중국 스피드 웨이에서, we provide tailored refrigeration products solutions for our clients. This month we have client buying cold room refrigeration unit, worked for a 추운 방 project in very hot country (여름에). 알잖아, the refrigeration unit used in normal area and super hot area has very different design and configuration.
이 기사에서는, we will show you the actual example how did we work in the super high ambient temperature cold room project and keep products fresh, frozen and durable, so as a reference for customers who has the similar condition.
클라이언트 사양
Clients need to accurately control the cold room temperture ( in a large temperature scope) to keep the goods fresh, 이 콜드 룸 프로젝트에 대한 세부 사항은 다음과 같습니다.
국가: Saudi Arabia
주변 온도: Maximum 40~50°C ( 최고 60 여름에 총계, each day 8 시간)
찬 방 크기: 7 엑스 4 x 3m (길이 x 너비 x 높이)
콜드 룸 응용 프로그램: Store foods ( fresh and frozen)
Cold room set temperature: +5 ~-25°C (large temperature scope in this super high ambient temperature area)
인버터 응축 장치 위치: Outside the cold room
Evaporator unit location: Inside the cold room
콜드 룸 위치: Resenditial area
기본 솔루션
인버터 응축 장치 (실외 장치): 7HP (마력), 380V, 3위 50Hz, R404 냉매. As in summer max ambient temperature is 40~50°C, and last 60 days for maximum. So have to use bigger size condenser (use 9HP condenser but not 7HP condenser), also need a shelder to lower the temperature for condensing unit.
Inverter Condensing Unit Motherboard
그 동안에, use inverter type condensing unit can save 50% electricity FOREVER, which can save lots of money for you.
증발기 장치 (실내기): 8HP, 380V 3 phase 50Hz with electric defrosting function
찬 방 패널: 150MM 두께 PU 샌드위치 패널 0.35mm 아연 도금 강철
찬 방 문: 15010cm 높이 임계 값을 가진 MM 두께 PU 샌드위치 패널 ( 더 나은 기밀성을 위해), cold room size–2.0×0.9m (높이 x 너비). 알아채다: You also can choose 100mm thickness door, but airtightness is not good as 150mm thickess.
Backup power: Use 25kva diesel generator to avoid any sudden outage, which will spoil your goods at all.
Diesel Generator
특정 솔루션
1. Use large size condenser: Large condenser can sharply increase the cooling air volume, which can reduce the cold room temperature quicker.
2. Prepare a shelter for condensing unit ( 실외 장치), which can reduce its surface temperature.
Condensing Unit Shelter
3. 220V 50Hz의 창 잔액을 사용하여 압력 내부 및 외부 압력 균형을 유지하십시오..
4. 실란트를 사용하여 더 나은 밀폐를 얻으십시오, because easily loss cooling air will affect your cold room cooling performance.
5. Prepare a plastic air stripe curtain for the cold room door to avoid any cooling air waste.
6. Use LED display screen board for inverter condensing unit to monitor the cold room temperature in REAL TIME.
LED Display Screen Board for Inverter Condensing Unit
7. 한두 개의 LED 차가운 방광을 사용하여 차가운 방 안에 빛을 명확하게 유지하십시오..
8. Make a hole then install the floor drain on the floor panel, in order to clear and drainage all the waste water inside the cold room.
맞춤형 콜드 룸 솔루션이 필요합니다?
At “CHINA SPEEDWAY”, 우리는 다양한 응용 프로그램을위한 맞춤형 콜드 룸 솔루션을 제공하는 전문가입니다..
실온은 +15 ~ -40 ° C 일 수 있습니다 (For some special condition can be -70°C), 또 다른 특수 온도가 필요한 경우, 그에 따라 모든 요구 사항을 보여줄 수 있습니다.
우리는 구체적으로 설치하고 콜드 룸 패널 어셈블리를위한 도면을 제공하는 방법을 지원할 것입니다., 한편 콜드 룸에 대한 모든 팁을 제대로 작동하고 더 긴 수명을 지속하십시오..
자세한 내용은 저희에게 연락하거나 특정 요구 사항에 대해 논의하십시오.. 우리는 고품질로 시스템을 최적화하는 데 도움이되기를 기대합니다., 정밀 엔지니어링 콜드 룸 솔루션.