantes antifúngicos especiais para câmaras frigoríficas de alimentos para limpar pisos, paredes, e prateleiras, garantir uma esterilização completa.
3. Seque completamente as áreas tratadas
Após a desinfecção, garantir que as áreas limpas estejam completamente secas para evitar o crescimento de mofo devido à umidade residual.
Otimize Procedimentos Operacionais
Seguir práticas operacionais adequadas reduz as flutuações de umidade e temperatura:
1. Minimize o uso da porta
Conclua as atividades de carga e descarga em uma sessão para evitar aberturas frequentes de portas.
2. Reduza o tempo de abertura da porta
Use equipamentos automatizados, como rápido roll-up doors ou cortinas de ar para minimizar a troca de ar frio e úmido.
3.Treinar pessoal
Treine a equipe para operar com eficiência durante a carga e descarga para minimizar tempos desnecessários de abertura de portas.
Melhorar o design da câmara fria
Projetar câmaras frigoríficas com a prevenção de mofo em mente minimiza os riscos:
1. Use isolamento resistente à umidade
Opte por materiais de baixa absorção de umidade, como painéis de poliuretano (Painel PU) para evitar que as camadas de isolamento fiquem úmidas e mofadas.
2. Melhorar os sistemas de drenagem
Projete inclinações do piso e canais de drenagem para remover rapidamente a condensação e limpar a água.
3. Aplicar tratamentos de parede resistentes a mofo
Use revestimentos resistentes a mofo ou filmes à prova de umidade nas paredes internas para melhorar sua resistência ao mofo.
4. Projetar circulação de ar eficaz
Simule a distribuição do fluxo de ar durante a fase de projeto para garantir que não existam áreas de acumulação persistente de calor e umidade.

Conclusão
As principais causas do crescimento de mofo em Quarto frio incluem alta umidade, impróprio temperatura controlar, ventilação inadequada, falta de higiene dos produtos, limpeza e desinfecção insuficientes, impróprio porta Operação, e projeto estrutural abaixo do ideal.
Ao implementar medidas eficazes para a gestão da humidade, estabilização de temperatura, otimização da ventilação, pre-treatment of goods, regular cleaning and disinfection, operational improvements, and structural enhancements, can effectively prevent mold growth.
This ensures the quality and safety of stored goods, reduces losses, and improves operational efficiency and reliability, ultimately providing greater value to the cold chain industry.
Algum comentário?